3. A UL approved strain relief must be installed onto power cord. If the strain relief is not attached, the cord can be pulled out of the pulled out of the dryer and can be cut by any movement of the cord, resulting in electrical shock. 4. Do not use an aluminum wire receptacle with copper wired power cord and plug (or vice versa ). A chemical reaction occurs between copper and aluminum and can cause electrical shorts. The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle. Note: Dryers operating on 208 Volt power supply sill have longer drying times than operation on 240 Volt power supply. Danger: Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded. English 3-Wire Cord Connections (USA only) 1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner. 2. Install a U.L. approved strain relief into the power cord entry hole of the mounting bracket. Finger tighten the nut only at this time. 3. Thread a U.L. Approved 30 Amp. Power cord, NEMA 10-30 Type SRDT, through the strain relief. 4. Attach the power cord neutral (center wire) conductor to the brass colored center terminal on the terminal block. Tighten the screw securely. 5. Attach the remaining two power cord outer conductors to the outer brass colored terminals on the terminal block. Tighten both screws securely. Warning: Do not make a sharp bend or crimp wiring/conductor at connections. 6. Reattach the strain relief mounting bracket to the back of the dryer with two screws. Tighten screws securely. 7. Tighten the screws securing the cord restraint firmly against the power cord. 8. Tighten the strain relief nut securely so that the strain relief does not turn. 9. Reinstall the terminal block cover. Brass Terminal Nut Tighten Nut to These Threads Power Cord Strain Relief Mounting Bracket Green Ground Screw Green Neutral Ground Wire 10 English 4-Wire Cord Connections Brass Terminal Red Tighten Nut to These Threads Power Cord Strain Relief Mounting Bracket Green Ground Screw Green Neutral Ground Wire Terminal Block Black Nut Green Power Cord Ground Wire 1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner. 2. Install a UL approved strain relief into the power cord entry hole of the mounting bracket . Finger tighten the nut only at this time. 3. Remove the green neutral ground wire from the green ground screw located above the terminal block. Black 240V White Neutral Red 240V Green Ground Typical Conductor Receptacle Typical 4 Conductor Cord 11 English 4. Thread a U.L. approved 30 Amp power cord. NEMA 14-30 type ST or SRDT through the strain relief. 5. Attach the green power cord ground wire to the cabinet with green ground screw. 6. ...
Other models in this manual:Dryers - CGDE700AW (285.6 kb)
Dryers - CGDE700AW (285.6 kb)
Dryers - CGDE700AW (285.6 kb)
Dryers - CGDE700AW (285.6 kb)