|
manual abstract
Sit it in the sink outlet. From below, install the black mack gasket, white friction ring, and retainer nut to the flange. Do not tighten the nut against the bottom of the sink at this time. Thread the tee and tailpiece to the flange. The pivot must face the faucet. If necessary, turn the drain assembly. Tighten the retainer nut. Sit the plunger assembly in the drain. Install the horizontal rod through the pivot ball seals and into the tee so that the end goes through the loop in the bottom of the height adjuster. The two pivot ball seals should surround the pivot ball. Slide the link over end of pull rod. Tighten screw. Slide one end of spring clip over end of horizontal rod. Slide link over end of horizontal rod. Test motion of drain plunger. Reposition link as necessary. There are multiple holes in the link -- the horizontal rod may go through any of the holes. When satisfied with the action of the drain, slide the other end of the spring clip over the end of the horizontal rod. plunger flange tailpiece sealing gasket mack gasket friction ring retainer nut tee pivot horizontal rod pivot ball pivot ball seals spring clip link nut English Reset the High Temperature Limit Stop (optional) Use a 4 mm Allen wrench to push the screw cover into the handle Use the 4mm Allen wrench to loosen the handle screw 4 complete revolutions. Remove the handle. Remove the nut cover. Remove the handle screw from the stem of the cartridge. Remove the high temperature limit stop. Replace the high temperature limit stop so that the pin on the cartridge is in the desired slot on the limit stop. Note: the temperatures given in the diagram assume a water heater temperature of 140° F, a cold water temperature of 50° F and a water pressure of 45 PSI. Replace the nut cover. Replace the handle screw. Use the Allen wrench to turn the screw 4 revolutions. Replace the handle. Finish tightening the handle screw. Turn on the water and test the faucet. Francais Mitigeurs de lavabo Solaris E 06631XX0 Stratos E 06575XX0 Metro E 06571XX0 Donnees techniques Pression d’eau recommandee 22 -72 psi Temperature recommandee pour l’eau chaude 120° – 140°F * Dimension du trou dans la surface de montage 1 1/4 po Epaisseur maximale de la surface de montage 1 5/8 po Debit 2,2 gpm max. Accredite par IAPMO * Vous devez connaitre et respecter tous les codes de plomberie locaux applicables pour le reglage de la temperature du chauffe-eau. Dans le Massachusetts, la temperature d’un chauffe-eau ne doit pas exceder 112°F. A prendre en consideration pour l’installation Les tuyaux d’arrivee flexibles requierent des butees d’arret avec des raccords a compression de 3/8 po (non compris). Le robinet comprend la butee limite d’eau chaude en position maximum. Ce reglage peut etre modifie si desire. Pour obtenir les meilleurs resultats, Hansgrohe recommande de confier l’installation a un plombier professionnel certifie. Stratos E 06575XX0 Metro E 06571XX0 Solaris E 06631XX0 Installation Placez le robinet et le...
Other models in this manual:Plumbing Product - Metro E 06571XX0 (1007.6 kb)
Plumbing Product - Metro E 06571XX0 (1007.6 kb)
Plumbing Product - Metro E 06571XX0 (1007.6 kb)