Login:
Votes - 2, Average rating: 5 ( )

User manual HoMedics, model IB-BPW060A

Manafacture: HoMedics
File size: 2.87 mb
File name:
Language of manual:enes
Free link for this manual available at the bottom of the page



manual abstract


Symbols are described below and classifications follow the guidelines as described earlier in this manual (page 7). (No Symbol) 22 4. The monitor will first display the calculated average applied to the last 3 memories (“AVG. 3”). 5. Every new press of the “M” button will recall a previous reading. The latest reading will be recalled first. 23 24 RECALLING VALUES FROM MEMORY This monitor can be used by two individuals. Each user can store up to 60 measurements. 1. Press the button. 2. Choose User 1 or User 2. 3. Press the “M” button to access the memory. Original Document Name: BH-LD-01-V4 / START STOP M / START STOP M / START STOP M CLEARING VALuES fRoM MEMoRY 1. Press the button to select User 1 or User 2. 2. Press and hold the buttons at the same time while in memory recall mode and the data for the selected user will be erased automatically. STARTSTOPM 25 IMPoRTANT NoTES REGARdING YouR BLood PRESSuRE MEASuREMENT • Take your reading in a comfortable environment as measurements can be affected by hot or cold temperatures. Take your blood pressure at normal body temperature. • Do not move or talk during measurement as this can elevate readings. • Do not move or cross legs during measurement. keep feet flat on floor. • Do not touch cuff or monitor during measurement procedure. • It is suggested that you take your measurements at the same time each day and use the same wrist for consistency. • Users should wait a minimum of 5 minutes before taking additional measurements. More time may be necessary depending upon your physiology. • The measurement results that users receive are for reference only. If users have any blood pressure concerns, please consult a physician. 26 • Once inflation reaches 300 mmHg, the unit will deflate automatically for safety reasons. • This product is not suitable for people with arrhythmias. • This device may have difficulty determining the proper blood pressure for users with irregular heartbeat, diabetes, poor circulation of blood, kidney problems, or for users who have suffered a stroke. 27 CARE, MAINTENANCE & CLEANING 1. Clean the blood pressure monitor body and cuff carefully with a slightly damp, soft cloth. Do not press. Do not wash cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner. 2. Leaky batteries can damage the unit. Remove the batteries when the unit will not be used for a long time. 3. If the unit is stored near freezing, allow it to acclimate to room temperature before use. 4. This blood pressure monitor is not field serviceable. You should not use any tool to open the device nor should you attempt to adjust anything inside the device. If you have any problems with this device, please contact HoMedics Consumer Relations (contact information on warranty page). 28 5. Do not immerse the unit in water as this will result in damage to the unit. 6. Do not subject the monitor and cuff to extreme temperatures, humidity, moisture, and direct sunlight. Protect from dust. 7. Do not fold the cuff tightly. 8. Do not disassemble the monitor or cuff. If in need of repair, refer to the warranty section of this manual. 9. Do not subject the monitor to extreme shocks (do not drop on floor). 10. Do not inflate the cuff unless wrapped around wrist. 11. Do not wrap the cuff around body parts other than your wrist. 12. Do not drop or insert any object into any opening. 13. This monitor may not meet its performance specifications if stored or used outside of these temperature and humidity ranges: • Storage Environment • Operation Environment Temperature: Temperature: -4°F~158°F 50°F~104°F (-20°C~70°C) (10°C ~40°C) Humidity: Humidity: Less than 90% RH Less than 90% RH 29 30 PoTENTIAL foR ELECTRoMAGNETIC INTERfERENCE To avoid inaccurate results caused by electromagnetic interference between electrical and electronic equipment, do not use the device near a cell phone or microwave oven. 31 TRouBLESHooTING If any abnormality arises during use, please check the following points: SYMPTOMS POSSIBLE CAUSES CORRECTION Unit does not Batteries have run Replace them turn on when the down. with two new AAA START/STOP alkaline batteries. button is pushed. Battery polarities have been positioned incorrectly. Re-insert the batteries in the correct positions. EE measurement Cuff has been placed Wrap the cuff error symbol shown incorrectly. proerly so that it is on display or the positioned correctly. blood pressure value is displayed excessively low (or high). Did you talk or move during measurement? Measure again. keep wrist steady during measurement.Shaking of the wrist with the cuff on. E1 error symbol Air circuit Measure again. shown on display abnormality. E2 error symbol Inflation pressure Switch the unit off, shown on display exceeding 300 mmHg. then measure again. E3 error symbol Error determining Measure again. shown on display measurement data. Note: If the unit still does not work, contact HoMedics Consumer Relations. Under no circumstance should you d...

Other models in this manual:
Heart Rate Monitors - BPW-060 (2.87 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category