|
manual abstract
8510 family of system solutions To upgrade from one system to another, simply order the pieces that are needed in the new system that are currently not in the existing system, an example is shown in Figure 9. Complete waveguide S-parameter systems require two test set modules for each band.1 Necessary accessories such as calibration kits, verification kits, test port cables or adapters2 must be ordered. See pages 17 through 19 for more information. 1. The following test set modules are available. Two test set modules must be ordered for complete waveguide S-parameter test set operation for each waveguide band: • Q85104A test set module (33 GHz to 50 GHz) • U85104A test set module (40 GHz to 60 GHz) • V85104A test set module (50 GHz to 75 GHz) • W85104A test set module (75 GHz to 110 GHz) 2. Please refer to the RF & Microwave Test Accessories Catalog (literature number 5964-9527E) on detailed information on available adapters. 13 Here is a checklist of items to consider when upgrading systems: 1. Which 8510 do I have? The 8510C is recommended for the latest available measurement capabilities. • To upgrade an 8510A to an 8510C, order 85103E. • To upgrade an 8510B to an 8510C, order 85103F. • Make sure the appropriate options are ordered. For instance, order Option 010 if the 8510 has previously installed time domain. • Do I need pulse capabilities? If yes, order 85111B for 8510C. 2. What test set do I need? • Refer to Table 3 for test set selection. Frequency range and application type are critical when selecting the appropriate test set. 3. What source do I need? • Refer to Table 3 for the source(s) that’s required for the test set of choice. 4. What measurement accessories do I need? • The appropriate measurement accessories will be determined mainly by the connector type of the device-under-test (DUT). These accessories include calibration (mechanical or electronic), verification kits, test port cables and/or adapters as appropriate. Refer to pages 17 through 19 for available products. System upgrades Upgrades available for existing 8510 systems to 8510XF single-sweep systems 8510C Millimeter subsystem 83651B 83621B Upgrades from ... 85107B 85109C 85106C 85106C w/ Opt.002 85106D 85106C w/ Opt.001 & 002 85106D w/ Opt.001 85109C w/ Opt.002 ... to 85 GHz E7345A E7346A E7347A ... to 110 GHz E7355A E7356A E7357A Customer owned equipment Upgrades for 85107B, 85109C Upgrade consists of two test heads, a millimeter test set controller, an 83621B for LO source, and rack. It does not include calibration kits or test port cables. • E7345A upgrade to an 8510XF 85 GHz system • E7355A upgrade to an 8510XF 110 GHz system The following options are available for both upgrades: • Option 005 add 45 MHz to 2 GHz low frequency extension • Option 006 add RF pass thru (provides coupled output of 50 GHz source for additional test sets. Additional test set(s) must have Option 001 installed.) Upgrades for 85106C, 85106C with Option 002 (replaced 8350B/83540A with 83621A/B), 85106D Upgrade consists of two test heads, a millimeter test set controller and an 83651B for RF source. It does not include calibration kits, test port cables or rack. • E7346A upgrade to an 8510XF 85 GHz system • E7356A upgrade to an 8510XF 110 GHz system The following options are available for both upgrades: • Option 005 add 45 MHz to 2 GHz low frequency extension • Option 006 add RF pass thru (provides coupled output of 50 GHz source for additional test sets. Additional test set(s) must have Option 001 installed.) Upgrades for 85106C with Options 001 and 002 (added 8517B, replaced 83621A/B with 83651A/B, and replaced 8350B/83540A with 83621A/B), 85106D with Option 001 (added 8517B and replaced 83621B with 83651B), 85109C with Option 002 (replaced 8350B/83540A with 83621A/B) Upgrade consists of two test heads and a millimeter test set. It does not include calibration kits, test port cables or rack. • E7347A upgrade to an 8510XF 85 GHz system • E7357A upgrade to an 8510XF 110 GHz system The following options are available for both upgrades: • Option 005 add 45 MHz to 2 GHz low frequency extension • Option 006 add RF pass thru (provides coupled output of 50 GHz source for additional test sets. Additional test set(s) must have Option 001 installed.) Examples of upgrade paths 85107B Upgrade to 85106D waveguide (45 MHz to 50 GHz) system to operate in V-band current system 8510C 8517B 83651B New equipment needed: .85105A1 with Option 0502 millimeter- wave test set controller . 83621B synthesizer (LO source) . V85104A 3 test set modules (quantity of 2) . V11644A 3 calibration kit . V11645A 3 verification kit 8510C 85105A #050 8517B 83651B83621B Figure 10. Upgrading an 85107B 50 GHz system to an 85106D waveguide system to operate in V-band (or W-band) Measurement accessories There are measurement accessories for seven device connector types: 7 mm, 3.5 mm, 2.92 mm, 2.4 mm, 1.85 mm, 1 mm and Type-N. Calibration kits include standards that are required for vector error ...
Other models in this manual:Network Equipment - 85107B (500.62 kb)