Manafacture: Alliance Laundry Systems
File size: 6.25 mb
File name: 9d66fe64-515f-c214-c11e-666e5351313f.pdf
|
manual abstract
installation electrolux 41 If you require any further advice please contact your local water authority. %&'()*+&%,-+',#+,+(*%&,./*&,,%&(*%&))*,(*+)0)12'330%1)3*(*+))*,%4%()%1+)*+,%&*).),5)3'1#)*,3'1#%()%%(*.+)*+/+(')-%),5) +)*+,%&*). Electrical connection Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person. Important! This appliance must be earthed. The manufacturer declines any liability should this safety measure not be observed. Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance’s rating plate. Important! Information on the electrical connection is given on the rating plate on the inner edge of the appliance door. The appliance is supplied with a 13amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved (BS1363/A) fuse must be used. Should the plug need to be replaced for any reason, proceed as described below. The wires in the mains lead are coloured in accordance with the following code: Green and Yellow......................- Earth Blue ..........................................Neutral Brown ......................................- Live !"##. %#&&'. )"'(. *'"+*&,. . The wire coloured green and yellow must be connected to the terminal marked with the letter «E» or by the earth symbol or coloured green and yellow. 42 electrolux installation The wire coloured blue must be connected to the terminal marked «N» or coloured black. The wire coloured brown must be connected to the terminal marked «L» or coloured red. Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath. Warning! A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely. Should the appliance power supply cable need to be replaced, this MUST be carried out by a Service Force engineer. The power supply cable must be easily accessible after installing the appliance. Permanent connection In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations. The switch must not break the yellow and green earth cable at any point. Building-in This appliance has been designed to be built into the kitchen furniture. The recess should have the dimensions shown in picture A. building-in electrolux 43 In this case it is sufficient to screw in the hinges (1) and the counter-magnet (6) provided with the appliance, at the right level (Fig. B). When installing the appliance into the kitchen furniture ensure, if possible, the hoses are placed in either of the two recesses on the back of the appliance. This will help to prevent the hoses from becoming kinked or trapped. Picture AB. a) Door The dimensions of the door should be: -width 595-598 mm -thickness 16-22 mm The height (C-Fig. C) depends on the height of the adjacent furniture's base. ./0/ 1. . Preparation and assembly of the door The machine is originally pre-arranged for the assembly of a door opening from right to left. b) Hinges To mount the hinges it is necessary to drill two holes (dia. 35 mm, depth 12.514 mm depending on the depth of door furniture) on the inner side of the door. The distance between the holes hobs fixing centres must be 416 mm. 44 electrolux building-in The distance (B) from upper edge of the door to the centre of the hole depends on the adjacent furniture's dimensions. The required dimensions are given in the picture C. The hinges will be fixed to the door by means of screws for wood (2-Fig. B) supplied with the appliance. c) Mounting the door Fix the hinges (1) to the machine by means of the M5x15 screws (3-Fig. B). The hinges can be adjusted to compensate for possible uneven thickness of the door. To align the door perfectly it is necessary to loosen the screw (3-Fig. B), adjust the door and tighten the screw again. d) Counter-magnet (6) The appliance is designed for a magnetic closure of the door. To enable the correct operation of this device, it is necessary to screw the counter-magnet (6) (steel disk + rubber ring) into the inner side of the door. Its position must correspond to the magnet (4) on the appliance (see picture D). If the door has to be opened from left to right, invert the position of the plates (7), the magnet (4) and the plate (5) (Fig. B and E). Mount the counter-magnet (6) and the hinges (1) as previously described. Recommendations regarding the construction and fitting of a base when the installation requires an integrated appliance to be raised. Where the appliance has been raised by mounting onto a wooden base provided by the installer. The material used to construct the base should have ...