manual abstract
HP StoreOnce and StoreEver Enterprise Backup Solutions (EBS) Hardware/Software Compatibility Matrix
IMPORTANT: Consult your ISV / IHV vendor's compatibility guide(s) to confirm ISV / IHV product and operating system version support details. See Page 10 & 11 for hyperlinks to partners websites.
Linux (x64 / x86)
Linux (x64 / x86)
Linux (x64 / x86) 5
Direct Attached and SAN Support
Version
Direct Attached and SAN Support
Version
Direct Attached and SAN Support
Version
Operating Systems
16Gb Fibre Channel Host Bus Adapters (HP Branded / Third Party)
4Gb Fibre Channel Host Bus Adapters 6 (HP Branded / Third Party)
RHEL [AS/ES/WS] 6 (x64 / x86) 1
Update 4
SN1000Q (QW971A, QW972A) (PCI-e)
FC1142SR (AE311A) / QLogic QLE2460 & FC1242SR (AE312A) / QLogic QLE2462 (PCI-e)
RHEL [AS/ES/WS] 5 (x64 / x86) 1, 2
Update 10
FW
7.02.00
FW
5.03.15
SLES 11 (x64 / x86)
SP2
RHEL 5 FC driver 4
8.06.00.03.5.6-k2
RHEL 5 FC driver 10
8.06.00.03.5.6-k2
SLES 10 (x64 / x86) 2
SP4
RHEL 6 FC driver
8.06.00.03.06.0-k
RHEL 6 FC driver
8.06.00.03.06.0-k
Servers
SLES 10 FC driver
8.04.00.09.10.3-k2
SLES 10 FC driver
8.04.00.06.10.3-k
HP ProLiant & BladeSystem c-Class
SLES 11 FC driver
8.06.00.03.11.1-k
SLES 11 FC driver
8.06.00.03.11.1-k
Third Party
SN1000E (QR558A/QR559A) (PCI-e)
FC2142SR (A8002A) / Emulex LPe1150 & FC2242SR (A8003A) / Emulex LPe11002 (PCI-e)
10GbE Converged Network Adapters (HP Branded)
FW
1.1.62.0
FW
2.82x4
CN1000E (AW520A) (PCI-e)
iSCSI support only
RHEL 5 FC driver 4
8.2.2.33
RHEL 5 FC driver 10, 13
8.2.2.33
CN1000Q (BS668A) / 526FLR (629138-B21) (PCI-e)
RHEL 6 FC driver
8.3.7.39
RHEL 6 FC driver
8.3.7.39
FW 3
4.14.25(OOB)
SLES 10 FC driver
8.2.0.145.4p
SLES 10 FC driver
8.2.0.145.4p
RHEL 5 FC driver 4
8.06.00.03.5.6-k2
SLES 11 FC driver
8.3.7.39
SLES 11 FC driver
8.3.7.39
RHEL 6 FC driver
8.06.00.03.06.0-k
SN1100E (C8R38A/C8R39A) Emulex (LPe16000B/LPe16002B) (PCI-e)
41B (AP767A/B) / Brocade 415 & 42B (AP768A/B) / Brocade 425 (PCI-e)
SLES 10 FC driver
8.04.00.06.10.3-k
FW
1.1.62.0
FW
3.2.1.0(OOB)
SLES 11 FC driver
8.06.00.03.11.1-k
RHEL 5 FC driver 4
8.2.2.33
RHEL 5 FC driver 10
3.2.1.0(OOB)
RHEL 5,6, SLES 10,11 NIC Driver
5.2.46.4-2
RHEL 6 FC driver
8.3.7.39
RHEL 6 FC driver
3.2.1.0(OOB)
RHEL 5,6, SLES 10,11 iSCSI Driver
5.04.01.05.05.07-1
SLES 10 FC driver
8.2.0.145.4p
SLES 10 FC driver
3.2.1.0(OOB)
CN1100E (BK835A) (PCI-e) / 554FLR (FlexibleLOM, 629142-B21)
SLES 11 FC driver
8.3.7.39
SLES 11 FC driver
3.2.1.0(OOB)
FW 3
4.9.311.20
16Gb HP BladeSystem c-Class Fibre Channel Host Bus Adapters
FC1143 (AB429A) / QLogic QLA2460 & FC1243 (AE369A) / QLogic QLA2462 (PCI-X 2.0)
RHEL 5 FC driver 4
8.2.2.33
QMH2672(710608-B21) (PCI-e)
FW
5.03.15
RHEL 6 FC driver 5
8.3.7.39
FW
7.02.00
RHEL 5 FC driver 10
8.06.00.03.5.6-k2
SLES 10 FC driver
