Login:
Votes - 3, Average rating: 4 ( )

User manual Alliance Laundry Systems, model Dryer Tumblers

Manafacture: Alliance Laundry Systems
File size: 1.13 mb
File name: 677931af-ea29-4ec7-9f4b-b0add81dd249.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Gas LL 30 No Governor 25 2.1 1 M401003 30 2.2 1 M401011 T30 2.2 2 M401011 35 2.5 1 M406361 T45 2.5 2 M401007 55 3.0 1 M401017 NL Natural Gas L 25 11.0 25 30 T30 35 T45 55 3.9 4.0 4.0 4.6 4.6 4.8 1 1 2 1 2 1 M402980 M402992 M402992 M411511 M411371 M411372 L.P. Gas B/P 30 No Governor 25 2.1 1 M401003 30 2.2 1 M401011 T30 2.2 2 M401011 35 2.5 1 M406361 T45 2.5 2 M401007 55 3.0 1 M401017 Table 1 (continued) Burner orifice information at 0-600 meters (0-2000 feet) altitude. © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT 70392201 (EN) Installation/Operation Supplement Table 1 (continued) Country Code Gas Type Group Supply Pressure, mbar Burner Orifice Pressure, mbar Capacity/ Model Diameter, mm Quantity Burner Orifice Part No. BE/FR* Natural Gas E+ 20 or 25 No Governor 25 30 T30 35 T45 55 3.9 3.3 3.3 3.7 3.7 4.0 1 1 2 1 2 1 M402980 M401021 M401021 M400998 M401000 M401012 L.P. Gas + 28 or 37 No Governor 25 2.1 1 M401003 30 2.2 1 M401011 T30 2.2 2 M401011 35 2.5 1 M406361 T45 2.5 2 M401007 55 2.8 1 M411512 GB/IE/PT/ ES/IT/GR/ Natural Gas H 20 7.6 8.0 8.0 8.0 8.0 8.0 25 30 T30 35 T45 55 3.9 4.0 4.0 4.6 4.6 5.2 1 1 2 1 2 1 M402980 M402992 M402992 M411511 M411371 M402993 LU/CH L.P. Gas + 28 or 37 No Governor 25 2.1 1 M401003 30 2.2 1 M401011 T30 2.2 2 M401011 35 2.5 1 M406361 T45 2.5 2 M401007 55 2.8 1 M411512 AT Natural Gas H 20 7.6 8.0 8.0 8.0 8.0 8.0 25 30 T30 35 T45 55 3.9 4.0 4.0 4.6 4.6 5.2 1 1 2 1 2 1 M402980 M402992 M402992 M411511 M411371 M402993 L.P. Gas B/P 30 No Governor 25 2.1 1 M401003 30 2.2 1 M401011 T30 2.2 2 M401011 35 2.5 1 M406361 T45 2.5 2 M401007 55 3.0 1 M401017 L.P. Gas B/P 30 No Governor 25 2.1 1 M401003 30 2.2 1 M401011 CY/IS/MT T30 35 2.2 2.5 2 1 M401011 M406361 T45 2.5 2 M401007 55 3.0 1 M401017 Table 1 (continued) Burner orifice information at 0-600 meters (0-2000 feet) altitude. *For Natural Gas, Group E+ applications, convert using L.P. Gas model and replace burner orifice. 70392201 (EN) © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT Installation/Operation Supplement Table 1 (continued) Country Code Gas Type Group Supply Pressure, mbar Burner Orifice Pressure, mbar Capacity/ Model Diameter, mm Quantity Burner Orifice Part No. HU Natural Gas H 25 7.6 8.0 8.0 8.0 8.0 8.0 25 30 T30 35 T45 55 3.9 4.0 4.0 4.6 4.6 5.2 1 1 2 1 2 1 M402980 M402992 M402992 M411511 M411371 M402993 L.P. Gas B/P 30 No Governor 25 2.1 1 M401003 30 2.2 1 M401011 T30 2.2 2 M401011 35 2.5 1 M406361 T45 2.5 2 M401007 55 3.0 1 M401017 PL Natural Gas H 20 7.6 8.0 8.0 8.0 8.0 8.0 25 30 T30 35 T45 55 3.9 4.0 4.0 4.6 4.6 5.2 1 1 2 1 2 1 M402980 M402992 M402992 M411511 M411371 M402993 L.P. Gas 3P 37 No Governor 25 2.1 1 M401003 30 2.2 1 M401011 T30 2.2 2 M401011 35 2.5 1 M406361 T45 2.5 2 M401007 55 2.8 1 M411512 Table 1 Burner orifice information at 0-600 meters (0-2000 feet) altitude. © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT 70392201 (EN) Installation/Operation Supplement Exhaust Requirements WARNING A drying tumbler produces combustible lint. To reduce the risk of fire, the tumbler must be exhausted to the outdoors. W057 To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumbler air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed space of a building. W059 Make-Up Air IMPORTANT: Do not obstruct the flow of combustion and ventilation air. A tumbler is forced air exhausted and requires provisions for make-up air to replace the air exhausted by the tumbler. The required make-up air opening to the outside for each tumbler is: 709 sq. cm (110 sq. in.) for 25 and 30 pound models 928 sq. cm (144 sq. in.) for 35 and 55 pound models 1418 sq. cm (220 sq. in.) for T30 models 1856 sq. cm (288 sq. in.) for T45 models Make-up air openings with louvers will restrict airflow. The opening must be increased to compensate for area taken up by louvers. If it is necessary to duct make-up air to the tumbler(s), increase the area of the ductwork by 25% to compensate for any restriction in air movement. Venting Proper sized exhaust ducts are essential for proper operation. All elbows should be sweep type. Exhaust ducts must be assembled so the interior surfaces are smooth to prevent the accumulation of lint. DO NOT use plastic or thin foil flexible ducts. Use exhaust ducts made of sheet metal or other noncombustible material. Use duct tape or pop-rivets on all seams and joints. Verify that old ducts are thoroughly cleaned out before installing new tumbler. NOTE: The ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 0.495 mm (0.0195 inches) thick. IMPORTANT: For best performance, provide an individual exhaust duct for each tumbler. Do not install a hot water heater in room containing tumblers. It is better to have the water heater in a separate room with a separate air inl...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category