Login:
Votes - 0, Average rating: 0 ( )

User manual HP, model HP StoreEver ESL G3 100 slot Tape Library

Manafacture: HP
File size: 203.79 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract



HP StoreEver Enterprise
CAUTION:
Parts can be damaged by
Systems Library (ESL) G3 Tape
electrostatic discharge. Keep parts in their
containers until needed. Make sure that you are
Library
properly grounded when touching static sensitive
components.
HDEM Calibration
CAUTION:
Calibration targets are in specific
Target with Magazine
locations in the library. When targets are not
in the appropriate locations, they are considered
Replacement Instructions
“out of range” and will cause calibration errors.
NOTE:
When replacing calibration targets,
make sure that the plastic rectangle is completely
Abstract
seated on the magazine.
This document describes how to remove and replace a
calibration target with magazine in a High Density
Calibration targets on the door of the HDEM
Expansion Module (HDEM) in an ESL G3 Tape Library.
are configured exactly like those on the door of
an expansion module. Please refer to the HP
StoreEver Enterprise Systems Library (ESL) G3
Tape Library Service Guide
for further
instructions if replacing a calibration target on
the door of an HDEM.
Calibration targets for the HDEM tower must be
glued-on, are white in color, and require the
HDEM Calibration Target specific FRU
(731150-001 SPS-LTO HDEM Mag
w/Calibration Target).
Inspect the contents of the kit
The kit contains one six-slot LTO magazine with
glued-on white calibration target.
Remove the existing calibration target with
magazine
NOTE:
Magazines must be removed in a
top-to-bottom order. As such, any magazines
© Copyright 2013 Hewlett-Packard Development Company, L.P.
Printed in the US
positioned vertically above the one needing
replacement must first be removed.
1.
On the operator panel, press the Robotics Enabled
button to turn off power to the picker assembly
and return it to the home position.
2.
Open the access (front) door of the HDEM.
3.
Identify the magazine(s) needing to be removed
HP Part Number: H5W99-96002
in order to access the correct calibration target,
Published: May 2013
and then remove any media from the magazines.
Edition: 1st
*H5W99-96002*
4.
Using both hands, push the magazine upwards
until it unsnaps.
5.
To remove it, pull the magazine towards you.
Page 1


...

Other models in this manual:
Media Storage - HP StoreEver ESL G3 300 slot Tape Library (203.79 kb)
Media Storage - HP StoreEver ESL G3 700 slot Tape Library (203.79 kb)
Media Storage - HP StoreEver ESL G3 1500 slot Tape Library (203.79 kb)
Media Storage - HP StoreEver ESL G3 3000 slot Tape Library (203.79 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category