|
manual abstract
724-746-5500 | blackbox.com 2-1 Auto-Sync Time Clock Figure 2-2. Auto-Sync Time Clock Cover Removal. 2.4. Unpacking the Clock After removing the upper cover, lift up the Printer Block (A) and remove the Packaging Spacer (B). Figure 2-3. Auto-Sync Time Clock Packaging. NOTE: The serial number can be found on the bottom of your clock. 2.5. Installing the (ASTCBK) Optional Full Power Reserve (FPR) 1. Disconnect the clock AC adapter from the power outlet. NOTE: Failure to do so could result in a hazardous shock. 2. Insert the key, turn the key clockwise, and remove the upper cover of the Auto- Sync Clock (see Figure 2-2). 3. Remove one small Phillips head retaining screw from the right and left front sides of the top plate (see Figure 2-4). 2-2 724-746-5500 | blackbox.com Chapter 2: Installation Figure 2-4. Top Plate Removal. 4. Disconnect the Ethernet cable at the RJ-45 network connector (see Figure 2-4). You DO NOT have to remove the cable from under the wall mounting plate on the back – just disconnect it at the RJ-45 connector. 5. Lift up the top plate by pulling upwards and towards the back of the clock to remove it. Temporarily set aside. Note the alignment of the top plate during removal – especially the front and rear tabs (see figure to the right). 6. Carefully lift the front PCB up and out of its retaining slot (see Figure 2-6). This is the PCB with the coin battery on it. Just lift the PCB up enough to provide adequate clearance for the FPR mounting bracket to be inserted into its side retaining slots on the right and left sides of the main clock frame (see Figure 2-6). 7. Carefully insert the FPR mounting bracket with the FPR battery pack (see Figure 2-5). It will fit only one way as it must slip over the rectangular shaped network connector (see Figure 2-7). 724-746-5500 | blackbox.com 2-3 Auto-Sync Time Clock Figure 2-5. FPR & Mounting Bracket. 8. After the FPR mounting bracket is in its proper position, return the front PCB to its original position seated in its retaining slot. In this position the top rear of the PCB will fit close alongside the FPR mounting bracket (see Figure 2-6). Figure 2-6. Front PCB & FPR Mounting Bracket in Position. 9. Install the two plastic rivets (1 per each side) as illustrated in Figure 2-7 through the side of the clock frame into the proper locating hole in the FPR mounting bracket (see Figure 2-5). 2-4 724-746-5500 | blackbox.com Chapter 2: Installation Insert Plastic Rivet Insert Plastic Rivet Figure 2-7. Auto-Sync Time Clock Rear View. 10. With the FPR battery pack in the holder alongside the network RJ-45 connector, plug in the FPR battery cable (the connector with the black and red wires) into the open brown connector (see Figure 2-7) located just under the battery pack on the PCB at CN4. Figure 2-8. Rear View Showing Cable/Connector Location. 724-746-5500 | blackbox.com 2-5 Auto-Sync Time Clock NOTE: For units with the FPR option, disconnect the FPR battery pack cable connector if the Auto-Sync Time Clock will not be plugged into AC power for an extended amount of time. Leaving the battery pack connected without charging for a long time could promote battery harm and damage to the clock. 11. Carefully reinstall the top plate by first inserting the rear tabs into the appropriate rear notches, making sure the rear centering tab is in its notch. Then push the plate forward (see right-hand figure) while properly aligning the top plate sides and front. Finally push the top plate downward to lock it firmly into position with the front tabs (see Figure 2-9). Figure 2-9. Top Plate Installed. 12. Insert the Ethernet connector through the hole in the rear of the top plate into the RJ-45 network connector (previously disconnected in Step 4). 13. Insert and tighten the two (2) side retaining screws (one on right and left front sides) for the top plate (see Figure 2-9). 14. Replace the upper cover of the Auto-Sync Time Clock (see Figure 2-2). 15. Connect the clock Ethernet cable to a network connection and plug the AC power transformer into a wall socket. 2-6 724-746-5500 | blackbox.com Chapter 2: Installation NOTE: After installing the FPR and connecting the unit to AC power for the first time, allow it to charge the battery pack for 24 hours before printing. Failure to do so may result in reduced battery life. When using the optional FPR - keep the clock plugged into an AC power source during normal operation to maintain an adequate charge. The power reserve battery is designed to be used only during limited power outages, not as a power source during normal operation. The FPR can maintain normal operation for up to 6 hours or 400 print stamps. 2.6. Installing the (ASTCPOEK) Optional PoE with FPR If your Auto-Sync Time Clock came equipped with the PoE option skip to Step 17. 1. Disconnect the clock AC adapter from power outlet. NOTE: Failure to do so could result in a hazardous shock. 2. Insert the key, turn the key clockwise, and remove the upper cover of the Auto- Syn...
Other models in this manual:Time Clocks - ASTC3000POE (2.78 mb)
Time Clocks - ASTCBK (2.78 mb)
Time Clocks - ASTCKEY (2.78 mb)
Time Clocks - ASTCPOEK (2.78 mb)