Login:
Votes - 4, Average rating: 4.5 ( )

User manual Panasonic, model TH-37PR10UA

Manafacture: Panasonic
File size: 4.2 mb
File name: TH37PR10UA.PDF
Language of manual:enetsl
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


On: Enable ID remote control functions. Serial ID Off On Sets the panel ID Control. Off: Disables external control by the ID. On: Enables the external control by the ID. Adjusts the image display size on screen. Off: Sets the normal image display size on screen. On: Sets the image display size approximately 95 % of the normal image display. Off On Display size Off On Notes: • This setting is valid only when the input signals are as follows; NTSC, PAL, SECAM, M.NTSC, PAL60, PAL-M, PAL-N (BNC Dual Video Terminal Board (TY-FB9BD)) 525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI) • This setting is invalid when two screen display, digital zoom or Multi screen is selected. • When “Display size” is set to “On”, “POS. /SIZE” adjustment cannot be used. • Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals. Studio W/B Off On Off: Nullify all the settings adjusted. On: Sets the color temperature for TV studio. Note: Valid only when the low is set as color temperature on screen adjustment. Studio Gain Off On Sharpens the contrast for a better view when a part of the image is too light to see. Off: Disables “Studio Gain”. On: Enables “Studio Gain”. Note: This setting is valid only when the input signals are as follows: Component Video, RGB (analog), SDI, HDMI Options Adjustments 3/3Options Off Off Off V. lnstallation Rotate Slot1Serial Slot Select Slot power Item Effect Adjustments Slot Power Off Auto On Off: Power is not transmitted to the slot power. Auto: Power is transmitted to the slot power only when main power is on. On: Power is transmitted to the slot power when main power is on or in the standby state. Note: In some cases, power is transmitted to the slot power when main power is on or in the standby state regardless of the slot power setting. V.Installation Off On Note: This mode is unavailable. Rotate Off On Off: Does not rotate the image. On: Rotates the image 180 degrees. Serial Slot Select Slot1 Slot2 Slot3 Selects the slot which communicates serial. Note: The setting of an external command can be set only from the fixed serial terminal (see page 11). Normalization When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID” adjustments, set all the values “Off” so that all the buttons are enabled again. Press the button on main unit together with button on the remote control and hold for more than 5 seconds. The VOL “SHIPPING” menu is displayed and the lock is released when it disappears. Options Adjustments Weekly Command Timer You can set 7-day timer programming by setting time and command. Note: Before setting Weekly Command Timer, set PRESENT TIME SETUP. (see page 26) Press to select Function. 1 Press to select “On”. Options On Weekly Command Timer Onscreen display 1/3 Note: Press ACTION ( ) button • When Function is set to On, SET UP TIMER (see page 27) is unavailable and INTERVAL / TIME OF DAY in MODE of SCREENSAVER (see page 28) cannot be selected. Press to select a day. Press to select a program number. Note: • You can set the program from 1 to 7. --- indicates unset. 3 Press to select Program Edit. Press to show the Program Edit screen. Press to select Program. 4 Press to change the program numbers (1-7). Weekly Command Timer On Program1 Function Monday Program3Tuesday ---Wednesday Program3Thursday ---Friday Program6Saturday Program4Sunday Program Edit Weekly Command Timer Program1 On Monday Function Program3Tuesday ---Wednesday Program3Thursday ---Friday Program6Saturday Program4Sunday Program Edit Program3Thursday ---Friday Program6Saturday Program4Sunday Program Edit Program number Program Edit screen Weekly Command Timer 8:00 10:30 01 02 1/8 --:--03 --:--04 --:-- --:-- 05 12:0006 9:12 PON IMS:SL1 --- --- --- --- DAM:ZOOM AVL:10 07 08 1Program Options Adjustments 5 Press to select a command number. Press to show the previous / next command pages (1-8) of the selected program. Press to show the command setting screen. Command (--- indicates unset) Set time of timer (--:-- indicates unset) Command numbers Weekly Command Timer 8:00 10:3002 01 1/8 --:--03 --:--04 --:-- --:-- 05 12:0006 9:12 PON IMS:SL1 --- --- --- --- DAM:ZOOM AVL:10 07 08 1Program Weekly Command Timer 20:00 20:30 57 58 8/8 22:0059 --:--60 --:-- --:-- 61 --:--62 --:-- AVL:00 DAM:NORM POF --- --- --- --- ---63 64 1Program Press to select Command No. Command setting screen 6 Press to select a command number. Weekly Command Timer 02Command No 10:30Time IMS:SL1Command 1Program Press to select Time / Command. 7 Press to set each item. Time: Set the time to execute a command program. Pressing “ ” or “ ” button once changes “Time” 1 minute. Pressing “ Weekly Command Timer Command 02Command No IMS:SL1 10:30Time 1Program ” or “ ” button continuously changes “Time” by 15 minutes. Command: Select a command to execute at the set time. This unit ha...

Other models in this manual:
Televisions - TH-42PR10UA (4.2 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category