Manafacture: Barco
File size: 805.87 kb
File name: 5a6e18be-016a-44ee-85ef-4e9383273646.pdf
|
manual abstract
Description R9851560 D320 Lite Digitizer 2.3 Technical summary Summary Type Value Input slots 2 input slots, front accessible, auto sensing and hot swappable Compatibility Barco LED walls Output DVI-A, Barco LED protocol R5976471 D320 LITE DIGITIZER 15/11/2006 2.Introduction Type Value Scalability no chaining, no stacking possible Flexibility User defined input Scaler 2 input channels [Data-Video] fully independent scalable to desired output resolution Z-order control Instant modification of Z-order control, for each output window Window Positioning Intuitive positioning interface Connectors RS 232 [RJ 11] — Ethernet [RJ 45] Effects Anamorphic imaging, Chroma keying [per input], Alpha keying [per input], Z-order control, Windowing/ View ports Ruggedness IP 10 Dimensions D320 Lite 486 x 482 x 53 (W x D x H) Dimensions D320 Lite input Units 41 x 181 x 103 (W x D x H) Weight ±7kg Operating Temperature 0.C<>45.C Power consumption 130 Watt max at 85–264 Volt (50–60 Hertz) R5976471 D320 LITE DIGITIZER 15/11/2006 2.Introduction 2.4 Dimensions of the D320 Lite Digitizer Dimensions 486,23 36,93 465,32 446,12 482,52 53 52 31,8 7 10 5 Image 2-2 R5976471 D320 LITE DIGITIZER 15/11/2006 2.Introduction R5976471 D320 LITE DIGITIZER 15/11/2006 3.PhysicalInstallationoftheD320LiteDigitizer 3. PHYSICAL INSTALLATION OF THE D320 LITE DIGITIZER 3.1 Installation requirements for the D320 Lite digitizer Requirements • The D320 Lite digitizer should not be placed in a built-in installation or enclosure unless proper ventilation is provided. • When using the unit in a multi unit rack assembly or closed assembly, the ambient temperature inside the assembly may not exceed the maximum rated ambient temperature of the digitizer. The installation should be such that the amount of air flow required for safe operation of the equipment is not compromised. • When building in the D320 Lite digitizer into a rack with cover door, be aware that a space of minimum 85 mm is needed between the indicated reference and the cover door. This space is needed to guide the input cables to the inputs. 85 mm • The D320 Lite digitizer will require that air flows freely in vent holes. Blocking these holes will greatly reduce the reliability of the unit and lead to the possibility of overheating. • The D320 Lite Digitizer should operate from an AC power source. The D320 Lite digitizer is equipped with an auto-ranging power supply from 85 to 264 volt (50–60 Hertz). • When installed in a rack, the mounting should be such that no hazardous condition is achieved due to uneven mechanical loading. • When the mains switch located on the back of the D320 Lite digitizer is not accessible due to rack mounting, the socket outlet supplying the rack shall be installed near the equipment and be easily accessible or a readily accessible disconnect device shall be incorporated in the fixed wiring. When using a rack in an installation it is advisable to log the serial number of the device and to activate the warranty figure by registering utilizing the included form. • Do not place the D320 Lite digitizer on an unstable cart, stand or table. The device may fall, causing personal injury and serious damage to the digitizer. • The data path between the D320 Lite digitizer and the LED display may not exceed five (5) meter. R5976471 D320 LITE DIGITIZER 15/11/2006 3.PhysicalInstallationoftheD320LiteDigitizer 3.2 Connections Rear panel inputs/outputs A B C D E FGH I Image 3-1 A LED-WALL OUTPUT B Power Switch C Power input D Not used E Retractable dust filter F COM1 : RS232 input G Not used H Not used I TCP-IP : Ethernet LAN connector • A : LED-WALL OUTPUT -LED wall out (Barco proprietary protocol). • B : Power switch -The power ON/OFF switch is provide on the rear side of the Digitizer. o Switch pressedto1=theunitstarts. o Switch pressed to 0 = unit totally switched off. • C : Power input -Autoranging from 90 to 260 VAC / 130 Watt. • D:Notused • F : Retractable dust filter -The fan intake grill of the Digitizer has a retractable dust filter. This filter can be retracted from the back of the unit. Check the filter for good functionality on a regular basis. Never allow this filter to become blocked up and never operate the unit without a good working air filter in place. • G : COM1 : RS232 input -Direct master. -RS232 input port for communication links with local PC. • H:Notused • I : Not used • J : TCP-IP : Ethernet LAN connector -For future use. 3.3 Removing and inserting a D320 Lite Digitizer input module There is no need to switch off the D320 Lite Digitizer to remove or insert an input module. The input modules are hot swappable. R5976471 D320 LITE DIGITIZER 15/11/2006 3. Physical Installation of the D320 Lite Digitizer How to remove an input module from the D320 Lite Digitizer 1. Push in the release button underneath the input module which you want to remove. At the same time pull out the input module by the grip handle. (image 3-2) 1 2 Image 3-2 How to insert an input module into...