manual abstract
All factors which contribute to whitefinger disease are not known, but cold weather, smoking diseases or physical conditions as well as long periods of exposure to vibration are mentioned as factors. In order to reduce the risk of whitefinger disease, the following precautions are strongly recommended. a: Keep your body warm. Never use blower during rains. b: Wear thick anti-vibration gloves. c: Take more than 5 minutes of break in warm place frequently. d: Maintain a firm grip at all times, but do not squeeze the handles with constant, excessive pressures. e: If you feel discomfort, redness and swelling of your fingers or any other part of your body, see a doctor before getting worse. ¦ Maintenance 1. In order to maintain your product in proper working order, perform the maintenance and checking operations described in the manual at regular intervals. 2. Always be sure to turn off the engine and disconnect the spark plug before performing any maintenance or checking procedures. fasteners and rusted or damaged parts. Use special care around the fuel line, the muffler, and the ignition wiring. 4. When replacing the any other part, or any lubricant, always be sure to use only RedMax products or products which have been certified by RedMax for use with the RedMax product. 5. In the event that any part must be replaced or any maintenance or repair work not described in this manual must be performed, please contact a representative from the store nearest RedMax authorized servicing dealer for assistance. 6. Do not use any accessory or attachment other than those bearing the RedMax mark and recommended for the unit. 7. Under no circumstances should you ever take apart the product or alter it in any way. Doing so might result in the product becoming damaged during operation or the product becoming unable to operate properly. ¦ Disposal When disposing your machine, fuel or oil for the machine, be sure to allow your local regulations. U S WARNING The metallic parts and engine cover reach high temperatures immediately after stopping the engine. 3. Examine the blower at intervals for loose US-7 F4 [EBZ5150RH] [ R+M ] 2 50:1 MIXING CHART GASOLINE gal. 1 2 3 4 5 2-CYCLE OIL fl.oz 2.6 5.2 7.8 10.4 13 GASOLINE liter 1 2 3 4 5 2-CYCLE OIL ml 20 40 60 80 100 F10 5. To start, hold the top of the blower firmly with your left hand. Pull the starter knob slowly until you feel it engage and then give it a vigorous strong pull. (F10) IMPORTANT •Avoid pulling the starter rope out to its full extent and allowing the starter rope to snap back. This will prevent premature damage to the starter. • Do not let a person stand near the blower or the exhaust port. 6. Once the engine is running, gradually open the choke if it was set closed, and let the engine run at idle speed for a minute to warm it up. NOTE When the engine fails to start after several attempts due to overchoking, open the choke and repeat pulling the rope. F7 F8 [EBZ5150RH] EBZ5150/RH 8. Operation ¦ ADJUSTING THE SHOULDER STRAPS Tightening: • Pull on the end of the strap. F11 F12 F13 (1) F14 Loosening: • Pull up on the lower portion of the buckle with a finger and slide the end of the strap back up to the buckle. ¦ EMERGENCY REMOVAL • In an emergency, pull up on the lower portion of both strap buckles to loosen the straps. Move yourself away from the unit. ¦ ADJUSTING IDLE SPEED (F14) • The idling speed is set for 2000 rpm at the factory. If it is necessary to adjust the idle speed, use the adjustment screw on the top side of carburetor. (1) Idling Adjustment Screw (1) F15 [EBZ5150] (1) F16 [EBZ5150RH] ¦ STOPPING ENGINE [EBZ5150] •Move the throttle lever to the idling position and press the stop switch (red button). The machine has the mechanism that once the stop button is pushed the plug won't give off sparks until the engine stops. (F15) (1) Stop Switch [EBZ5150RH] •Move the throttle lever to the idling position and set the ignition switch to the stop position. (F16) (1) Ignition Switch F17 NOTE If the engine won’t stop when setting the ignition switch to the stop position, close the choke lever and stop the engine. In this case, please repair the machine at your nealest servicing dealer. (F17) (1) Choke Lever (2) OPEN (3) CLOSE US-12 F19 System/Compornent Procedure Daily or Before use Every 25 hours after Every 50 hours after Every 100 hours after Air Filter Inspect/Clean . Fuel Leaks Inspect/Replace . Fuel Filter Inspect/Replace . . Fuel Line Inspect/Clean . Spark Plug Inspect/Clean . Muffler Inspect/Clean . Muffler Spark Arrester Inspect/Clean . Cooling System Inspect/Clean . Screws/Nuts/Bolts Tighten . Cylinder Exhaust Port Inspect/Clean . WARNING Make sure that the engine has stopped and is cool before performing any service to the blower. Contact with rotating blower fan or hot muffler may result in a personal injury. ¦ AIR CLEANER • Never operate the blower without an air filter or with a deformed or broken filter element because unfiltered dusty air will quick...
Other models in this manual:Blower systems - EBZ5150 (527.22 kb)