Remove the clip and the stop ring from the stem of the thermostatic mixer. Turn the water on to the handshower. Turn the temperature control stem until the output water is the desired maximum high temperature -- usually 110o*. Turn the water off. Replace the stop ring so that the tooth is against the high temperature limit stop. Replace the clip. Justify the handle. *Please know and follow all applicable local plumbing codes when setting the high temperature limit stop. User Instructions Using t
. 17 For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber. Please read over these instructions thoroughly before beginning installation. Make sure that you have all tools and supplies needed to complete the installation. This product is listed by IAPMO and is approved for use in Massachusetts. • • • Protection against backflow provided by check valve in the handshower outlet. The high temperature limit stop on the thermostatic mixing valve may be
Poussez le levier de fonctions jusqu’a ce que vous obteniez le mode de jet voulu. pour les jets muraux uniquement. levier de fonctions 8 29 Nettoyage La douche a main Raindance Air 3-jet comprend le systeme nettoyant Quick Clean™ . Si vous remarquez que les canaux de jet sont entartres, ouvrez l’eau a faible debit et frottez les canaux a l’aide d’une eponge ou avec un doigt pour en deloger les depots. En cas d’entartrage de la face des jets, versez environ 2 cm (. po) d’un detartrant commercial
The diagram shows both possible positions for the installation. Wall-to-Wall Installation Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4 5 6 7 8 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 9 10 11 12 2 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill in
Damage caused by improper treatment is not covered under the warranty. Recommandations pour le nettoyage des produits Hansgrohe Les robinetteries modernes de lavabo, de cuisine et de douche utilisent des materiaux tres differents pour repondre aux besoins du marche en termes de conception et de fonctionnalite..............e.....................e.................... ...........e.....................e....................Certaines regles de base doivent etre respectees lors du nettoyage de ces prod
In Massachusetts, the water heater may be set no higher than 112oF. Installation Install the hot and cold valves Install the mounting nut, metal washer and the fiber washer on the valve. Insert the valve through the hole in the deck. The hot valve is marked with a red dot. Install the stop ring on the valve. Thread the mounting plate on the valve until the stop ring stops it at the proper height. Rest the valve on the mounting surface. Turn the valves so that the outlets point toward the center.
Ohen connecting pipework avoid using tight 90° elbows. Swept or formed bends will give the best performance. IMpoRTANT: The water circuit should be installed such that the flow is not significantly affected by other taps and appliances being operated elsewhere on the premises. Water pressure must not fall below the specification of the valve. The hot water pipe entry must be on the left-hand side. This mixer valve also includes a wall bracket which allows the installer to mount the shower int
C 1 SILICONE TEFLON ? SILICONE TEFLON For easy installation of your faucet you will need: • To READ ALL the instructions completely before beginning. • To READ ALL warnings, care, and maintenance information. • To purchase the correct water supply hook-up. 11/1/08 ® U P C TABLE OF CONTENTS: Warranty-------------------------------------------------------------Page 2 Installation Instructions -----------------------------------------------Pages 3 -8 Maintenance ------------------------------------
Important:This flushes away any debris that could cause damage to internal parts. Check all connections at arrows for leaks.Re-tighten if necessary, but do not overtighten. Flush the System and Check for Leaks 8 11/8" (3.18mm) 511/8" (3.18mm) 5 2476 Maintenance If faucet leaks from under handle: Remove handle and ensure cap (1) is tight. If leak persists–SHUT OFF WATER SUPPLIES. Replace Ball Assembly (2)–Repair Kit RP70 and Cam & Packing (3)–Repair Kit RP61. If faucet leaks from spout outlet: SH
For models with spray, go RP30394. to Step 2. 3 211233Mount the spray support assembly (1) in far right hole in sink.Hand tighten nut.Insert spray hose (2) down through support assembly and up through center For models with spray and spray support. 2Sprayer Installationhole on sink.Snap quick connect spray hose (2) onto spray hose nipple (3).Pull down moderately to ensure connection has been made.Go on to Step 2.22211233Mount the spray support assembly (1) in far right hole in sink.Hand tighten