8.2.0.145.4p
RHEL 5 FC driver 4
8.06.00.03.5.6-k2
RHEL 6 FC driver
8.06.00.03.06.0-k
SLES 11 FC driver (Only supported with SP1)
8.3.7.39
RHEL 6 FC driver
8.06.00.03.06.0-k
SLES 10 FC driver
8.04.00.06.10.3-k
RHEL 5,6, SLES 10,11 NIC Driver
4.9.311.1-1
SLES 10 FC driver
8.04.00.09.10.3-k2
SLES 11 FC driver
8.06.00.03.11.1-k
RHEL 5,6, SLES 10,11 iSCSI Driver
4.9.196.1007-1
SLES 11 FC driver
8.06.00.03.11.1-k
FC2143 (AD167A) / Emulex LP1150 & FC2243 (AD168A) / Emulex LP11002 (PCI-X 2.0)
CN1100R (QW990A) (PCI-e) / 534FLR (700751-B21)
8Gb Fibre Channel Host Bus Adapters (HP Branded / Third Party) 6
FW
2.82x4
FW 3
7.8.24
81Q (AK344A) / QLogic QLE2560 & 82Q (AJ764A) / QLogic QLE2562 (PCI-e)
RHEL 5 FC driver 10, 13
8.2.2.33
RHEL 5 FC driver 4
FW
7.02.00
RHEL 6 FC driver
8.3.7.39
RHEL 6 FC driver 5
2.3.10 (OOB)
RHEL 5 FC driver 7
8.06.00.03.5.6-k2
SLES 10 FC driver
8.2.0.145.4p
SLES 10 FC driver
RHEL 6 FC driver
8.06.00.03.06.0-k
SLES 11 FC driver
8.3.7.39
SLES 11 FC driver (Only supported with SP1)
2.3.10 (OOB)
SLES 10 FC driver
8.04.00.06.10.3-k
4Gb HP BladeSystem c-Class Fibre Channel Host Bus Adapters 6
RHEL 6, SLES 11 NIC Driver
7.10.7-1
SLES 11 FC driver
8.06.00.03.11.1-k
LPe1105 (403621-B21) (PCI-e) for HP BladeSystem c-Class
RHEL 6, SLES 11 iSCSI Driver
0.7.8.1e-1
81E (AJ762A & AJ762B) / Emulex LPe12000 & 82E (AJ763A & AJ763B) / Emulex LPe12002
FW
2.82x4
10GbE HP BladeSystem Converged Network Adapters (HP Branded)
FW
2.01a12
RHEL 5 FC driver 10
8.2.2.33
NC551m (580151-B21) & NC551i (PCI-e)
iSCSI support only
RHEL 5 FC driver 7
8.2.2.33
RHEL 6 FC driver
8.3.7.39
NC553m (613431-B21) / NC553i / 554M (647590-B21) / 554FLB (647586-B21) (PCI-e)
RHEL 6 FC driver
8.3.7.39
SLES 10 FC driver
8.2.0.145.4p
FW 3
4.9.311.20
SLES 10 FC driver
8.2.0.145.4p
SLES 11 FC driver
8.3.7.39
RHEL 5 FC driver 4
8.2.2.33
SLES 11 FC driver
8.3.7.39
QMH2462 (403619-B21) (PCI-e) for HP BladeSystem c-Class
RHEL 6 FC driver
8.3.7.39
81B (AP769A & AP769B) / Brocade 815 & 82B (AP770A & AP770B) / Brocade 825 (PCI-e)
FW
5.03.15
SLES 10 FC driver
8.2.0.145.4p
FW
3.2.1.0(OOB)
RHEL 5 FC driver 10
8.06.00.03.5.6-k2
SLES 11 FC driver (Only supported with SP1)
8.3.7.39
RHEL 5 FC driver 7
3.2.1.0(OOB)
RHEL 6 FC driver
8.06.00.03.06.0-k
RHEL 5,6, SLES 10,11 NIC Driver
4.9.311.1-1
RHEL 6 FC driver
3.2.1.0(OOB)
SLES 10 FC driver
8.04.00.06.10.3-k
RHEL 5,6, SLES 10,11 iSCSI Driver
4.9.196.1007-1
SLES 10 FC driver
3.2.1.0(OOB)
SLES 11 FC driver
8.06.00.03.11.1-k
NC534M (700748-B21) / 534FLB (700741-B21) (PCI-e)
SLES 11 FC driver
3.2.1.0(OOB)
SAS - Third Party HBAs and Integrated Controllers
FW 3
7.8.24
8Gb HP BladeSystem c-Class Fibre Channel Host Bus Adapters 6
LSI 9212-4i4e (6Gb, PCI-e) 12
RHEL 5 FC driver 4
QMH2572 (651281-B21) / QMH2562 (451871-B21) (PCI-e) for HP BladeSystem c-Class
