4.7 PGM304-1, PGM365-1 aacan The Life of the Kitchen.® Revised 06/24/08 30", 36", 46" Wide, Preference™ Gas Cooktops 2/2 PLANNING GUIDE All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted. T 1/4” (6 mm) Mimimum clearance to combustible surfaces Under Cabinet Clearances (Front View) “B” Model Minimum PGM304-1 29” (737 mm) PGM365-1 35 1/4” (895 mm) “A” “A” Model Minimum Recommended PGM304-1 30” (762 mm) 36” (914 mm) PGM365-1 36” (914 mm) 42” (1067 mm) Dedicated Total Approximate Circuit Connected Gas Supply Shipping Model No. Required Load Requirements Weight PGM304-1 120 Vac, 60 Hz, 15 Amp (Breaker) 0.03 kW (0.25 Amp) 1/2” (13 mm) Regulator -Natural Gas Standard 53 lbs. PGM365-1 3/4” (19 mm) Regulator -Natural Gas Standard 67 lbs. [HI NOTES: 1. Factory installed propane (LP) special ordered. 2. Cooktop is supplied with a 40” (1016 mm) power cord, with a three-prong grounded plug. 3. Utilities connections are located on the bottm of the chassis at the right rear corner of the cooktop. 4. See the Combination Installation (CI) section if installing with a downdraft, wall oven, or warming oven. Web: Corporate Phone: 800-793-0093 Specifications are subject to change without notice. See installation instructions for additional details. 4.8...