Login:
Votes - 5, Average rating: 4.4 ( )

User manual Campbell Hausfeld, model FP2049

Manafacture: Campbell Hausfeld
File size: 2.26 mb
File name:
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


15. Do not smoke when spraying paint, insecticides, or other flammable substances. 16. Use a face mask/ respirator when spraying and spray in a well ventilated area to prevent health and fire hazards. 17. Do not direct paint or other sprayed material at the compressor. Locate compressor as far away from the spraying area as possible to minimize overspray accumulation on the compressor. 18. When spraying or cleaning with solvents or toxic chemicals, follow the instructions provided by the chemical manufacturer. ! WARNING ! WARNING ! DANGER Installation LOCATION It is extremely important to use the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F. A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct air flow. Do not locate the compressor air inlet near steam, paint spray, sandblast areas or any other source of contamination. This debris will damage the motor. GROUNDING INSTRUCTIONS 1. This product is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in Fig. 1. Make sure the product is connected to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit, grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. Improper use of grounding plug can result in a possible risk of electrical shock! ! DANGER ! CAUTION TEST RESET Figure 1 - Grounding Method Grounding Pin Grounded Outlet Para Ordenar Repuestos Sirvase Llamar al Distribuidor Mas Cercano A Su Domicilio 1 Cubierta con mango FP204822AV 1 2 (a, b) Ensamblaje del mango FP204823AV 1 3 Manometro del tanque FP204012AV 1 4 Regulador FP204013AV 1 5 Multiple FP204835AV 1 6 Valvula de seguridad V-215102AV 1 7 Interruptor FP204824AV 1 8 Llave de drenaje D-1403 1 9 Ensamblaje de la bomba/motor FP204825AV 1 10 Presostato FP204836AV 1 11 Kit de tubo de escape FP204826AV 1 12 Tornillos de la tapa - Articulo estandar M6-1.0 x 20 de ferreteria 4 13 Manguera de 7,6 m (25 pies) MP302700AV 1 14 Juego de herramientas (5 piezas)FP204008AV 1 15 Valvula de chequeo FP204827AV 1 16 Cubierta de almacenamiento FP204828AV 1 17 Juego de etiqueta adhesiva (no se muestra) FP204829AV 1 18 (a, b) Kit de aislador FP204830AV 1 19 (a, b) Guarda de bomba/motor FP204831AV 1 20 Filtro FP204832AV 1 21 Patas de caucho FP204833AV 1 22 Cordon electrico FP204834AV 1 1 12 13 7 2a 14 2b 18a 18b 19a 19b 20 2b 16 11 4 5 8 21 10 22 15 6 9 3 Sirvase darnos la siguiente informacion: Puede escribirnos a: -Numero del modelo Campbell Hausfeld / Attn: Parts Department -Numero de Serie (de haberlo) 100 Production Drive -Descripcion y numero del repuesto segun la lista de repuestos Harrison, OH 45030 U.S.A. Liste de Repuestos FP204800, FP204900 No. de Numero No. de Numero Ref. Descripcion de pieza Ctd. Ref. Descripcion de pieza Ctd. Compr esor es Sin Aceit e Guia de diagnostico de averias (Continuacion) Problema Posible(s) Causa(s) Accion a tomar Exceso de humedad en 1. Demasiada agua en el tanque el aire de descarga 2. Humedad elevada 1. Drene el tanque, incline el tanque para eliminar la humedad 2. Llevelo a un area menos humeda, utilice un filtro de aire de linea Nota: La condensacion de agua no es una causa para el malfuncionamiento del compresor. El compresor funciona 1. Presostato defectuoso 1. Cambie el interruptor de presion en forma continua y la 2. Valvula de seguridad defectuosa 2. Cambie la valvula de retencion con un repuesto valvula de seguridad se original abre cuando aumenta la presion Arranques y paradas 1. Demasiada condensacion en el excesivas tanque 2. Conexiones flojas (accesorios, tuberia, etc.) 22 Sp 1. Drene con mas frecuencia 2. Revise todas las conexiones con una solucion de agua y jabon. Si se detecta una fuga, apriete. O quite la conexion y aplique cinta para tuberias a las rocas y vuelva a armar. FP2048, FP2049 Installation (Continued) ! DANGER Do not use a grounding adapter with this product! 2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire. Never connect ! WARNING green (or green and yellow) wire to a live terminal. 3. Check with a qualified electrician or serviceman if grounding instructions are not completely understood, or if in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician. Overheating, short ! CAUTION circuiting and fire damage will result from inadequate wiring, etc. Ope...

Other models in this manual:
Nail Guns - FP2048 (2.26 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category