Manafacture: Aprilaire
File size: 1.1 mb
File name: 8600.pdf
|
manual abstract
Only use your fingertips. THERMOSTAT fEATURES • Large touch screen with adjustable backlight – constant backlight available. • Message center provides feedback and instructions. • 7 day programmability or separately programmable weekday/weekend schedules. • Thermostat can be removed from the wall for easy programming (batteries must be installed). • Front battery door access for fast, easy replacement. • Displays room temperature, temperature setting, and optional outdoor temperature. • Air filter, humidifier, dehumidifier, and HVAC service indicators. • Programmable fan control with fan circulation mode. • Easy to use temperature control can override program schedule at any time. • Progressive recovery ensures proper temperature at the start of a program event. • Built in compressor protection prevents damage to your equipment. 61000728A 8600 Tstat Owners.indd 3 10/7/10 11:44:50 AM AbOUT yOUR NEw THERMOSTAT AbOUT yOUR NEw THERMOSTAT CONTROlS & DISplAy OVERVIEw – HOME SCREEN ROOM TEMPERATURE TEMPERATURE SETTING FAn MoDE BUTTON TEMPERATURE ADJusTMEnT FAn MoDE SETTING sysTEM MoDE BUTTON HoLD BuTTon (sETs or CLEArs HoLD) sysTEM MoDE SETTING HEAT pUMp MODE ONly EMErgEnCy HEAT (rED) EQUIPMENT STATUS sysTEM FAuLT (yELLow) inDiCATor sHows THrougH Housing MESSAGE CENTER (SCROLLING TEXT) Low BATTEry inDiCATor CurrEnT TiME & DATE MAIN MENU BUTTON CurrEnT DAy ouTDoor TEMPErATurE NOTE: BACkLigHT is ACTiVATED wiTH FirsT BuTTon PrEss AnD AuToMATiCALLy Turns oFF. 61000728A 8600 Tstat Owners.indd 4 10/7/10 11:44:52 AM AbOUT yOUR NEw THERMOSTAT AbOUT yOUR NEw THERMOSTAT CONTROlS & DISplAy OVERVIEw – MAIN MENU CLEAN SCREEN (LOCKOUT TOUCH SCREEN For 30 sEConDs) sET VACATion HoLD (HoLD–To TiME AnD DATE) SET CURRENT TIME sET sCHEDuLE BUTTON sET CurrEnT DATE DonE BuTTon (EXIT MENU) usEr sysTEM sETTings 61000728A 8600 Tstat Owners.indd 5 10/7/10 11:44:53 AM OpERATION OpERATION SElECT SySTEM MODE CHANGE TEMpERATURE SET pOINT (EM HEAT/HEAT/OFF/COOL/AUTO) press [MODE] to select: EM HEAT: (only for heat pumps with auxiliary heat) Thermostat controls auxiliary heat Heat pump will not operate in EM HEAT mode . HEAT: Thermostat controls only the heating system . Off: Heating and cooling systems are off . COOl: Thermostat controls only the cooling system . AUTO: (if enabled in installer setup) Thermostat automatically selects heating or cooling depending on the indoor temperature . press [DONE] to save and exit, or [CANCEl] to exit without saving The thermostat will save and exit if nothing is pressed within 10 seconds . press or to adjust the current set point. (See Program Schedule Holds on pages 14-16 for more information ) 61000728A 8600 Tstat Owners.indd 6 10/7/10 11:44:54 AM OpERATION OpERATION SElECT fAN SETTING (ON/AUTO/CIRC) When the fan mode is changed during a program event it remains in that mode until the next event starts The fan must be programmed to FAn on in the schedule to run continuously through all events press [fAN] to select: ON: Fan runs continuously. use this mode for maximum air circulation/filtering AUTO: Fan runs only when the heating or cooling system is on CIRC: same as AuTo, but ensures the fan is on for at least 20 minutes per hour Use this mode for a balance of energy savings and air circulation/cleaning press [DONE] to save and exit, or [CANCEl] to exit without saving The thermostat will save and exit if nothing is pressed within 10 seconds ClEAN SCREEN press [MENU] to enter the main menu press [ClEAN SCREEN] to disable the touch screen for 30 seconds for cleaning Note: Use a soft damp cloth to clean the screen Use water or household glass cleaner. Do not spray liquids directly on the screen MAINTENANCE REMINDERS Maintenance reminders are set up by the installer to indicate when the equipment is due for service. if a maintenance reminder is displayed, call your HVAC dealer for service They can be cleared by pressing [MENU] to enter the main menu, then [Next] to clear each reminder SCREEN lOCKOUT The user can disable certain features of the thermostat (See User System Setting Table on page 18 for details ) This feature can be overridden by pressing and holding [MENU] for 7 seconds 61000728A 8600 Tstat Owners.indd 7 10/7/10 11:44:55 AM OpERATION OpERATION bATTERy INSTAllATION The thermostat can either be AC or battery powered, or both If the thermostat was wired to be AC powered when installed, batteries are optional (to provide backup power for clock) The thermostat has a memory backup that saves the thermostat’s settings in case of a power interruption The system settings will be retained but the clock will reset after 90 seconds with no battery or AC power The reset button located under the battery cover can be used to reset the thermostat to factory defaults RESETBUTTON wARNING The reset button should only be used by the installer. 61000728A 8600 Tstat Owners.indd 8 10/7/10 11:44:55 AM pROGRAMMING pROGRAMMING SET TIME SET DATE press [MENU] to enter the main menu press [MENU] to enter the main menu . pr...