Login:
Votes - 4, Average rating: 4.3 ( )

User manual Porter-Cable, model BAMMER CMS200

Manafacture: Porter-Cable
File size: 16.57 mb
File name:
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


Do not use liquid lubricants on this tool. CLEAN AND INSPECT DAILY CAUTION: Remove fuel cell and purge tool before cleaning and inspection. Correct all problems before placing the tool back in use. EXTERIOR Wipe tool clean and inspect for wear or damage. If necessary, use a solution of warm water and dish washing detergent to wipe exterior of tool only. DO NOT SOAK tool with cleaning solution. Do not use solvents on tool, this can damage internal parts. Do not use oil or grease on this tool except as specified in this manual. Inspect trigger and compression mechanism to assure system is complete and functional: no loose or missing parts, no binding or sticking parts. Keep all screws tight. Loose screws can cause personal injury or damage tool. FASTENER GUIDE AREA Open the quick release latch and hinge the fastener guide plate open (see Fig. 25). Clean this area thoroughly. Residue from the fastener collation material collects in this area and must be cleaned regularly. A light coat of a “dry” lubricant (like Porter-Cable #1255066) may be applied to the driver guide track. USE “DRY” LUBRICANT ONLY! AIR FILTER This tool is equipped with a foam air filter. This filter will require changing periodically. Frequency will depend on the amount of airborne contaminants in the operating area. The filter should be changed at least as often as the igniter. Each replacement igniter kit includes a new air filter (and a tube of silicone lubricant). The filter is also available separately. A clogged filter will cause the tool to misfire. Change the filter as follows: 1. CAUTION: Remove regulator and purge tool. 2. Remove four top cover screws (A) Fig. 27, and lift off cover. 3. Brush any foreign material from exposed area. 4. Pull wire and boot assembly off spark plug (see Fig. 28). 5. Lift old filter out, clean any foreign material from filter area. 6. Insure new filter is lightly oiled with automotive oil SAE 5 or 10, or equivalent (do not use multi viscosity oil). It is highly recommended that air filters always be replaced when they require servicing. However, if a new air filter is not available, the filter can be washed in a solution of warm soapy water, thoroughly dried, oiled per the above, excess oil blotted with paper towel, and reused. 7. Insert new filter, fill spark plug cavity with electrical grade silicone lubricant (like Porter-Cable #883807), and firmly seat wire and boot back onto spark plug. 9 8. Replace top cover and secure with the four screws removed in step 2. SERVICE AND REPAIRS All quality tools eventually require servicing or replacement of parts due to wear from normal use. Some user serviceable components are described in the TROUBLESHOOTING Section. Complete product Service is available from either an AUTHORIZED PORTER-CABLE SERVICE STATION or a PORTER-CABLE SERVICE CENTER. AH repairs made by these agencies are fully guaranteed against defective, material and workmanship. We cannot guarantee repairs made or attempted by anyone other than these agencies'.., Should you have any questions about your tool, feel free to write us at any time. In any communications, please give all information shown on the nameplate of your tool (model number, type, serial number, etc.). TROUBLESHOOTING GUIDE CAUTION: Disconnect regulator from tool before cleaning and inspection. - ' Problem __Possible Reasons and Solutions_._ TOOL DOES NOT RETURN • New tool has not been broken-in. Use tool in normal, TO EXTENDED POSITION right-side-up position to fire the first fifty to one WHEN HELD UPSIDE DOWN - hundred fasteners. The tool should then operate upside down. • Tool is too cold. Fire a few fasteners in the right-side-up position to warm mechanism. TOOL FIRES BUT NO • There are no fasteners loaded in the magazine. FASTENERS COME OUT Insertfasteners into magazine. • Fasteners are improperly installed. Remove fasteners and replace correctly. See “Operating Instructions” for details. , • Incorrect fasteners are being used. Verify approved fasteners of correct size as described in “Accessories” section. • Fastener is jammed under the nose cover. Open the nose cover by releasing the quick-release latch and remove any jammed fasteners. Replace cover. (See “Frequent Jamming” problem below.) • Tool has been held to contact surface too long and gas has dissipated from chamber not allowing for sufficient firing force. Repeat firing cycle. • Spring is kinked. Make sure fasteners are being . ■ ■.. • pushed forward throughout the entire range. If the - . spring needs to be replaced, please contact a Porter-Cable authorized service center. 10 TRIGGER DOES NOT PULL BACK TRIGGER PULLS, BUT TOOL DOES NOT FIRE TOOL FAINTLY SMELLS OF GAS, “ROTTEN EGGS” TOOL WILL NOT COMPRESS TOOL WILL NOT EXTEND w/out HELP FROM OPERATOR FASTENER DOES NOT COUNTER-SINK FREQUENT JAMMING EXCESSIVE GAS VENTING (Includes hissing sound, regulator is very cool, intense smell of “rotten eggs”) REGULATOR IS DIFFI...

Other models in this manual:
Nail Guns - BAMMER 892321-8910 (16.57 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category