(Degraded, Failed, Not_Present) Cage cage: "Power supply AC state is
<СОСТОЯНИЕ_БЛОКА_ПИТАНИЯ>" Cage cage: "Cage is in 'servicing' mode (Hot-Plug LED may be
illuminated)" Cage cage: "Firmware is not current"
Пример 1 для кожуха
Component -------------Description-------------- Qty Cage Cages missing A loop 1 Cage SFPs with
low receiver power 1 Component -Identifier- --------Description------------------------ Cage cage:4
Missing A loop Cage cage:4 Interface Card 0, SFP 0: Receiver Power Low: Check FC Cable
Рекомендуемое действие 1 для кожуха
Проверьте подключение/путь к SFP в кожухе и уровень приема сигнала в SFP. Показание
мощности RX менее 100 мкВт сигнализирует о состоянии низкого уровня мощности RX; типичные
показания находятся в диапазоне 300–400 мкВт. Полезные команды интерфейса командной
строки: showcage -d и showcage -sfp ddm.
Для кожухов дисков ожидается по меньшей мере два подключения, и если это не так, то
отмечается исключение.
cli% showcage -d cage4 Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side 4 cage4 ---
0 3:2:1 0 8 28-36 2.37 2.37 DC4 n/a -----------Cage detail info for cage4 --------- Fibre Channel Info PortA0
PortB0 PortA1 PortB1 Link_Speed 0Gbps -- -- 4Gbps ----------------------------------SFP
Info----------------------------------- FCAL SFP -State- --Manufacturer-- MaxSpeed(Gbps) TXDisable
TXFault RXLoss DDM 0 0 OK FINISAR CORP. 4.1 No No Yes Yes 1 1 OK FINISAR CORP. 4.1 No No No Yes Interface
Board Info FCAL0 FCAL1 Link A RXLEDs Off Off Link A TXLEDs Green Off Link B RXLEDs Off Green Link B TXLEDs Off
Green LED(Loop_Split) Off Off LEDS(system,hotplug) Green,Off Green,Off -----------Midplane Info-----------
Firmware_status Current Product_Rev 2.37 State Normal Op Loop_Split 0 VendorId,ProductId 3PARdata,DC4 Unique_ID
1062030000098E00 ... -------------Drive Info------------- ----LoopA----- ----LoopB----- Drive
NodeWWN LED Temp(C) ALPA LoopState ALPA LoopState 0:0 2000001d38c0c613 Green 33 0xe1 Loop fail 0xe1 OK
0:1 2000001862953510 Green 35 0xe0 Loop fail 0xe0 OK 0:2 2000001862953303 Green 35 0xdc Loop fail 0xdc
OK 0:3 2000001862953888 Green 31 0xda Loop fail 0xda OK cli% showcage -sfp cage4 Cage FCAL SFP -State-
--Manufacturer-- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM 4 0 0 OK FINISAR CORP. 4.1 No No Yes Yes 4 1
1 OK FINISAR CORP. 4.1 No No No Yes cli% showcage -sfp -ddm cage4 ---------Cage 4 Fcal 0 SFP 0
DDM---------- -Warning- --Alarm-- --Type-- Units Reading Low High Low High Temp C 33 -20 90 -25 95
Voltage mV 3147 2900 3700 2700 3900 TX Bias mA 7 2 14 1 17 TX Power uW 394 79 631 67 631 RX Power uW 0
15 794 10* 1259 ---------Cage 4 Fcal 1 SFP 1 DDM---------- -Warning- --Alarm-- --Type-- Units Reading
Low High Low High Temp C 31 -20 90 -25 95 Voltage mV 3140 2900 3700 2700 3900 TX Bias mA 8 2 14 1 17 TX
Power uW 404 79 631 67 631 RX Power uW 402 15 794 10 1259
Пример 2 для кожуха
Component -------------Description-------------- Qty Cage Degraded or failed cage power supplies
2 Cage Degraded or failed cage AC power 1 Component -Identifier- ------------Description------------
Cage cage:1 Power supply 0 is Failed Cage cage:1 Power supply 0's AC state is Failed Cage cage:1 Power supply 2 is
Off
34
Устранение неполадок


...

Other models in this manual:
Media Storage - HP 3PAR StoreServ 7400c 2-node Storage Base for Storage Centric Rack (1.45 mb)
Media Storage - HP 3PAR StoreServ 7440c 2-node Storage Base (1.45 mb)
Media Storage - HP 3PAR StoreServ 7440c 4-node Storage Base for Storage Centric Rack (1.45 mb)
Media Storage - HP 3PAR StoreServ 7200 2-node Storage Base for Storage Centric Rack (1.45 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category