|
manual abstract
114 00 25-95 CONTENTS Introduction ......................................... 3 Key to symbols....................................4 Safety instructions .............................. 5 Description .......................................... 7 Fuel handling ..................................... 12 Start and stop .................................... 14 Using the blower ............................... 16 Maintenance ...................................... 20 Technical data....................................25 Maintenance, replacement, or repair of the emission control devices and systems may be performed by any nonroad engine repair establishment or individual. 2 – English INTRODUCTION Husqvarna AB has a policy of continuous product development and therefore reserves the right to modify the design and appearance of products without prior notice. This operator’s manual describes in detail how to use and service the blower and how to carry out regular maintenance. It also describes which measures should be taken to achieve maximum safety while operating the blower, how the safety devices work and how they should be serviced. Note! The section of the manual that deals with safety, must be read and understood by all persons who come in contact with the blower. This operator’s manual has been written for those who need guidance when it comes to fault tracing, thorough servicing and carrying out corrective maintenance of the blower. There are warning symbols on the blower. These are illustrated on page 3. Should any of the warning symbols on the blower become disfigured or worn, new ones should be ordered and fitted to the blower as soon as possible. Note that some of the warning symbols are molded in certain components of the blower. The blower is used for blowing away leaves and other debris on the ground. When operating the blower, the operator must stand with both feet firmly on the ground. This decal certify that the product has been approved in accordance with American exhaust emission requirements EPA 1 and CARB 95. ! ! WARNING! Under no circumstances may the design of the machine be modified without the permission of the manufacturer. Always use genuine accessories. Non-authorised modifications and/or accessories can result in serious personal injury or the death of the operator or others. Your warranty does not cover damage or liability caused by the use of non-authorized accessories or replacement parts. English – 3 KEY TO SYMBOLS Symbol Description Location BlowerOperator’s manual Symbol Description Location Blower The blower operator must make sure that no bystanders or animals come nearer than 10 metres. Whenever several operators are working in the same work area, they should maintain a safe distance of at least 10 metres from one another. Choke. Refueling. Stop switch. The manufacturer’s warrantee for this product meets safety requirements according to: •The Machine Directive •The EMC Directive •The Low Voltage Directive Instructions on how to open the inspection cover. Noise pressure level measured at 15 metres distance according to ANSI B175.2-1996. Operator’s manualX X X X X X X X X70dB (A) per ANSI B175. 2-1996 Other symbols/decals on the machine refer to special certification requirements for certain markets. Checks and/or mainten-ance shall be carried out after having switched off the engine. The stop switch must be set to the STOP position. Cleaning at regular intervals is required. X X Approved protect goggles or visor must be worn. X Approved protect goggles or visor and ear protection must be worn. X X WARNING! The blower can be dangerous! Careless or improper use can cause serious, even fatal injury. Read the operator’s man-ual carefully and make sure that you understand the contents before using the blower. WARNING! Make sure that the inspection cover is locked in the closed position or that the vacuum tube is mounted on the blower. Never touch the impeller. X X X X X X WARNING! The blower may throw objects at high velocity that can ricochet and hit the operator. This may cause serious eye damage. X X 4 – English SAFETY INSTRUCTIONS 3 Personal safety equipment Persons who use the blower shall wear the following safety equipment: 1. Approved ear protection. 2. Approved eye protection. 3. Face mask when operating the blower in dusty environments. 4. Boots or work shoes with a non-slip sole. 5. First-aid kit. 1+2 4 5 Personal safety The following instructions apply to persons operating the blower: 1. The operator shall have read and understood the contents of this manual. 2. Do not wear loose clothing, scarves or neck chains or let long hair hang loose, since these can be drawn into rotating parts of the blower and cause injury. 3. Do not operate the blower while under the influence of alcohol, drugs or when you are tired. 4. Do not allow minors to operate the blower. Fuel safety ! ! WARNING! The fuel used to run the blower has the following dangerous charact-eristics: 1. Volatile liquid, its v...
Other models in this manual:Blower systems - 225B X-Series (718.95 kb)