Login:
Votes - 1, Average rating: 5 ( )

User manual Frigidaire, model 137112200B

Manafacture: Frigidaire
File size: 3.43 mb
File name: 137112200es.pdf
Language of manual:enes
Free link for this manual available at the bottom of the page



manual abstract


Refer to the pre-installation requirements in this manual for the proper power cord to be purchased. WARNING ELECTRICAL SHOCK HAZARD A U.L.-approved strain relief must be installed onto • power cord. If the strain relief is not attached, the cord can be pulled out of the dryer and can be cut by any movement of the cord, resulting in electrical shock. Do not use an aluminum wired receptacle with a• copper wired power cord and plug (or vice versa). A chemical reaction occurs between copper and aluminum and can cause electrical shorts. The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle. ..NOTE Dryers operating on 208 volt power supply will have longer drying times than dryers operating on 240 volt power supply. Grounding requirements - Electric dryer (USA) WARNING ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded. For a grounded, cord-connected dryer: 1 The dryer MUST be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current. 2 After you purchase and install a 3 wire or 4 wire power supply cord having an equipment-grounding conductor and a grounding plug that matches you wiring system, the plug MUST be plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician. DO NOT modify the plug you’ve installed on this appliance. For a permanently connected dryer: 1 The dryer MUST be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment- grounding terminal or lead on the appliance. INSTALLATION INSTRUCTIONS Grounding requirements - Electric dryer (Canada) For a grounded, cord-connected dryer: 1 The dryer MUST be grounded. In the event of a malfunction or breakdown, grounding will reduce WARNING ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded. the risk of electrical shock by a path of least resistance for electrical current. 2 Since your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician. DO NOT modify the plug you’ve installed on this appliance. Grounding requirements - Gas dryer (USA and Canada) 1 The dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. 2 The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician. DO NOT cut or remove ground prong from the plug. Grounding typeGrounding type wawall receptaclll receptacle PoPower cord withwer cord with 3-prong3-prong grgrounded plugounded plug Do not,Do not, underunder anany ciry circumstances,cumstances, cut,cut, remoremoveve, or bor bypass thypass the grgrounding prounding prong.ong. INSTALLATION INSTRUCTIONS Gas connection 1 Remove the shipping cap from gas pipe at the rear of the dryer. IMPORTANT DO NOT connect the dryer to L.P. gas service without converting the gas valve. An L.P. conversion kit must be installed by a qualified gas technician. 2 Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of the dryer. Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm) reducer for the connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections. 3 Open the shutoff valve in the gas supply line to allow gas to flow through the pipe. Wait a few minutes for gas to move through the gas line. Shutoff Valve - Open position to dryer from gas supply 4Check for gas system leaks with a manometer. If a manometer is not available, test all connections by brushing on a soapy water solution. All connections must be wrench-tightened Flare Union Flare Union GAS FLOW Manual Shutoff Valve Closed Open Flexible Connector Inlet Pipe on Back of Dryer elppiN WARNING EXPLOSION HAZARD NEVER test for gas leaks with an open flame. IMPORTANT The supply line must be equipped with an approved manual shutoff valve. This valve should be located in the same room as the dryer and should be in a location that allows ease of opening and closing. Do not block access to the ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category