|
manual abstract
13-1/2 inch x 11 inch Intake ................................................. 2 inch Performance Discharge............................................ 2 inch NPT female, 3 inch NPT male Cut-in level (factory set)....................18 inch Cut-out level (factory set) ................. 10 inch GALLONS PER hOuR At tOtAL hEAD IN fEEt Model 10 15 200 SEL40 3700 1350 Differential......................................... 8 inch SEL50 6420 4200 1500 Switch.................................................90. wide angle mechanical tether switch Power cord.........................................16 gauge 3 conductor w/plug REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2009 Wayne Water Systems For parts, product & service information 330002-001 3/09 visit Operating Instructions and Parts Manual General Safety Information 6. Check hoses for weak and worn condition before each use, making (Continued) certain that all connections are GENERAL SAfEty secure. 1. Know the pump application, 7. Periodically inspect the pump and limitations, and potential hazards. system components. Perform routine Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Personal injury and/or property damage could result. 2. Make certain that the power source (electric motor) conforms to the requirements of the equipment. Disconnect power before servicing. If the power disconnect is out of sight, lock in the open position and tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock! 3. Release all pressure within the system before servicing any component. 4. Drain all liquids from the system before servicing. 5. Secure the discharge line before starting the pump. An unsecured maintenance as required (See Maintenance Section). 8. Provide a means of pressure relief for pumps whose discharge line can be shut-off or obstructed. 9. Personal Safety: a. Wear safety glasses at all times when working with pumps. b. Keep work area clean, uncluttered and properly lighted; replace all unused tools and equipment. c. Keep visitors a safe distance from the work area. Make workshop child-proof with padlocks, master switches, and by removing starter keys. 10. When wiring an electrically driven pump such as this, follow all electrical and safety codes, as well as the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). Risk of electric shock! Never connect the green (or green and yellow) wire to a live terminal! discharge line will whip, possibly causing personal injury and/or property damage. 11. This equipment is only for use on 120 volt (single-phase) and is equipped with an approved 3-conductor cord and 3-prong, grounding- type plug as shown in Figure 1. Grounding blade figure 1 To reduce the risk of electric shock, the motor must be securely and adequately grounded. This can be accomplished by the following: 1. Inserting plug directly into a properly installed and grounded 3-prong, grounding-type receptacle (as shown in Figure 1). 2. Permanently wiring the unit with a grounded, metal raceway system. 3. Other suitable means. Where a 2-prong wall receptacle is encountered, it must be replaced with a properly grounded 3-prong receptacle installed in accordance with the NEC and local codes and ordinances. 12. All wiring should be performed by a qualified electrician. 13. It is strongly recommended that this unit is plugged into a Ground Fault Circuit Interrupter (GFCI). Consult a local electrician for installation and availability. figure 2 - typical Installation Upper level drainage Float switch 2 inch Check Valve 45. Elbow Washer Dryer Floor drain Washer drain Flange Cleanout Laundry tubs Lavatory Shower Toilet Vent pipe Vent pipe Sewage pump passes 2 inch dia. solids Three prong grounded outlet equipped with a ground fault interruptor 2 inch Gate Valve 2 inch Discharge pipe * * Main waste line to sewer or septic tank 2 Models SEL40 and SEL50 General Safety Information (Continued) The pump motor is equipped with automatic resetting thermal protector and may restart unexpectedly. Protector tripping is an indication of motor overloading as a result of operating the pump at low heads (low discharge restriction), excessively high or low voltage, inadequate wiring, incorrect motor conditions, or a defective motor or pump. 14. This pump is designed to transfer water in cycles. Using this pump in a continuous duty application by manipulating the switch to stay on, will affect the performance and the life of the product. 15. Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Replace or repair damaged or worn cords immediately. Use wire of adequate size to minimize voltage drop at the motor. 16. Do not handle a pump or pump mo...
Other models in this manual:Plumbing Product - 330002-001 (654.51 kb)
Plumbing Product - SEL40 (654.51 kb)