Login:
Votes - 1, Average rating: 4 ( )

User manual Euro-Pro, model S3306HB

Manafacture: Euro-Pro
File size: 298.55 kb
File name: S3306HB-S3306HC-S3306HG_REV_0406.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Caution: Always unplug before filling. ALLOW UNIT TO COOL FOR FIFTEEN (15) MINUTES BEFORE REFILLING.IMPORTANT: Do NOTadd cleaning solutions, scented perfumes, oils or any other chemicals to the boiler in this appliance. Use tap water or distilled/ purified water if the tap water in your area is very hard.Filling or Refilling Your Steam Cleaner With WaterImportant: Always insure that the unit is “UNPLUGGED” from the wall receptacle prior to initial filling or re-filling the water tank and has been allowed to cool for 15 minutes. Never attempt to fill this unit under awater tap, always use the filling funnelprovided. 1. Remove the plug from the electrical outlet and allow the steam cleaner to cool for fifteen (15) minutes. 2. Press the steam trigger on the hand grip to vent any residual steam pressure that is in the boiler. 3. Place the unit on a flat, stable surface. Push down firmly on the safety cap and slowly turn the safety cap counter clockwise until it is removed. 4. Place the funnel in the tank opening. (Fig. 1) Fill with a maximum of one filling flask or 2 cups (500 ml) of water. Do Not Overfill. Turn the safety cap clockwise to replace. Note: To remove or replace the safety cap, push down on it firmly and rotate it clockwise to tighten or counter clock- wise to loosen. If not depressed the cap will rotate freely without advancing. Note: Filling the unit with hot water will shorten the heat up time. Warning: Extreme care should be taken when refilling the unit. Allow unit to cool for 15minutes and vent any residual steam pressure (see Step #2) from the boiler before refilling. When refilling the steam cleaner while the boiler is still hot, there is a risk that water will squirt back during filling and cause scalding. Use caution when opening the Safety Cap as cap may become hot during use and escaping steam can cause scalding. 5. Connect desired attachments onto the flexible steam hose. 6. Plug the unit into a standard ( 120 volt, grounded) wall receptacle and switch the On/Off switch to the “On” position. Allow approximately 4-6 minutes for vapor to reach its working temperature and pressure. When the unit is ready for use, the steam ready light will turn “On” . Always point nozzle outlet in a safe direction. At the start, some water will come out from the nozzle. This is normal. Note: When the steam cleaner has run out of water, steam output will cease. 7. When finished using the unit, turn it “Off” and unplug it from the electrical outlet.Warning: This appliance is under pressure. After every use, press steam trigger button until all pressure has been released before removing safety cap. Allow unit to cool for fifteen (15) minutes refilling. Fig. 1Important: When using the steam cleaner with the shoulder strap, avoid rocking or tilting the unit excessively as this may cause water to enter the hose and be discharged along with the steam. OPERATING INSTRUCTIONSAttaching the Shoulder StrapFig. 8Fig. 11Fig. 10Using the detachable shoulder strap allows for greater freedom of movement when both hands are needed for various cleaning tasks. To attach the shoulder strap to the steam cleaner, simply snap the shoulder strap hooks onto the connecting rings on the unit body. (Fig. 9, 10 & 11) ConnectingpointsConnectingpointsFig. 9 Note: Fit the steam pocket frame with the angle adapter onto the extension tube. Step 2. If the angle adapter is not attached to the steam pocket frame, attach as follows: Hold the steam pocket frame in one hand and the angle adapter in the other. Insert the angle adapter steam into the opening of the steam pocket frame as shown in Fig. 5. Note that the flat on the nozzle must face toward the side of the frame with the brass pin. Once inserted, rotate it 90°. Step 3. Insert the electrical power cord into the outlet. Heating time is approximately 4-6 minutes with cold water. Filling the steam generator with hot water will shorten the heat up time. Using Your Steam Cleaner with Steam PocketStep 1. Connect the steam pocket accessory to the steam handle with two extension tubes. To attach the extension tubes one onto the other or onto the hand grip, press the locking button ensuring that it fits into the hole (Fig. 3., Fig. 4) and press the two sections together. To disconnect, repeat the operation by pressing the locking button and pulling the two sections apart. Attaching the Steam Pocket Towel to the Frame1. Slide the steam pocket towel over the steam pocket frame. (Fig. 6) 2. Bring the towel all the way to the top of the steam pocket frame. (Fig. 7) 3. Bring the hook and latch strips that are on the back side of the steam pocket towel over the steam pocket frame and attach to the inside of the front side of the steam pocket towel. (Fig. 8) Note: If replacing the steam pockettowel, make sure that the steam pocket frame has been allowed to cool before removing or attaching a new steam pocket towel. Warning: Always insure the unit is “ UNPLUGGED” from the wall receptacle prior to attach...

Other models in this manual:
Vacuum Cleaners - S3306HC (298.55 kb)
Vacuum Cleaners - S3306HG (298.55 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category