Manafacture: Air King
File size: 137.09 kb
File name:
|
manual abstract
Figure 1 Figure 2 210952009 Rev. B 2-06 2 of 8 Joist Housing Hanger Bar Figure 3 Joist 1b. Internal Wire Compartment: Remove the screw holding the venturi 4. Carefully tuck wire back inside wire compartment and replace wire in place. Lift the venturi up and at an angle to slide it out of the compartment cover securing with the screw that was removed earlier. housing (Figure 6). Remove the wire compartment cover screw and place the cover in a secure place (Figure 7). SECTION 6 NOTE: If the fan motor plug is connected to the fan housing receptacle, unplug so the venturi can be completely removed. Figure 6 Plug Screw Venturi Completing the Installation 1. If the fan’s blower assembly was removed during the wiring process, reinstall the blower by reversing the directions in Step 1bin Section 5 Wiring. 2. Plug the fan’s quick connect motor cord into the receptacle. This cord will only fit one way into the receptacle (Figure 9). Figure 7 Screw Wire Compartment Cover 2. Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and one hot (black lead connected to the switch). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle. 3. From where you have chosen to access the fan’s junction box, connect the White wire from the house to the White wire from the fan’s receptacle. Connect the Black wire from the wall switch to the Black wire from the fan’s receptacle. Connect the ground wire from the house to the Green wire from the fan’s receptacle (Figure 8). Use approved methods for all connections. 4. Restore power and test your installation. NOTE: The fan’s receptacle wires might need to be pulled outside compartment for connection. Only pull the three loose wires outside of compartment. Additional wires will be present. Figure 8 Ground Hot (Black) White Supply from house SECTION 7 Use and Care CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT. 1. Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions in Section 6 Finishing the Installation, to reinstall grill. 2. Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER. Troubleshooting Guide Figure 9 3.Install the grill by squeezing the two ends of the springs together and installing them up into the slots on the fan’s housing. Push the grill up into position (Figure 10). Figure 10 Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. 2. Fan is operating, but air moves slower than normal. 3. Fan is operating louder than normal. 1a. A fuse may be blown or a circuit tripped. 1b. Connector plug f...
Other models in this manual:Blower systems - AK110PN (137.09 kb)
Blower systems - AK110 (137.09 kb)
Blower systems - AK50LS (137.09 kb)
Blower systems - AK80 (137.09 kb)