User manual Ericsson, model LBI-38823C

Manafacture: Ericsson
File size: 2.45 mb
File name: lbi-38823c.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


Messages cannot be received when the PTT bar is pressed. 32 6. When the call is complete, double click the SHIFT/CLR button to exit the Special Call mode and return to the normal system/group display. Storing Individual And Interconnect Numbers 1. Press the SPC key to put the radio into Special Call mode. The SYStem field will display "SP" and the GRP (Group) field will display the last accessed call number from the preprogrammed Special Call list. The "S" and "PC" icons will also be illuminated while in the Special Call mode. 2. Enter the ID number or telephone number of the radio to be stored. The first digit entered will cause System display and the 10’s digit in the Group field to blank. The last digit entered will always be displayed in the 1’s digit of the Group field. Any previously entered digits will scroll left. Only four characters will be visible at a time with the leading character scrolling off the display upon each new key entry. NOTE To recall the last individual or interconnect number entered manually from the key pad, press and hold the SHFT/CLR button and then press the RCL key. 3. Complete the entry by pressing the # key for individual numbers and the * key for telephone interconnect numbers. The # key indicates the digits entered are for an individual call and * key indicates the digits are for an interconnect call. They will not be displayed but a tone will sound. 4. Enter a digit between 0 and 9 to select a storage location. The storage location will not be displayed, but a tone will sound. There are 10 storage locations for individual numbers and 10 storage locations for interconnect numbers. 33 5. Press the STO key (shifted *) to complete the storage procedure. 6. Double click the SHIFT/CLR button to exit the Special Call mode and return to the normal System/Group display. Recalling Manually Stored Individual And Interconnect Numbers 1. Press the # key to recall the individual call list or the * key to specify the interconnect call list. The screen will blank and a tone will sound. 2. Enter the desired storage location number (0-9). 3. Press the RCL (shifted #) key and the radio will switch to the Special Call mode. If the number is from the individual call list the ID number will be displayed. If the number is from the interconnect call list, the last four digits of the telephone number will be displayed. If the memory location is blank the radio will sound a low pitch tone after the RCL is pressed. 4. Individual - Once the desired individual call number is displayed in the GRP (Group) field, press and hold the PTT to initiate the call. The radio performs the necessary signalling required to obtain a working channel. Interconnect - Once the desired interconnect special call number is displayed in the GRP (Group) field, press and release the PTT to initiate the call. The radio performs the necessary signalling required to obtain a working channel. 5. Individual - When the signalling is successfully completed the "TX" and "BSY" flags turn on and the Call Originate tone sounds. Speak directly into the microphone. Release the PTT bar as soon as you stop talking and wait for a reply. 34 Interconnect - When the signalling is successfully completed the "BSY" flag turns on and the proper DTMF tones will be sent and heard at the speaker. When someone answers, press the PTT bar and speak directly into the microphone. Release thePTT bar as soon as you stop talking. Messages cannot be received when the PTT bar is pressed. If the signalling is unsuccessful, the radio will remain in the the Special Call Mode and sound the appropriate alert tone(s). 6. When the call is complete, double click the SHIFT/CLR button to exit the Special Call mode and return to the normal System/Group display. Figure 10 - EDACS Special Call Flowchart 35 SCAN OPERATION Enable/Disable SCAN To enable Group scanning, press and release the SCAN key. The "SCN" icon will illuminate to indicate scan is active. When scan is on, press and release the SCAN key to disable scan operation. The "SCN" icon will be extinguished when scan is turned off. Add/Delete Groups Groups can be added or deleted from the scan list as necessary. To add Groups to the scan list: 1. Select the desired Group to be added. If the current group is already included in the scan list, the "S" icon will be illuminated. 2. To add the group to the scan list, press the SHIFT/CLR key and then press the SCAN key. The "S" icon will illuminate and the group will be included. NOTE Scan must be disabled to add a Group to the scan list. To delete Groups from the scan list: 1. Select the desired Group to be deleted. If the current group is already included in the scan list, the "S" icon will be illuminated. 2. To delete the group from the scan list, press the SHIFT/CLR button and then press the SCAN key. The "S" icon will turn off and the group will be removed from the scan list. Wide Area And Priority System Scanning (Optional) Dual Format PCSO radios operating within ...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category