|
manual abstract
Send a 0 (zero) following the command to set the channel power measurement in the current setup. Send a 1 (one) to set the channel power associated with the trace that was most recently uploaded by command #36, Upload Sweep Trace. If Option 6 is installed and the frequency converter module is attached, the frequencies should be scaled by the scale factor of the module. If the module is not attached, frequencies are sent in Hz. Use Control Word A203 to determine whether a module is attached and the appropriate scale factor. Note that if the channel power measurement is turned ON, all other measurements (field strength, adjacent channel power) are turned OFF. Bytes to Follow: 14 bytes 1) Channel Power Location (0 = current setup, 1 = last uploaded trace) 2) Channel Power Measurement State (On/Off) 3-6) Center Frequency 7-10) Integration Bandwidth 11-14) Span Frequency Site Master Returns: 1 byte 1) 255 (FFh) Operation Complete Byte 224 (E0h) Parameter Error 238 (EEh) Time Out Error Site Master PM Read Channel Power – Control Byte #86 (56h) Description: Read the current channel power or the channel power of a stored trace. Send a 0 (zero) following the command to read the current channel power measurement (i.e. the one that is updated as the unit is sweeping). Send 1-200 to read the channel power associated with a stored trace (use Query Trace Names, #24, to obtain trace numbers). If Option 6 is installed and the frequency converter module is attached, the frequencies should be scaled by the scale factor of the module. If the module is not attached, frequencies are sent in Hz. Use Control Word A203 to determine whether a module is attached and the appropriate scale factor. Bytes to Follow: 1 byte 1) Channel Power Location (0 = current measured value, 1-200 = value in stored trace) Site Master Returns: 21 bytes 1) Channel Power On/Off 2-5) Channel Center Frequency 6-9) Integration Bandwidth 10-13) Channel Span Frequency 14-17) Channel Power (= (power in dBm * 1000) + 270000) 18-21) Channel Power Density (= (density in dBm/Hz * 1000) + 270000) Set Adjacent Channel Power Ratio (ACPR) – Control Byte #87 (57h) Description: Sets the state of the measurement (ON or OFF), the center frequency, the main channel bandwidth, the adjacent channel bandwidth and the channel spacing. Send a 0 (zero) following the command to set the channel power measurement in the current setup. Send a 1 (one) to set the adjacent channel power associated with the trace that was most recently uploaded by command #36, Upload Sweep Trace. If Option 6 is installed and the frequency converter module is attached, the frequencies should be scaled by the scale factor of the module. If the module is not attached, frequencies are sent in Hz. Use Control Word A203 to determine whether a module is attached and the appropriate scale factor. Note that if the ACPR measurement is turned ON, all other measurements (field strength, channel power) are turned OFF. Bytes to Follow: 18 bytes 1) Adjacent Channel Power Location (0 = current setup, 1 = last uploaded trace) 2) Adjacent Channel Power Measurement State (On/Off) 3-6) Center Frequency 7-10) Main Channel Bandwidth 11-14) Adjacent Channel Bandwidth 15-18) Channel Spacing Site Master Returns: 1 byte 1) 255 (FFh) Operation Complete Byte 224 (E0h) Parameter Error 238 (EEh) Time Out Error Read Adjacent Channel Power Ratio (ACPR) – Control Byte #88 (58h) Description: Read the current adjacent channel power or the adjacent channel power of a stored trace. Site Master PM Send a 0 (zero) following the command to read the current adjacent channel power measurement (i.e. the one that is updated as the unit is sweeping). Send 1-200 to read the channel power associated with a stored trace (use Query Trace Names, #24, to obtain trace numbers). If Option 6 is installed and the frequency converter module is attached, the frequencies should be scaled by the scale factor of the module. If the module is not attached, frequencies are sent in Hz. Use Control Word A203 to determine whether a module is attached and the appropriate scale factor. Bytes to Follow: 1 byte 1) Adjacent Channel Power Ratio Location (0 = current measured value, 1-200 = value in stored trace) Site Master Returns: 29 bytes 1) ACPR On/Off 2-5) Main Channel Center Frequency 6-9) Main Channel Bandwidth 10-13) Adjacent Channel Bandwidth 14-17) Channel Spacing 18-21) Main Channel Power (= (power in dBm * 1000) + 270000) 22-25) Lower Adjacent Channel Power (= (power in dBm * 1000) + 270000) 26-29) Upper Adjacent Channel Power (= (power in dBm * 1000) + 270000) Read Signal Standard Name – Control Byte #89 (59h) Description: Returns the name corresponding to the desired signal standard index as an ASCII string in English. Bytes to Follow: 3 bytes 1) Mode (00h = VNA, 01h = SPA/Transmission Mode (Option 21)) 2) Signal Standard Index (higher byte) 3) Signal Standard Index (lower byte) Site Master Returns: 2 bytes + number of bytes in string (or 1 byte on error) 1) S...
Other models in this manual:Network Equipment - Site Master S331D (566.07 kb)