Login:
Votes - 4, Average rating: 4 ( )

User manual Frymaster, model Heated Landing Zone HLZ

Manafacture: Frymaster
File size: 406.83 kb
File name: 435b3da6-36d8-49a2-95c5-29d2e7a581bc.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


By circulating heated air evenly across the open staging area, the Heated Landing Zone keeps sandwiches hot without drying or cooking. The Heated Landing Zone meets all McDonald’s standards for safety, efficiency, food safety, and cleanliness. 3.1 HLZ Installation/Setup Upon arrival, inspect the HLZ for concealed damage. Immediately report any damage to the delivering freight company. Claims must be filed within 15 days after receipt of the unit. Make sure that the unit is placed on an even surface and that the area surrounding the HLZ is free of clutter that would interfere with airflow. Install Optional Burger Bumper (Units Built Before 10/98) Optional Burger Bumper The burger bumper may be placed on either side of the HLZ to prevent pass through of product. Burger bumpers are provided by the KES. See Figure 1. Install Filter Screen (Units Built After 10/98) The filter screen is design to prevent debris from entering the computer Cowl Assembly and clogging the blower assembly. Simply fit the part on to the vent opening of the computer cowl assembly. The filter screen will snap into position. If equipped with an optional holding screw, tighten screw to pull the filter screen snug into position. Power Requirements Figure 1 Installed (before 10/98) Computer Cowl • Voltage – Two models are available: 208 VAC and 240 VAC* The filter screen snaps into place on rear of the air-intake tower. • Frequency - 60 Hz • Single Phase • 20 amp Service 3.2 HLZ Operation 1. Plug the unit into the power source. 2. See Chapter 5, Computer Operation and Programming, for proper computer setup and operation. 3. Place product in the HLZ in accordance with the restaurant’s established procedures. 4. When closing the store, remove all product from the HLZ and perform daily preventive maintenance in accordance with the MRC. Turn the computer OFF. DANGER If the 240 VAC model is operated on 208 VAC, the unit will heat slowly and may not reach maximum temperature. If the 208 VAC model is operated on 240 VAC, component damage is likely. To ensure proper operation, the power source should match the voltage on the rating plate on the bottom of the HLZ. ALL UNITS (CORD CONNECTED OR PERMANENTLY CONNECTED) SHOULD BE CONNECTED TO A GROUNDED POWER SUPPLY SYSTEM. THIS APPLIANCE IS EQUIPPED WITH A GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED INTO A PROPERLY GROUNDED RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG. 3 HEATED LANDING ZONE CHAPTER 4: HLZ MODEL/COMPONENT IDENTIFICATION Heated air flows from the air heater/blower and heat rises from the heater plate. Heater Plate Calibration Socket Air Heater Calibration Socket HLZ Computer Power Cord Heater Plate/ Landing Zone Blower Assembly Heater Plate A look at the flow of heated air around the HLZ Heater plate Air Heater 4 HEATED LANDING ZONE CHAPTER 5: COMPUTER OPERATION AND PROGRAMMING Heater Plate Temperature Switch (1) ON/OFF Switch Program Switch Air Heater Temperature Switch (4) Display Down Switch (2) Up Switch (3) HLZ Computer. 5.1 Programming Temperatures You are able to program the setpoint temperature of both the air heater and the heater plate via the computer interface. The heater plate factory default is set to the McDonald’s standard of 160°F. The air heater factory default is set to the McDonald’s standard of 220°F. If the factory default temperature settings are acceptable, skip to Section 7.2, Page 6. Ensure that the HLZ computer is in the OFF position (nothing in the display). Press , then enter 1, 2, 3, 3. Use the numerals in the upper right-hand corner of each key. Press , then , , , . The display will read SET and the LEDs on both the Heater Plate button (1) and the Air Heater button (4) will light (see previous diagram, HLZ Computer). Press the button that corresponds to the heater you wish to program. Press the Up and Down Arrow Keys to achieve the desired set-point temperature, then press the Check button once. Both heater LEDs will again light. Press or to get desired setpoint, then press to lock the temperature in. When both heaters are programmed, press again to store the programmed setpoints and exit the programming mode OR press either of the buttons (1 or 4) to change the setpoint temperature for a heater. Program as previously described. 5 HEATED LANDING ZONE CHAPTER 5: COMPUTER OPERATION AND PROGRAMMING 5.2 Operation 1. Press the power button, turning the HLZ on (the display will light and cycle through an initialization sequence). The display will read -LO- until the air heater and heater plate are within 15°F of setpoint. It will take approximately 10 minutes for the HLZ to achieve operating temperature. NOTE: A small LED will light in the display when the heater plate or air heater is energized. Press to turn on the computer. The display will read LO until both heaters are within 15° F of setpoint. R E y Heater Plate Air Heater Activation d. When the HLZ is ready for operation, the display reads R E d y (ready...

Other models in this manual:
Toasters - Heated Landing Zone HLZ (406.83 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category