Login:
Votes - 2, Average rating: 4 ( )

User manual Honeywell, model 42711-01

Manafacture: Honeywell
File size: 1.43 mb
File name: 42711.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Set & $aveSet & $aveSet & $ave installation and operation manual Model 44260 Programmable Thermostat English 2 Table of Contents Important Information ....................................... 5 Tools 6 Uninstalling the Existing Unit............................7 Installing the Thermostat ................................ 12 installing the wall plate ................................ 12 connecting the wires ................................... 16 attaching the thermostat ............................. 18 Settings........................................................... 22 Methods of Operation.....................................26 manual operation ........................................ 28 default programs ......................................... 32 creating custom programs .......................... 34 Icons and Features......................................... 38 Wiring ............................................................. 49 Troubleshooting.............................................. 52 Set & Save Set & SaveSet & Save Programmable ProgrammableProgrammable Thermostat ThermostatThermostat Model 44260 Model 44260Model 44260 Congratulations! Thank you for choosing a Hunter programmable thermostat. Your new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete operation instructions. iMporTanT inforMaTion This thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – Fired Boilers Gas – Milivolt Systems Oil – Fired Boilers Oil – Fired Furnace Electric Furnace Electric Air Conditioning Single Stage Heat Pump - No auxilary This thermostat is not designed for multi-stage heatpump systems or 110/220 V baseboard heating systems. If you are unsure what kind of heating and cooling system you have, please contact a qualified HVAC Technician for assistance. ToolS This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your new thermostat, you will need the following supplies: Flat-head screwdriver .................................................................................... Small Phillips-head screwdriver .................................................................................... Hammer .................................................................................... Electric drill and 3/16” bit .................................................................................... Two 1.5 Volt (AA) size alkaline batteries .................................................................................... noTiCE! Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection. 8 YRCGWYRCGW YRCGWYRCGW uninSTalling ThE ExiSTing uniT 1. Turn the system power OFF from the existing thermostat. Turn the power to the HVAC system OFF at the main power panel or at the furnace. 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that must be removed or disengaged.) 3. Locate, but do not disconnect the wires. (If wires are not visible, they may be connected to the back of the wall plate. Some models may have doors that open to expose the wires and mounting screws.) if your existing thermostat is label the wire with this marked... sticker: RH / R / VR / 4 24 Volt RH RH RC / VC 24 Volt cool RC RC G / F W / H / B Y1 air conditioning compressor Y / C* / M / O Y/0 Y/0 heating fan heat pump compressor G G W/B W/B Y1 Y1 uninSTalling ThE ExiSTing uniT, ConT. 4. Using the provided stickers, label each wire according to the chart. (If the terminals are not labeled, contact a qualified HVAC technician.) note: Wire colors do not always comply with standards, so wire color should be ignored. refer to the existing terminal designation for proper identification. *If wires marked Y & C are both present, C may be a Common wire and should not be used. If you have a wire marked C, do not connect itto any terminal. This wire is used only for non- battery powered thermostats. 5. Do not let the wires slip back into the wall during disconnection. You may want to secure the wires to the wall as you disconnect them. After all wires are labeled, disconnect each wire and remove the existing wall plate. 12 WRCYG WRCYG inSTalling ThE ThErMoSTaT inSTalling ThE Wall plaTE 1. Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing holes, visually level the wall plate and mark the wall for two holes. 14 WRCYG WRCYG inSTalling ThE ThErMoSTaT, ConT. 4. Remove the wall plate and dr...

Other models in this manual:
Thermostat - 42711-01 (1.43 mb)
Thermostat - 42711-01 (1.43 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category