|
User manual Agilent Technologies, model Agilent 4396B
Manafacture: Agilent Technologies File size: 1.06 mb File name: 04396-90051.pdf
Language of manual:
|
|
|
|
Free link for this manual available at the bottom of the page
manual abstract
The latest edition comes with the product. 1-2 Installation and Setup Guide /f\Replacing Fuse Fuse Selection Select proper fuse according to the Table 1-2. Table 1-2. Fuse Selection Fuse Rating/Type Fuse Part Number 5A 250Vac UL/CSA type Time Delay 2110-0030 For ordering the fuse, contact your nearest Agilent Technologies Sales and Service Office. T 1 Lever a small minus screwdriver to dismount the fuse holder above the AC line receptacle on the rear panel. To check or replace the fuse, pull the fuse holder and remove the fuse. To reinstall the fuse, insert a fuse with the proper rating into the fuse holder. Installation and Setup Guide 1-3 Power Requirements The 4396B requires the following power source: Voltage : 90 to 132 Vac, 198 to 264 Vac Frequency : 47 to 63 Hz Power : 300 VA maximum Power Cable In accordance with international safety standards, this instrument is equipped with a three-wire power cable. When connected to an appropriate ac power outlet, this cable grounds the instrument frame. The type of power cable shipped with each instrument depends on the country of destination. Refer to Figure 1-1 for the part numbers of the power cables available. Warning a|M For protection from electrical shock, the power cable ground ^gl must not be defeated. The power plug must be plugged into an outlet that provides a protective earth ground connection. 1-4 Installation and Setup Guide Figure 1-1. Power Cable Supplied Installation and Setup Guide 1-5 Operation Environment The 4396B must be operated under within the following environment conditions, and sufficient space must be kept behind the 4396B to avoid obstructing the air flow of the cooling fans. Temperature: 0°C to 40°C Humidity: less than 95% RH at 40° C Note Mrl The 4396B must be protected from temperature extremes which could «9 cause condensation within the instrument. Providing clearance to dissipate heat at installation site To ensure the specifications and measurement accuracy of the product, you must keep ambient temperature around the product within the specified range by providing appropriate cooling clearance around the product or, for the rackmount type, by forcefully air-cooling inside the rack housing. For information on ambient temperature to satisfy the specifications and measurement accuracy of the product, refer to “Specifications” in Chapter 10 of the Function Reference. When the ambient temperature around the product is kept within the temperature range of the operating environment specification (refer to “Operation Conditions” in Chapter 10 of the function reference), the product conforms to the requirements of the safety standard. Furthermore, under that temperature environment, it has been confirmed that the product still conforms to the requirements of the safety standard when it is enclosed with cooling clearance as follows: Conditions Rear 180 mm Side 60 mm Instruction for Cleaning To prevent electrical shock, disconnect the 4396B power cable from the receptacle before cleaning. Wipe with a dry cloth or a soft cloth that is soaked with water and wrung tightly without undeue pressure to clean the casing. Do not attempt to clean the 4396B internally. 1-6 Installation and Setup Guide Rack/Handle Installation The analyzer can be rack mounted and used as a component in a measurement system. Figure 1-2 shows how to rack mount the analyzer. Table 1-3. Rack Mount Kits Option Description Agilent Part Number 1CN Handle Kit 5062-3991 1CM Rack Mount Kit 5062-3979 1CP Rack Mount & Handle Kit 5062-3985 Figure 1-2. Rack Mount Kits Installation Option 1CN Handle Kit Option 1CN is a handle kit containing a pair of handles and the necessary hardware to attach them to the instrument. Installing the Handle 1. Remove the adhesive-backed trim strips ® from the left and right front sides of the analyzer. 2. Attach the front handles (3) to the sides using the screws provided. 3. Attach the trim strips @ to the handles. Installation and Setup Guide 1-7 Option 1CM Rack Mount Kit Option 1CM is a rack mount kit containing a pair of flanges and the necessary hardware to mount them to the instrument in an equipment rack with 482.6 mm (19 inches) horizontal spacing. Mounting the Rack 1. Remove the adhesive-backed trim strips ® from the left and right front sides of the analyzer. 2. Attach the rack mount flange © to the left and right front sides of the analyzer using the screws provided. 3. Remove all four feet (lift bar on the inner side of the foot, and slide the foot toward the bar). Option 1CP Rack Mount & Handle Kit Option 1 CP is a rack mount kit containing a pair of flanges and the necessary hardware to mount them to an instrument which has handles attached, in an equipment rack with 482.6 mm (19 inches) spacing. Mounting the Handle and Rack 1. Remove the adhesive-backed trim strips ® from the left and right front sides of the analyzer. 2. Attach the front handle (3) and the rack mount...
|