SAS Host Bus Adapters and Controllers
RHEL 6 FC driver
2.3.10 (OOB)
FW
7.02.00
P721m, P731m16 (6Gb, PCI-e) for BL Gen8 servers only
SLES 10 FC driver
RHEL 5 FC driver 7
8.06.00.03.5.6-k2
P222, P430, P4205, P431, P421, P822, H220, H221, H222
(6Gb, PCI-e)
SLES 11 FC driver (Only supported with SP1)
2.3.10 (OOB)
RHEL 6 FC driver
8.06.00.03.06.0-k
P212, P4108, P411, P711m, P712m, P812 (6Gb, PCI-e)
RHEL 5,6, SLES 10,11 NIC Driver
7.10.7-1
SLES 10 FC driver
8.04.00.06.10.3-k
P700m, P800, SC44Ge (3Gb, PCI-e)
RHEL 5,6, SLES 10,11 iSCSI Driver
0.7.8.1e-1
SLES 11 FC driver
8.06.00.03.11.1-k
SCSI Host Bus Adapters 14
NOTES:
LPe1205A (659818-B21) / LPe1205 (456972-B21) (PCI-e) for HP BladeSystem c-Class
412911-B21 (HP SC11Xe, Ultra320, PCI-e, 1 channel)
1) RHEL kernel versions include support for Oracle Enterprise Linux (OEL).
FW
2.02x6
SCSI - Third Party HBAs and Integrated Controllers 9
2) Only in-box HBA drivers and device-mapper multipathing are supported with
RHEL 5 FC driver 7
8.2.2.33
Adaptec 29320ALP-R (Ultra320, PCI-X, 1 channel)11
RHEL 5 Update 3, SLES 10 SP3 and newer.
RHEL 6 FC driver
8.3.7.39
ATTO Express PCI UL4D (Ultra320, PCI-X, 2 channel)
3) Minimum FW required for FCoE support.
SLES 10 FC driver
8.2.0.145.4p
ATTO Express PCI UL5D (Ultra320, PCI-e, 2 channel)
4) ARCserve: In RH5 when the 'udev' service is starting it will send a rewind command to any
SLES 11 FC driver
8.3.7.39
unreserved loaded tape drive in the shared SAN Environment.
804 (590647-B21) (PCI-e) for HP BladeSystem c-Class
NOTES CONTINUED
5) ARCserve: If using the Emulex OCM (One Command Manager), DO NOT enable "sensor
FW
3.2.1.0(OOB)
11) Supported with LTO-4 SCSI only
kits" during OCM installation.
RHEL 5 FC driver 7
3.2.1.0(OOB)
12) Recommended for use with HP workstations and third party servers.
6) Third Party adapters require HP drivers and firmware.
RHEL 6 FC driver
3.2.1.0(OOB)
13) LTO-5 requires Emulex inbox driver version 8.2.0.66 or newer.
7) ARCserve: In RH5 when the 'udev' service is starting it will send a rewind command to any
SLES 10 FC driver
3.2.1.0(OOB)
14) Third party servers supported with HP-branded adapters only.
unreserved loaded tape drive in the shared SAN Environment.
SLES 11 FC driver
3.2.1.0(OOB)
15) TSM and NetWorker: P212 Zero Memory HBA supported with v7.6.1.1 or later.
8) SAS Expander card 468406-B21 is required to connect external tape.
For NetWorker 7.5.4, supported with v7.5.4.6 or later.
9) Third Party SCSI HBA support is for HP servers only.
16) Not supported by SLES 10
10) ARCserve: In RH5 when the 'udev' service is starting it will send a rewind command
to any unreserved loaded tape drive in the shared SAN Environment.
Feb 2014, v1
Refer to "How to Use This Document" on pg. 3.
Page 18 of 25
...