|
Other manuals for this model:
manual abstract
Security After you plug in your new AV adapter, press the Button Security button for 2 seconds, then press the security button on one of the other AV adapters in your existing network for 2 seconds. Both buttons must be pressed within 2 minutes. Note: The Security button does not work in power saving mode. Power saving mode occurs when the Ethernet LED is off. To return to normal mode from power saving mode, check your Ethernet connection. Once the Ethernet link is up, the Powerline adapter will return to normal mode within 2 seconds. Warning: Do not press the Security button on the Powerline adapter until installation is complete and the adapters are communicating with each other (indicated by the blinking Powerline LED). Pressing this button too soon can temporarily disable Powerline communication. If this should occur, use the Factory Reset button to return the Powerline adapter to its factory default settings. Warning: To reduce the torque on the AC outlet caused by the weight of the XAV5501, only a right-angled power cord can be plugged in to the filtered AC socket of the XAV5501 GR (German) and FR (French), and the power cord cannot be bent. Troubleshooting Tips For troubleshooting information, see the XAV5501 User Manual. You can access the User Manual from Search for the XAV5501 product model and click the Documentation tab. Technical Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of your product and use it to register your product at Registration is required before you can use our telephone support service. Registration via our website is strongly recommended. Go to for product updates and Web support. GPL may be included in this product; go to ftp://downloads.netgear.com/files/GPLnotice.pdf to view the GPL license agreement. For complete DoC, please visit the NETGEAR EU Declarations of Conformity website at: kb.netgear.com/app/answers/detail/a_id/11621 This symbol was placed in accordance with the European Union Directive 2002/ 96 on the Waste Electrical and Electronic Equipment (the WEEE Directive). Ifdisposed of within the European Union, this product should be treated andrecycled in accordance with the laws of your jurisdiction implementing theWEEE Directive. ©2011 by NETGEAR, Inc. All rights reserved. NETGEAR, the NETGEAR logo, and Connectwith Innovation are trademarks and/or registered trademarks of NETGEAR, Inc.and/or itssubsidiaries in the United States and/or other countries. Information is subject to changewithout notice. Other brand and product names are trademarks or registered trademarks oftheir respective holders. August 2011 Installation Guide Powerline AV+ 500 Adapter XAV5501 Package Contents Powerline AV+ 500 Adapter Ethernet cable Compatible Powerline and HomePlug AV certified devices include the NETGEAR XAV101, XAV1004, XAV1501, XAV2001, XAV2501, and XAVN2001. For a complete list of AV certified devices, go to Safety Information Room 1 Room 2 • For national approvals (approval schemes other than CB), relevant national standards for plug, socket-outlet and directplug-in units (for example, US) shall also be consulted whiletesting and approving such products according to nationalstandards. • AC input rating (NA):100-125V, 0.2A (Max), 50–60Hz excluding socket outlet rating. • AC input rating (AU, UK, FR, EU, SW): 200-250V, 0.2A (Max), 50–60Hz excluding socket outlet rating. • XAV5501 ratings (maximum load): EU: 15A 250V~, UK: 12A 250V~, FR: 15A, 250V~, NA: 14A 125V~, AU: 9A, 250V~, SW: 10A, 250V~. • Operating temperature: 0C~40C • The socket-outlet shall be installed near the equipment and beeasily accessible. • Only power cords are allowed to be inserted into the EUTsocket-outlet; no other equipment with a direct plug-in isallowed. Power cord needs to be a maximum of 1 m long and aminimum of 0.75 mm square of cross-sectional area. • Do not plug devices into the XAV5501 filtered AC outlet thatexceed the product ratings. The output voltage of the filteredAC outlet is the same as the power outlet which the XAV5501is plugged into. To help avoid damaging your system, be surethat the attached devices are electrically rated to operate withthe power available in your location. • If the input AC voltage is less than 125Vac, the device pluggedinto the filtered AC socket of the XAV5501 may not perform aswell as expected. • DO NOT PLUG MAJOR HOME APPLIANCES into the filtered AC socket or into an attached powerstrip. The device is notintended to be used with home appliances such as airconditioners, power tools, space heaters, fans, hair dryers, ovens, or refrigerators. • Check the electrical current for any appliance used with thedevice, and do not exceed home and product outlet ratings andelectrical requirements. ...