manual abstract


non-abrasive (liquid) cleaning agent. To keep the soleplate smooth, avoid hard contact with metal objects. Never use a scouring pad, vinegar or other chemicals to clean the soleplate. 4 5 The iron is There is a connection Check the mains cord, the plug and Clean the upper part of the iron with a damp cloth. plugged in, but problem. the wall socket. the soleplate is Regularly rinse the water tank with water. Empty the water tank after you cold. have rinsed it (Fig. 12). Double-Active Calc System (specific types only) The temperature dial is Set the temperature dial to the set to MIN. required position. Note: See chapter ‘General description’ for the type numbers that are equipped with the Double-Active Calc System. The iron does There is not enough Fill the water tank (see chapter The Double-Active Calc System consists of an Anti-Calc tablet inside the water tank not produce any water in the water ‘Using the appliance’, section ‘Filling combined with the Calc-Clean function. steam. tank. the water tank’). -The Anti-Calc tablet prevents scale from clogging the steam vents.The tablet is constantly active and does not need to be replaced (Fig. 13). The steam control is Set the steam control to the small -The Calc-Clean function removes scale par ticles from the iron. set to position O. cloud or large cloud (see chapter ‘Using the appliance, section Calc-Clean function ‘Selecting temperature and steam Use the Calc-Clean function once every two weeks. If the water in your area is ver y setting’). hard (i.e. when flakes come out of the soleplate during ironing), use the Calc-Clean function more frequently. The steam You have used Put the iron on its heel or continue boost function the steam boost ironing in horizontal position and 1 2 3 Make sure the appliance is unplugged. does not work function too often wait a while before you use the Set the steam control to position O. properly (specific within a ver y shor t steam boost function again. types only). period. Fill the water tank to the maximum level. Do not pour vinegar or other descaling agents into the water tank. The iron is not hot Set an ironing temperature at which enough. the steam boost function can be 4 5 6 7 8 Set the temperature dial to MAX (Fig. 14). used ( 3 to MAX). Put the Put the mains plug in an earthed wall socket. iron on its heel and wait until the temperature light goes out before Unplug the iron when the temperature light goes out. you use the steam boost function. Hold the iron over the sink and turn the steam control to the Calc-Clean position . (Fig. 15) Flakes and Hard water forms Use the Calc-Clean function one or x impurities come flakes inside the more times (see chapter ‘Cleaning Pull the steam control slightly upwards and gently shake the iron until all water out of the soleplate. and maintenance’, section ‘Calc in the tank has been used up (Fig. 16). soleplate during Clean function’). Steam and boiling water come out of the soleplate. Scale (if any) is flushed out. ironing. ,9 After you have used the Calc-Clean function, press down the steam control while you turn it to position O. (Fig. 17) The automatic shut-off Pick up the iron or move it slightly function has been to deactivate the automatic shut-off Note: Repeat the Calc-Clean process if the water that comes out of the iron still contains activated (see chapter function.The automatic shut-off light scale particles. ‘Features’, section goes out. After the Calc-Clean process ‘Automatic shut-off ’). 1 2 3 4 Put the plug in the wall socket and let the iron heat up to let the soleplate dry. Water droplets You have not closed Press the cap until you hear a click. drip on the fabric the cap of the filling Unplug the iron when the temperature light goes out. during ironing. opening properly. Move the iron gently over a piece of used cloth to remove any water stains that may have formed on the soleplate. The set temperature Set an ironing temperature that is is too low for steam suitable for steam ironing ( 2 to Let the iron cool down before you store it. ironing. MAX). Put the iron on its heel and Cleaning the steam control needle wait until the temperature light goes out before you star t ironing. 1 2 Pull the steam control out of the appliance. (Fig. 18) You have put an Rinse the water tank and do not put Use vinegar to remove scale, if any, from the needle (Fig. 19). additive in the water any additive in the water tank. Do not bend or damage the steam control needle. tank. 3 4 Reinsert the steam control. Place the point of the needle exactly in the centre Specific types only: you Set the temperature dial to a setting of the hole and fit the small projection on the side of the needle into the have used the steam between 3 and MAX. slot (Fig. 20). boost function at a Set the steam control to position O. setting below 3. The light on the handle flashes (specific types only). Problem Possible cause Solution Storage 1 2 3 Specific types only: you Put the iron on its heel or continue S...

Other models in this manual:
Irons - GC1930/02 (1.66 mb)
Irons - GC1905/01 (1.66 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category