Manafacture: Graco
File size: 928.64 kb
File name:
|
manual abstract
1). Figure 1 fig. 1 Sensor Pad Sensor Pad CORRECT INCORRECT PLACEMENT OF SENSOR PAD CORD CORRECT Sensor Pad Centered Turquoise Side Up INCORRECT Sensor Pad Off Center INCORRECT Sensor Pad Turquoise Side Down POSITION OF SENSOR PAD UNDER MATTRESS (Top Down View of Crib) fig. 2 IMPORTANT: Only use the AC adapters included with your monitor. Do not use these adapters with any other equipment. Movement Sensitivity Control. The movement sensitivity control is on the back of the Nursery Unit. The level has been preset to 2.5 (see fig. 3). Do not adjust this unless you receive false alarms. Refer to the Movement Sensitivity Adjustment section on Pg. 11 for more information. It is extremely Movement Sensitivity Control. important to follow our instructions for setting the sensitivity level. fig. 3 Now plug the Sensor Pad cord into the jack on the back of the Nursery Unit marked “Sensor Pad.” Turn the Nursery Unit on using the switch on the left. The green Power Indicator will light up. 8 Activating Units Always test your monitor before using it the first time and then on a periodic basis. Before testing your monitor, complete the setup process as described above. On the back of the Nursery Unit select one of the following three functions: • Sound & Movement: You will be able to hear your baby's sounds, see sound lights, and hear a “Tic” sound with every movement your baby makes. If no movement is detected, the “Tic” will stop and after 20 seconds the alarm will sound. • Tic Off: In this mode you will not hear a “Tic” with every movement. You will still hear your baby's sounds and see sound lights, and your baby's movement is still being detected. The default setting is “Tic Off.” • Sound Only: The Movement Sensor is disabled but you will still be able to hear your baby's sounds and see sound lights. Your Angelcare® works like a regular sound monitor when set to “Sound Only.” Sound &Movement SoundOnly Tic Off Sensor Pad Sensitivity NurseryUnit Model #AC201 1 Sound Only Select "Sound Only" as shown. Micro. Tic / Alarm Low Batt. / Power A B 2 3 Turn the Parents' Unit ON by selecting either channel "A" or "B". Make sure it is set to the same channel as the Nursery Unit. The green power indicator light will light up. Choose the channel that gives you the best reception. Adjust the volume to the desired level as shown. 9 Sound & Movement NOTE: Make Sure your Sensor Pad is set up before proceeding with this section. If you haven't set up your Sensor Pad please go to Pg.8 for instructions on how to properly set up the Sensor Pad. Sound &Movement SoundOnly Tic Off Sensor Pad Sensitivity NurseryUnit Model #AC201 1 • Sound & Movement: You will be able to hear your baby's sounds, see sound lights, and hear a “Tic” sound with every movement your baby makes. If no movement is detected, the “Tic” will stop and after 20 seconds the alarm will sound. Switch the Nursery Unit to the "Sound & Movement" function. Turn the Parents' Unit ON by selecting either channel "A" or "B". Make sure it is set to the same channel as the Nursery Unit. The Movement Indicator Light on the Nursery Unit will flash red, green, and then emit a single "Tic" sound. Gently pat your hand on the mattress. The green Movement Indicator Light will continue to flash with every movement. The Nursery Unit will also tick with every movement. Remove your hand from the mattress. Due to no movement, the ticking will stop, the Movement Indicator Light will stop flashing, and a pre-alarm beep will sound after 15 seconds. Five seconds later the alarm will sound and the red Alarm Indicator Light will flash continuously. Tic Off You can also test for movement with the Nursery Unit set to the “Tic Off” position. In this case, you will not hear a constant ticking when you touch the mattress. When you remove your hand from the mattress the Movement Indicator Light will stop flashing, a pre-alarm beep will sound after 15 seconds, and five seconds later the alarm will sound and the red Alarm Indicator Light will flash continuously. To turn off the alarm, turn the Nursery Unit off or pat your hand lightly on the mattress so the Sensor Pad will redetect movement. The red Alarm Indicator Light on the Nursery Unit will continue to flash for one minute and it will then revert to green. If the alarm does not sound when you are not touching the mattress, the Sensor Pad may be detecting a continuous vibration from another source from inside and/or outside your baby's room. Common sources of this interference are crib mobiles, fans, washing machines, or even loud music. Therefore, it is very important to make sure all vibration sources are eliminated before using the monitor. Place the crib near a solid supporting wall and away from strong air currents. Do not use crib mobiles or accessories that may cause vibrations. Avoid contact with the crib when the monitor is in use. If you find the alarm will still not sound when you are not touching the mattress or crib, the monitor is on, and you...
Other models in this manual:Baby Monitor - Angelcare 1750296 (928.64 kb)
Baby Monitor - Angelcare AC2012P (928.64 kb)