Login:
Votes - 4, Average rating: 4.3 ( )

User manual Nilfisk-ALTO, model R 571

Manafacture: Nilfisk-ALTO
File size: 1.5 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Sit on the driver seat. NOTE: The machine will not traverse if the operator is not properly seated. 2. Turn the key switch to the “ON” position. 3. Raise the brush to the highest position (if necessary). 4. Raise the squeegee (if necessary). 5. Gently press the foot pedal and the machine will begin to move. 6. To stop, release pressure on the foot pedal. 7. To travel in reverse, select reverse with the forward/ reverse switch. 8. To stop, release pressure on the foot pedal. 9. When you stop the machine, turn the key switch “OFF” and remove the key. Do These Procedures When You Begin Your Work Period 1. Make sure the key switch is in the “OFF” position. 2. Disconnect AC power from battery charger (follow charger instructions). 3. Make sure the filter screen (1) to the vacuum motor is clean and installed properly in the recovery tank (see figure 30). 4. Make sure the recovery tank lid is in place and has been tightened (see figure 31). 5. Close and secure the lower cleaning port cover (if so equipped) on the recovery tank. 6. Make sure that the plug in the recovery drain hose is in place and has been tightened (see figure 32). 7. Make sure that the brushes/pads are in position and installed correctly. 8. Make sure the brush housings are in position on the brush head. 9. Check the installation of the squeegee and squeegee hose. Figure 30 Figure 31 Figure 32 Page -20- CLARKE TECHNOLOGY Operator's Manual -SCRUBTEC R Manual Steering SCRUBTEC R Manual SteeringSCRUBTEC R Manual SteeringSCRUBTEC R Manual SteeringSCRUBTEC R Manual SteeringSCRUBTEC R Manual Steering How To Operate the Machine How To Operate the Machine WARNING: Water solutions or cleaning materialsused with this type of machine can leavewet areas on the floor surface. These areas can cause a dangerous conditionfor the operator or other persons. Always put CAUTION signs near the areayou are cleaning. For one touch automatic cleaning follow this procedure: 1. Turn the key switch to the “OFF” position. 2. Put the water and a cleaning chemical in the solution tank. 3. Sit on the driver seat. NOTE: The machine will not traverse if the operator is not properly seated. 4. Turn the key switch “ON”. NOTE: The key switch turns onthe battery and LED screen displays, which shows themachines condition. 5. The machine has a one touch button on the control panel(see figure 33) that is preset for brush pressure andsolution flow. Momentarily depress the one touch button ifyou wish to use these settings. NOTE: If this is not the settings that you desire see page 16 or one touchoperation. For manual control of cleaning process, follow these procedures: 1. Turn the key switch to the “OFF” position. 2. Put the water and a cleaning chemical in the solution tank. 3. Sit on the driver seat. NOTE: The machine will not traverse if the operator is not properly seated. 4. Turn the key switch “ON”. NOTE: The key switch turns onthe battery and LED screen displays, which shows themachines condition. 5. Lower the squeegee. NOTE: The vacuum motor will turn on when the squeegee up/down switch is placed in thelower position. 6. Lower the brush head until it reaches the full stroke down. NOTE: The brushes will start rotating only when the machine begins to traverse. 7. Reset the solution flow valve by using the + / - solutionswitch. NOTE: The solution will flow only if the machineis moving forward. 8. After a few feet of scrubbing, check to see that the amountof solution being applied is correct and that the squeegeeis picking up water and drying the floor. Make adjustmentsas required. 9. Once the machine is set properly continue to scrub until thesolution low indicator comes on or until you run out ofsolution. NOTE: When making multiple passes across the floor, overlapthe brush cleaning path approximately 2 inches (5 cm) of thearea already cleaned by the brush. NOTE: During most cleaning procedures, apply and remove thesolution in one operation. Figure 33 CLARKE TECHNOLOGY Operator's Manual -SCRUBTEC R Manual Steering SCRUBTEC R Manual SteeringSCRUBTEC R Manual SteeringSCRUBTEC R Manual SteeringSCRUBTEC R Manual SteeringSCRUBTEC R Manual Steering Page -21 How To Operate the Machine How To Operate the Machine To clean a very dirty floor, follow this procedure: 1. Apply solution to the floor. 2. Do not lower the squeegee. This will keep the vacuum motor off. 3. Lower the brush or pad and scrub the floor. 4. Scrub the floor again with additional solution and lower the squeegee. 5. Pick up all the solution with the squeegee. Do These Procedures When You End Your Work Period Having finished the job and before any type of maintenance is done, follow these procedures: For one touch cleaning shut down process, press and release the one touch button. For manual shut down follow these procedures: 1. Turn the solution flow off by decreasing the flow to its minimum position. 2. Press the brush up/down switch to the up position until the brush head has reached its up most position. 3. Place the squ...

Other models in this manual:
Dryers - 571 (1.5 mb)
Dryers - 571 C (1.5 mb)
Dryers - 586 (1.5 mb)
Dryers - BOOST R (1.5 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category