User manual York, model WORLD 50 HZ K3EU180A50

Manafacture: York
File size: 163.92 kb
File name: af8b6a52-ce66-4156-bb4d-be14c2a5ddb6.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


A (0501) MODEL K3EU180A50 (WORLD 50 HZ) GENERAL This completely assembled blower unit is manufactured under ISO 9002 Quality System Certification and includes a well- insulated cabinet, a DX cooling coil with copper tubes and aluminum fins, an expansion valve, a distributor, throwaway filters, a centrifugal blower, a blower motor, a blower motor contactor, an adjustable belt drive and a small holding charge of Refrigerant-22. The unit is shipped in the vertical position with a vertical air discharge. The blower section can be repositioned as shown in Figure1 for horizontal applications. REFERENCE This instruction covers the installation of the evaporator blower unit. For information on the installation and operation of the matching condensing unit refer to Form 035-17263-000. Additional information for the accessories on this equipment is available in the following instructions: • Electric Heater - 550.13-N10.1V • Supply Air Plenum - 550.13-N10.2V • Return Air Grille - 550.13-N10.3V • Base - 550.13-N10.4V • Hot Water & Steam Coil - 550.13-N10.7V • Suspension Mounting - 550.13-N7.1 INSPECTION As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's delivery receipt. A separate request for inspection by the carrier's agent should be made in writing. See Local Distributor for additional information. NOMENCLATURE K 3 EU 180 A50 Product Category K = Split-System Evaporator Blower Product Generation 1,2,3 = Design Level Product Identifier EU = Evaporator Blower Unit Nominal Cooling Capacity 180 = 180Mbh (52.7kW) Refrigerant Line Connections A = Cooling Only Voltage Code 50 = 380/415-3-50 Renewal Parts: • Refer to Parts Manual for complete listing of replacement parts on this equipment. All forms may be ordered from: Standard Register 2101 West Tecumseh Road Norman, OK 73069 CAUTION THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES. THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH WARNING OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE. INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes are intended to clarify or make the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal injury and/or equipment damage may result if installation procedure is not 035-12124-000 Rev. A (0501)I INSTALLATION LIMITATIONS These units must be installed in accordance with applicable national, local and municipal safety codes. If components are to be added to a unit to meet local codes, they are to be installed at the dealer's and/or the customer's expense. Refer to Table 2 for Unit Application Data. LOCATION This blower unit is not designed for outdoor installation. It must be located within the building structure, either inside or outside the conditioned space. The unit should be located as close to the condensing unit as practical and positioned to minimize bends in the refrigerant piping. Units being installed vertically or horizontally can be set directly on a floor or platform, or they can be supported by metal or wooden beams. Units being installed horizontally can also be suspended from above. Refer to the suspension accessory instruction installation procedures. CLEARANCES The clearances listed on the unit dimension drawing (Figure 7) are required for the proper service and operation of the unit. RIGGING AND HANDLING Be careful when moving the unit. Do not remove any packaging until the unit is near its final location. The packaging consists of a bottom wooden skid that can be lifted with a fork truck from any direction, a clear heavy mil bag that covers the entire unit, and strapping that secures the clear bag to the bottom of the skid. These units can be rigged with slings under the bottom skid. CAUTION: Spreader bars should be used to prevent slings from crushing the unit panels and frame. Before rigging any unit, determine its weight from Table 1. Before rigging a unit for horizontal installation, make sure that its weight will be distributed equally. Table 1 - PHYSICAL DATA Evaporator Coil Rows Deep 4 Rows High 26 Finned Length (in./mm) Fin/Inch 54.5/1384 13 Tube O.D. (in./mm) 3/8/9.6 Face Area (Ft.2/m2) 12.4/1.15 Centrifugal Blower1 Wheel Dia. x Width inches 18 x 18 mm 457 x 457 Filters2 (6 Req'd) Size inches 20 x 20 x1 mm 508 x 508 x 25 Face Area (Ft.2/m2) 16.7/1.5 Operating Charge ( Refrigerant 22) (Lbs/Kg) 5.5/2.5 Weight (Lbs/Kg) Shipping 480/218 Operating 440/200 Accessory Weights(Lbs/Kg) Electric Heaters 10 kW 63/28.5 16 kW 66/29.9 26 kW 71/32.2 36 kW 74/33.5 Supply Air Plenum 144/65 Base 65/29 Return Air Grille 19/9 Horizontal Suspension 68/31 Steam Coil 149/68 Hot Water Coil 135/61 1Refer to data in Tab...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category