|
manual abstract
If you prefer to use normal recovery, slide the switch to the DISABLE position. Auto Recovery (SW4) System Selector (SW5) Fan Option (SW6) Figure 7 STD HP DISABLE ENABLE HG HE F° / C° Selection (Fahrenheit / Celcius) Your thermostat is set for F° mode from the factory. To change to C° mode, follow these steps: ¦ Press and hold the Up key. ¦ Use a paper clip to press the reset key. ¦ Once all the LCD segments turn on, release the Up key. NOTE: To return to F° mode, press the reset key with a paper clip. Do not press any other keys during the reset process. All programs and settings will be lost when pressing RESET. OPERATION Setting Day and Time ¦ The LCD will show this information when batteries are first installed, or after the Reset button is pressed. The temperature will update after a few seconds. ¦ During time and day setting mode, the temperature and program displays will go blank. ¦ Example: Set the Thermostat to the current time of 2:16 pm on Saturday. Refer to the Steps below. M AM 4 TEMP STEP 1: day/time ¦ Press to enter time and day setting mode. The current hour and the AM / PM indicator will be flashing. ¦ Press to change the Hour up or down to the current hour. Note the AM / PM indicator, as the display will change at 12 AM and 12 PM. M AM (Continued) Setting Day and Time (Continued) STEP 2: day/time ¦ Press again to change from hour setting to minute setting. The current minute will be flashing. ¦ Press to change the Minute up or down to the current minute. M PM STEP 3: day/time M PM ¦ Press again to change from minute setting to day setting. The current day will be flashing. ¦ Press to change the Day up or down to the current day. STEP 4: day/time ¦ Press again to change back to the SA normal display. or PM hold 2 /return TEMP NOTE: You may press hold at any time during Day and Time setting to return to /return the normal display. 12 Hr. / 24 Hr. Time Format Your thermostat is set from the factory in normal 12 (AM / PM) time format. To change to 24 hour (military) time, press program at any time while the Hour, Minute, or Day is flashing to toggle between the 12 hour and 24 hour formats. The AM / PM indicator will not be displayed in 24 hour mode. Both the current time and all programs will automatically change to the selected format. PROGRAMMING The following time and temperature settings are pre-programmed into the thermostat: Temperature in C° (F°) Program Number Time Heat Cool 1 6:00 am 68°F (20°C) 78°F (26°C) 2 8:00 am 60°F (16°C) 85°F (29°C) 3 4:00 pm 68°F (20°C) 78°F (26°C) 4 10:00 pm 60°F (16°C) 82°F (28°C) ¦ All 7 days of the week have the same default programs. Personal Program Schedule ¦ You can revise the factory programs to match your own schedule. Use this Personal Program Schedule to determine which times and temperature settings match your comfort and energy saving requirements. Use a pencil so you can revise your records each time you change your program settings. Heating Day Program 1 Program 2 Program 3 Program 4 Monday – Friday Time Temp Time Temp Time Temp Time Temp Saturday Time Temp Time Temp Time Temp Time Temp Sunday Time Temp Time Temp Time Temp Time Temp Cooling Day Program 1 Program 2 Program 3 Program 4 Monday – Friday Time Temp Time Temp Time Temp Time Temp Saturday Time Temp Time Temp Time Temp Time Temp Sunday Time Temp Time Temp Time Temp Time Temp Revising Programs ¦ Familiarize yourself with manually changing programs, so that you can easily modify the programs as your comfort needs change. Follow the steps below to change the program times and temperatures. NOTE: 1) The program time can be set in 10-minute increments. 2) The program temperature can be set in increments of 1°F (1°C). 3) After 15 seconds without a key press, the thermostat will return to normal display mode. 4) When setting the program time, note the AM / PM indicator. STEP 1: system ¦ Slide the System Switch to the HEAT or heat COOL position to program the correspond- off cool ing system. NOTE: If the System Switch is in the OFF position, the last position used will be programmed. SA PM TEMP 2 STEP 2: program ¦ Press to enter program mode. HEAT or COOL will be displayed on the LCD. 1 MT WTHF AM STEP 3: ¦ The Program hour and AM or PM indicator are flashing. Press to change the hour. ¦ Press again to change to the minute position. The current minute will be flashing. ¦ Press to change the minute. HEAT STEP 4: program FTHWT AM HEAT M 1 STEP 5: program STEP 6: ¦ Press again to change to the program tem- perature. The current temperature will be flashing. ¦ Press to change the temperature. M FTHWT AM HEAT program ¦ Press again to move to the next program number. ¦ Repeat Steps 3 through 5 to change the remaining Weekday, Saturday, and Sunday programs. (There are a total of 12 programs.) program hold ¦ After cycling through all 12 programs, press again to return the display to normal. ¦ Press at any time to exit the Program Mode. /return 1 Reviewing Programs To review your program settings, pres...
Other models in this manual:Thermostat - 43255 (292.59 kb)
Thermostat - 43255 (292.59 kb)