Login:
Votes - 3, Average rating: 3.3 ( )

User manual LifeSource, model UA-767

Manafacture: LifeSource
File size: 217.96 kb
File name: 3dfba9e5-769a-41c6-a12c-a1ce3691a94b.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


You have purchased a LifeSource state-of-the-art blood pressure monitor, one of the most technologically advanced yet easy to use products available in the marketplace today. This LifeSource monitor is designed to make your daily regimen useful, and convenient. Physicians agree that daily self-monitoring of blood pressure is an important way individuals can contribute to maintaining their cardiovascular health and preventing the serious consequences of hypertension left undiagnosed and untreated. LifeSource has been manufacturing quality healthcare products for more than 20 years. Rest assured that we are committed to providing you and your family with monitoring devices specifically designed for high accuracy and ease of use. LifeSource—your source for a lifetime of health. LifeSource Health Line (Toll-Free): 1-888-726-9966 TABLE OF CONTENTS WHAT DISPLAY SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . .3 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . .4 HOW 767 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 BEFORE YOU START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 SELECTINGTHECORRECTCUFF . . . . . . . . . . . . . . . . . . . . . .6 TAKING YOUR BLOOD PRESSURE . . . . . . . . . . . . . . . .7 — 10 CHECK/ADJUST EXHAUST VELOCITY . . . . . . . . . . . . .11 — 12 ABOUT BLOOD PRESSURE . . . . . . . . . . . . . . . . . . . .13 — 15 BLOOD PRESSURE RECORD . . . . . . . . . . . . . . . . . . . . . . . .16 IMPORTANTINFORMATION . . . . . . . . . . . . . . . . . . . . . . .17 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . .19 ? . . LifeSource Health Line (Toll-Free): 1-888-726-9966 MONITOR COMPONENTSWHAT DISPLAY SYMBOLS MEAN ? ? WHAT DISPLAY SYMBOLS MEAN ? ? Display Condition/ Recommended Symbol Cause Action MEASUREMENT IN PROGRESS Appears during measurement; blinks and beeps when pulse is detected. Battery voltage is too low for monitor LOW BATTERY to work properly. ERROR 3 ? Appears when systolic and diastolic measurements are within 10 mmHg of each other. Appears if pressure value is unstable due to movement during reading. Appears when pressure value did not increase during cuff inflation: 1) cuff is not fastened 2) air connector is not connected properly. Remain still and refrain from talking; measurement in progress. Replace all batteries with new ones. Check for air leakage; make sure cuff tube is properly connected to monitor and exhaust rate is in increments of 2 mmHg. to 5 mmHg Try measurement again and remain very still. ERROR 2 Make sure cuff tube is properly connected to monitor, cuff is securely fastened and exhaust rate is between 2 mmHg and 5 mmHg. Make sure air connector is inserted properly into tube and monitor. TUYAU DU MONITEUR BRASSARD SYSTOLIC DISPLAY AIR SOCKET PRESSURE SWITCH DIASTOLIC DISPLAY START BUTTON MEASUREMENT IN PROGRESS LOW BATTERY DISPLAY AIR CONNECTOR TUBE UA-767 DIGITAL BLOOD PRESSURE MONITOR SYSTOLIC mmHg DIASTOLIC mmHg PUL / min 240 210 180 150 PULSE DISPLAY TM START CUFF BATTERY COMPARTMENT ADJUSTMENT SCREW BLACK PROTECTION CAP ON ADJUSTMENT SCREW LifeSource Health Line (Toll-Free): 1-888-726-9966 ? ERROR 1 LifeSource Health Line (Toll-Free): 1-888-726-9966 SELECTING THE CORRECT CUFF HOW 767 WORKS? SELECTING THE CORRECT CUFF HOW 767 WORKS? LifeSource Blood Pressure Monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillometric method” pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. The cuff is first inflated until the artery is fully blocked. Then, the monitor takes measurements while the cuff deflates. Our monitors examine the pulsatile pressure generated by the arterial wall as it expands and contracts against the cuff with each heartbeat. BEFORE YOU START You must install 4 type AA (1.5 volt) batteries and attach the cuff to the monitor before using it. To install batteries (or replace them if the “Low Battery” symbol appears on display), proceed as follows: 1. Remove battery compartment cover by gently pushing down on arrow and sliding cover forward. 2. Put in top row of batteries first. Place the batteries in compartment with positive (+) and negative (–) terminals matching those indicated in the compartment. Be sure batteries make contact with compartment terminals. 3. Replace cover by sliding it into the compartment and gently pressing into place. ? LifeSource Health Line (Toll-Free): 1-888-726-9966 Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small yields a measurement that is higher. With your arm hanging at the side of your body, measure the circumference of your upper arm at the midpoint between shoulder and elbow. ARM SIZE RECOMMENDED CUFF SIZE R...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category