Login:
Votes - 1, Average rating: 4 ( )

User manual Oregon Scientific, model BARM699A

Manafacture: Oregon Scientific
File size: 1.41 mb
File name: 9934f39b-ef67-42af-91cd-500d4d454f77.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Press ALARM to view the alarm. will show on the display. 2. Press and hold ALARM for 2 seconds. 3. Press TUNING / SET / to change the hour, minute, beep or radio alarm. If you select the radio alarm, press AM / FM and STATION to select the band and station respectively. 4. Press ALARM to confirm. To activate or deactivate the alarm: Press ALARM when in the alarm display. or appears when the alarm is set. To silence the alarm: • Press SNOOZE to silence it for 8 minutes. OR • Press any key except SNOOZE to turn the alarm off and activate it again after 24 hours. NOTE or flashes when snooze is activated. WEATHER FORECAST This product forecasts the weather for the next 12 to 24 hours within a 19-31 mile (30-50 km) radius, with 70 to 75 percent accuracy. SUNNY PARTLY CLOUDY CLOUDY RAINY TEMPERATURE To change the temperature measurement unit: Press °C / °F on the bottom of the unit. To view outdoor sensor(s) temperature readings: Press CHANNEL. • shows which remote sensor’s data you are viewing. • is permanently displayed in the indoor temperature area. To auto-scan between sensors: Press and hold CHANNEL for 2 seconds. Each sensor’s data is displayed for 3 seconds. To end auto-scan: Press CHANNEL or MEMORY. To toggle between current, minimum and maximum records for the selected sensor: Press MEMORY repeatedly. To clear the records: Select the channel to clear the memory, then press and hold MEMORY for 2 seconds. BARM699A_EN_R5.indd 1 2/17/06 2:04:50 PM NOTE The indoor memory record will be cleared simultaneously. ICE WARNING If the channel 1 sensor falls between 3°C to -2°C (37°F to 28°F), will flash to warn you that the temperature is approaching freezing. NOTE The alarm will automatically stop if the temperature goes outside the ice-warning range. RADIO You can save up to 16 radio stations (8 for AM and 8 for FM). To turn the radio ON / OFF: Press RADIO. To save a station: 1. Press RADIO to turn the radio ON. 2. Press AM / FM to select radio frequency. 3. Press TUNNING / SET / to manually fine tune the frequency or press and hold TUNNING / SET / to activate auto-search. 4. Press and hold STATION to save the station. SLEEP TIMER To turn the sleep timer ON: 1. Press SLEEP once to activate the last setting used. 2. Press SLEEP to set radio sleep timer duration (120, 90, 60, 30, 15 or 0 minutes). Select “0” to disable the sleep timer. 3. Press VOLUME / to change the volume. NOTE “SLEEP” flashes when the sleep timer is activated. BACKLIGHT Press any key to activate the backlight for 1 minute. RESET Press RESET to return the main unit to the default settings. Remove and then re-insert the batteries to reset the sensor. PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions: • Do not use a damp cloth to clean the surface of the light touch key, If it is necessary to use a damp cloth to clean the unit, turn the power off before cleaning. • Placement of this product on wood surfaces with certain types of finishes, such as clear varnish, may result in damage to the finish. Consult the furniture manufacturer’s care instructions for direction as to the types of wood surface. Oregon Scientific shall not be responsible for any damage to wood surfaces from contact with this product. • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. • Do not clean the unit with abrasive or corrosive materials. • Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts. • Do not tamper with the unit’s internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts. • Only use fresh batteries as specified in the user’s instructions. Do not mix new and old batteries. • Do not use rechargeable batteries. • Remove batteries when storing the product for a long time. • Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. • Due to printing limitations, the displays shown in this manual may differ from the actual display. • The contents of this manual may not be reproduced without the permission of the manufacturer. NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice. SPECIFICATIONS TYPE DESCRIPTION Main unit Dimensions 163 x 65.4 x 96 mm (L x W x D) (6.4 x 2.6 x 3.8 inches) Weight 300g (10.6 ounces) Temperature unit – °C / °F Indoor range -5°C to 50°C (23°F to 122°F) Outdoor range -30°C to 60°C (-22°F to 140°F) Resolution 0.17°C (0.2°F) Radio clock Synchronization Auto or disabled Clock display HH:MM Hour format 12hr AM/PM or 24hr Calendar DD/MM or MM/DD Weekday in 5 (E, G, F, I, S) languages Alarm 2-minute beep or radio alarm with 8-minute snooze PLL Radio ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category