Once set, press on RET button to exit the time and day adjustment mode Note 1 : Time indicator is showing you that the time must be set. Note 2 : The thermostat has an automatic return. When such functions as time recording, programs recording, etc., are not completed by pressing on RET button, the thermostat will automatically exit the mode after 60 seconds. 2) Typical suggested programs This thermostat can store up to four (4) daily programs for weekdays and four (4) daily programs for the weekend. Also, there is two (2) programs for the ECONO mode. To practice programming use the following example. Program number Time Temperature setting Weekday programs (Mon...Friday) Program 1 6:30 AM 20 °C Program 2 8:30 AM 15 °C Program 3 4:30 PM 20 °C Program 4 11:00 PM 15 °C Weekend programs (Sat & Sun) Program 1 7:00 AM 20 °C Program 2 8:30 AM 15 °C Program 3 4:30 PM 20 °C Program 4 11:00 PM 15 °C ECONO mode programs (weekend cottage) Program 1 Friday 3:00 PM 20 °C Program 2 Friday 8:00 PM 15 °C 400-102-000-A 2/4 3) Recording the heating programs Select the AUTO mode. Press on PGM button once. The default values or the last recording of program 1 will be displayed. The default values are : • 20 °C and the time -- -- : -- -The days Monday to Friday are displayed to show that this program is for weekdays. Press on HOUR and MIN buttons until 6:30 AM is displayed. Press on or until 20 °C is displayed. The first program is recorded. Press on PGM button again to record or modify weekday programs 2, 3 and 4 and weekend programs 1, 2, 3 and 4. Use HOUR, MIN, or buttons to modify the time and setpoint of programs. Programming is now completed. Press on RET button or wait for the "automatic return" to exit the programming mode. Note: A program time left at -- -- : -- -- is considered inactive. To reset a program, use PGM button to select the program, then press on MODE button. To review programs, press on PGM button successively to see the programs one after the other and make modification if required. 4) Recording the ECONO programs Select the ECONO mode. Press on PGM button once. The default values or the last recording of program 1 will be displayed. The default values are : • 10 °C and the time ---- : -- -- Use DAY, HOUR, MIN and or buttons to record the day, the time and the setpoint of program 1. Press a second time on PGM key. The default values or the last recording of program 2 will be displayed. Use DAY, HOUR, MIN and or buttons to modify the day, time and setpoint of program 2. Programming is now completed. Press on RET button or wait for the "automatic return" to exit the programming mode. CHARACTERISTICS 1) Proportional and on/off controls This thermostat works differently than the conventional electro-mechanic one. The latter can have a differential of temperature up to 4 °C while this electronic thermostat has one of only 0.3 °C. This slight oscillation eliminates the discomfort often found with conventional electro-mechanic thermostats. The proportional controller determines the amount of power required by the electric heating system to maintain the exact ambient temperature of the temperature setting. To see this process, the display shows, in real time, the percentage of power applied to the electric heating system. If you have programmed the heating control to ON/OFF to control a fan equipped system, the display will show the fan indicator and 100% when the heating system will turn ON and 0% when it will turn OFF. In this case, the temperature regulation will be ±0.5 °C around the setpoint. 2) Characteristics • Models: TH102 and TH102-3 • Electronic programmable line voltage thermostat (2 wires non polarized) • Supply: 120/240 VAC, 50/60 Hertz • Load: 10.4 A maximum, 1.0 A minimum (Resistive only) • Power: 2500 W @ 240 VAC or 1250 W @ 120 VAC (TH102) 3000 W @ 240 VAC or 1500 W @ 120 VAC (TH102-3) • Power consumption (off): 860 mW • Approvals: CSA / UL • Display range: 0 to 99 °C (0 to 99 °F) • Setting range: 5 to 27 °C (40 to 80 °F) • Storage: -20 to 50 °C (-4 to 120 °F) • Temperature regulation: 0.3 °C (proportional), +/- 0.5 °C (ON/OFF) • Precision: ± 0.5 °C • 10 programs: 4 weekday programs, 4 weekend programs and 2 ECONO programs NOTE : In normal use at full capacity (2500 W), the housing temperature of the thermostat can reach 35 to 40 °C. 400-102-000-A 3/4 WARRANTY AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original purchase from authorized dealers. During this period, AUBE technologies inc. will repair or replace the product with a new or of equivalent quality at AUBE'S option, without charge, any product proven defective in normal use. Warranty does not cover transportation costs. Nor does it cover a product subjected to misuse or accidental damage. This warranty does not cover the cost of installation, removal or reinstallation. This limited warranty is in lieu...
Other models in this manual:Thermostat - TH102-3 (185.78 kb)