Login:
Votes - 3, Average rating: 4 ( )

User manual Oregon, model BPW813

Manafacture: Oregon
File size: 818.12 kb
File name: fd9243f5-eb13-48d0-b18f-2a803914e80d.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


2 Front View ....................................................... 2 Rear View ........................................................ 3 LCD Symbols .................................................. 3 Safety and Care Instructions ............................. 4 Safety Precautions .......................................... 4 Caring for Your Blood Pressure Monitor .......... 5 About Blood Pressure ........................................ 5 How the Blood Pressure Monitor Works .......... 7 Getting Started .................................................... 7 Installing and Replacing the Batteries ............. 7 Setting Date, Time and Measurement Units ... 8 Positioning the Wrist Cuff ................................ 8 Voice Playback of Blood Pressure Measurements ... 9 Volume Control ................................................ 9 Taking a Blood Pressure Measurement ............ 9 Recalling Measurements Stored in Memory .. 11 Deleting a Measurement Record from Memory .. 12 Deleting the Latest Record ........................... 12 Deleting All Records ..................................... 13 Troubleshooting ............................................... 13 Technical Specifications .................................. 15 About Oregon Scientific ................................... 16 Information About the CE Mark ....................... 17 Blood Pressure Log Book ................................ 17 1 ........................D 2 10/20/04, 5:13 PM INTRODUCTION KEY FEATURES EN Thank you for selecting the Oregon ScientificTM FRONT VIEW Talking Wrist Type Blood Pressure Monitor (BPW813). The BPW813 features voice announcement and playback of blood pressure measurements for added convenience and has been designed to provide you with many years of reliable service. The unit can help you measure and track the following metrics: • Systolic pressure • Diastolic pressure • Mean arterial pressure • Pulse rate • Historic record of up to 60 measurements per user (maximum 2 users) Readings taken by the BPW813 are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method, within the limits prescribed by "EN1060-3 Non-invasive Sphygmomanometers-Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems." The monitor's accuracy in measuring diastolic pressure was tested using the fifth Korotkoff sound method. 2. LCD 3. This manual contains important safety and care 4. Speaker information, and provides step-by-step instructions for using the product. 5. 6. Read the manual thoroughly before using the product. 7. SET button 2 12354671. TALK / VOLUME button ON / OFF button USER 1 / UP ARROW button USER 2 / DOWN ARROW button ........................D 3 10/20/04, 5:13 PM LCD SYMBOLS EN 21REAR VIEW 1. Wrist cuff SYMBOL DESCRIPTION EXPLANATION Systolic pressure The highest blood pressure measured Diastolic pressure The lowest blood pressure measured Time (hour: minutes) Current time Mean arterial pressure Average blood pressure measured (see "What is Mean Arterial Pressure (MAP)?" for more information) Pulse Pulse rate per minute User Shows which user profile (1 or 2 is being displayed) Memory If "MEM" shows, the displayed measurement value is from the memory and not necessarily from the last reading 2. Battery compartment 3 ........................D 4 10/20/04, 5:13 PM SAFETY AND CARE INSTRUCTIONS EN SYMBOL DESCRIPTION EXPLANATION Weak battery Batteries are low and need to be replaced Inflating Unit is inflating with air to obtain the needed level of pressure Deflating Wrist cuff air is exhausting or deflating Millimeter(s) of mercury Measurement unit for blood pressure kPa Kilopascal Measurement unit for blood pressure Voice activation Voice announcing your blood pressure measured SAFETY PRECAUTIONS Please observe the following safety precautions when setting up and using your blood pressure monitor. • This device is intended for adult use only. • This device is intended for non-invasive measuring and monitoring of arterial blood pressure. It is not intended for use on extremities other than the wrist or for functions other than obtaining a blood pressure measurement. • Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood pressure. Do not begin or end medical treatment based solely on the measurements of this device. Consult a physician for treatment advice. • If you are taking medication, consult your physician to determine the most appropriate time to measure your blood pressure. Never change a prescribed medication without consulting your physician. • This unit is not suitable for continuous monitoring during medical emergencies or operations. • If the cuff pressure exceeds 40 kPa (300 mmHg), the unit will automatically deflate. Should the cuff not deflate when pressures exceeds 40 kPa (300mmHg), detach the cuff from the wrist and press the button to stop inflation. •To avoid measurement errors, carefully read...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category