3 4 5 Display 1 Mode Indicators Selects the operation mode of the equipment. COOL — indicates the air conditioning mode. HEAT — indicates the heat mode. AUTO — indicates the system will automatically changeover between the heat and cool modes as the temperature varies. OFF — indicates the entire system is turned off. PROGRAM ON —indicates the stored program is enabled to run. See below. 2 Clock with Day of the Week Indicates the current time and day. This clock is also used to program the timer periods. See below. Room Temperature Display Indicates the current room temperature. Desired Set Temperature Indicates desired room temperature(s). See page 3. Override Indication Indicates the current program is currently being overridden for up to 4 hours. See pages 3 and 5. 6 Occupied or Unoccupied Indication Indicates the program number: Occupied 1, 2, 3, or Unoccupied. See pages 3 and 4. 7 Setup Indication Indicates the thermostat is in the programming mode. See page 4. 8 Fan Operation Indication Fan On Icon — indicates constant continuous fan operation. When FanOnIcon is not lit — indicates the fan will only operate when necessary to heat or to cool. 9 Locked Indication Locked appears after the right combination of buttons are pressed, rendering the buttons inoperative. See page 5. 10 Start/Stop Indication Start or Stop appears when programming timer functions. See page 3. Quick Start Set the Clock and Go OFFON AU T O SetupProgram On Stop Start Am Pm SuMT uWThFSa : Override Locked unoccupied 123 2 5 16 9 7 4 1 1 3 8 10 1 4 COOL HEAT Fan Pm M : NOTE: During Setup and Programming: Pressing the Mode button selects different flashing items (represented in black). Pressing the Up and Down buttons will modify the flashing selection. The thermostat is preprogrammed from the factory to operate equipment* without the need for further programming. To optimize the installation of this thermostat follow the instructions in the Advanced Setup section. *Thethermostatisnotpreprogrammedfromthefactorytooperateheat pump systems. To control these systems, follow the steps in the AdvancedSetupsection,page4. Basic Operation Select Mode The HEATsettingindicates thetemperaturetheroomhas toreachbeforetheunitwill turnontoheattheroom. The COOLsettingindicates thetemperaturetheroomhas toreachbeforetheunitwill turnontocooltheroom. AUTOwillautomatically selectheatorcoolbasedon roomtemperaturedemand. ProgramOnwillactivatethe storedtimeroperation. (OccupiedandUnoccupied periods.) OFFindicatesthesystemis turnedoff. M : Pm HEAT M : Pm COOL M AU T O : Pm HEAT COOL M : unoccupied Program On Pm OFF M : Pm Page 2 Basic Operation SelectDesiredTemperature In any mode, adjust the desired Set Point Temperature with Basic Operation SelectDesiredTemperature In any mode, adjust the desired Set Point Temperature with AUTO M : Pm HEAT COOL buttons. Pressing the up/down buttons in Auto mode will adjust both the heat and cool set point temperatures simultaneously. Pressing the up/down buttons in Heat or Cool modes will adjust only the heat or cool set point temperature. COOL During programmed, unoccupied Override periods a press of the Override button will force the thermostat into Occupied 1 comfort settings, : : temporarily. ProgramOn Stop Su Pm unoccupied With each successive push of the Override button, the override timer will add 30 minutes, until the maxi- HEAT mum of 4 hours is reached. Then the next press will zero out the override timer, returning to unoccupied if there are no further button presses. When in Override, the Override icon and the Occupied 1 icon appear on : Pm the display. The time of day clock alternates with : : ProgramOn the time remaining in override. occupied 1 COOL During Override, the set point tem- Override peratures are adjustable, provided HEAT the keypad is not locked. Su Programming Occupied and Unoccupied Periods occupied 1 Select the maximum number of occupied periods to be used on any one day. Typically 1. (1,2 or 3) occupied 1 COOL Adjust the cooling set point for occupied 1. (35 to 99 F) occupied 1 COOL HEAT Adjust the heating set point for occupied 1. (35 to 99 F) unoccupied COOL Adjust the cooling set point for unoccupied periods. (35 to 99 F) unoccupied COOL HEAT Adjust the heating set point for unoccupied periods. (35to99F) occupied 1 M Select the day for Occupied 1. : : Am Start occupied 1 Adjust the start time M for occupied 1. : Pm Stop occupied 1 Adjust the stop time M for occupied 1. occupied 1 M ON Select Occupied 1 to run on this day (On), or not to run this day (Off). The copy command becomes available after the maximum number of occupied periods are programmed in a day. This example uses 1 as the maximum occupied periods ever programmed in one day. occupied 1 StartAm occupied 1 Tu Selecting Yes, then pressing mode will copy the previous day’s program and then will ask the same copy question again. If yes is selected each time, this routine will repeat until Saturday is copied to Sunday. After Saturday is c...