PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE For use in GB and IE 10/07 EINS 513502 CONTENTS SECTION PAGE INSTALLATION SECTION 3 INSTALLATION 4 TECHNICAL DATA 5 FITTING AND PRODUCT DIMENSIONS 6 ELECTRICAL CONNECTION 7-8 CONNECTING TO GAS 9-11 COOKER STABILITY 11 LEVELLING & MOBILITY WHEELS 12 FITTING OF HOTPLATE CASTING & PAN SUPPORTS 13-16 SPLASHBACK 17 USERS GUIDE 18 GENERAL INFORMATION 19 HEALTH & SAFETY 20 PRODUCT VIEW 21 CONTROL PANEL 22 SETTING UP THE COOKER FOR USE 23 GAS HOTPLATE 24-25 TO FIT PAN SUPPORTS 26 ASSEMBLY OF BURNERS 27-28 THE GRILL 29 THE OVENS 30 HOW TO USE THE OVEN SHELVES 31 OVEN COOKING GUIDE 32 CONVENTIONAL OVEN COOKING 33-34 FAN OVEN COOKING 35-36 THE AUTOMATIC COOKING CONTROL 37 SETTING THE AUTOMATIC COOKING CONTROL 38 SETTING THE MINUTE TIMER 39 CLEANING & CARING 40-42 SERVICING SECTION 43 SERVICING 42-52 WIRING DIAGRAM 53 2 Installation Section Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Aga. 3 INSTALLATION WARNING: THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH THE REGULATIONS IN FORCE AND ONLY USED IN A WELL VENTILATED SPACE, READ THE INSTRUCTIONS BEFORE INSTALLING OR USING THIS APPLIANCE. PRIOR TO INSTALLATION, ENSURE THAT THE LOCAL DISTRIBUTION CONDITIONS (TYPE OF GAS AND GAS PRESSURE) AND THE ADJUSTMENTS OF THE APPLIANCE ARE COMPATIBLE. THE ADJUSTMENT CONDITIONS FOR THIS APPLIANCE ARE STATED ON THE DATA PLATE WHICH IS SITUATED IN THE CENTRE VENT SLOT AT THE BASE OF THE APPLIANCE. This appliance is not connected to a combustion products evacuation device. It must be installed and connected in accordance with current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation. (B.S. 5440 Part 2). It should be in accordance also with any relevant requirements of the Gas Region and Local Authority. In your own interest, and that of safety to comply with the law, all gas appliances must be installed by a competent person. Failure to install appliances correctly could lead to prosecution. On completion, test the gas installation for tightness. WARNING: THIS APPLIANCE MUST BE EARTHED. The appliance is designed for the voltage stated on the data plate. The Four-Two is supplied from the manufacturers as a fully tested chassis construction. Hot plate, doors, splashback, pan supports and handrail are assembled during installation. 4 TECHNICAL DATA HOTPLATE NATURAL GAS G20 - (APPLIANCE CATEGORY I2H) L.H.F. R.H.F. R.H.R. L.H.R. WOK BURNER TYPE ULTRARAPID RAPID SEMI-RAPID RAPID MAXIMUM HEAT 4.5 kW 3.0 kW 3.0 kW 1.75 kW INPUT INJECTOR MARKING INNER 0.66 116 116 097 OUTER 1.00 --- PRESSURE POINT POSITION: LEFT HAND REAR 1.75 kW INJECTOR PRESSURE SETTING: 20mbar - NG BURNER IGNITION: H.T. SPARK G30/G31 - (APPLIANCE CATEGORY I3+) L.H.F. R.H.F. R.H.R. L.H.R. WOK BURNER TYPE ULTRA-RAPID RAPID SEMI-RAPID RAPID MAXIMUM HEAT 4.0 kW 3.0 kW 3.0 kW 1.75 kW INPUT (287 g/h) (215 g/h) (215 g/h) (125 g/h) INJECTOR MARKING INNER 0.46 85 85 65 OUTER 0.66 -- PRESSURE POINT POSITION: LEFT HAND REAR 1.75 kW INJECTOR PRESSURE SETTING: PROPANE (G31) - 37 mbar BUTANE (G30) - 28 mbar BURNER IGNITION: H.T. SPARK ELECTRIC GRILL AND OVENS TOP OVEN POWER RATING - 2.2 kW GRILL ELEMENT - POWER RATING 2.25kW LOWER OVEN (FAN) - 2.0kW TOTAL OUTPUT - 4.2 kW 230V 30 AMP POWER SUPPLY This is a CLASS 1, type X appliance. The data plaque is located on a pull out plate - lower front of appliance (See Fig. 10, Page 21). WEIGHT OF APPLIANCE : 140 kg 5 FITTING AND PRODUCT DIMENSIONS Any side wall above the cooker on either side shall be not less than 60mm horizontally from the cooker (Fig. 1). Surfaces over the top of the cooker must not be closer than 650mm. The vent slots in the back of the top plate must not be obstructed. DESN 513504 Fig. 1 6 ELECTRICAL CONNECTION ELECTRICAL CONNECTION IS LOCATED AT THE TOP RIGHT HAND SIDE OF THE APPLIANCE, BEHIND SIDE PANEL. DURING INSTALLATION REMOVE THE RIGHT HAND SIDE PANEL TO CONNECT ELECTRICAL SUPPLY. Remove 6 screws securing side panel to gain access to mains terminal. See Fig. 3 for location of cover. Remember that the mains electrical cable must be routed through the grommet at the rear right hand side of the cooker near the top, before connecting to the mains terminal connection. REFER TO FIG. 2 for wire connection to appliance. Remember that an excess of cable length is required inside the cooker to allow for possible servicing of the spark generator. Remember that an excess of cable length is required behind the cooker for the withdrawal of the cooker from between the kitchen units etc. SINGLE PHASE CONNECTION -The cooker requires a 30amp power supply fitted in conjunction with a double pole isolator with a minimum contact clearance of 3mm and be connected to the mains with a minimum 6mm2 cable to comply with th...