Login:
Votes - 0, Average rating: 0 ( )

User manual HP, model HP 3PAR InForm Software

Manafacture: HP
File size: 96.29 kb
File name:
Language of manual:ennn
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


These release notes describe the modifications and known issues for Patch 20 (P20). The application
of this patch is intended for HP 3PAR InForm OS 2.3.1.330 (MU4).
1.1 Supported Platforms
The HP 3PAR Configuration Matrix for InForm OS 2.3.1 contains information about supported hardware
and software platforms.
To obtain a copy of this documentation, go to the Single Point of Connectivity Knowledge for HP
Storage Products (SPOCK) Web site at http://spock.corp.hp.com/index.aspx.
1.2 Verifying the Patch Installation
The installation of Patch 20 can be verified from an Interactive CLI session through the SPMAINT main
menu. Issue the CLI command showversion -a -b to see Patch 20 listed.
cli% showversion -a -b
Release version 2.3.1.330 (MU4)
Patches: P20
Component Name Version
CLI Server 2.3.1.330 (MU4)
CLI Client 2.3.1.330 (MU4)
System Manager 2.3.1.330 (MU4)
...
1.3 Components
Component
Version
OS
2.3.1.330 (MU4)
NOTE:
Applying this patch to the InForm OS may cause a restart of the affected OS components.
With these restarts, expected behaviors such as events and alerts may generate. The system will
continue to serve data but existing CLI or IMC sessions may be interrupted.
1.4 Modifications to the InForm OS
The following items have been addressed in this release.
Bug ID
Component
Version
59488
Update ViperC firmware to
If an online firmware upgrade is performed, the recommended defect settings
3P02 and VXC2 so SMART is to the mode page 1C will be lost. To reinstate the settings, activate the
enabled by default
disk-ready process by issuing admitpd again after dismisspd
first or servicemag start -log -pdid and then
servicemag resume.
61808
Cage failed and became
Corrects an error in serial port where characters were looped back to the
inaccessible after reset.
serial port which sometimes could cause timeout results a cage resets and
becomes inaccessible.
The fix also contains additional checks to prevent cage from being
inaccessible.
62564
Do not use the SCSI-2
showrsv and the IMC retrieving reservation info will no longer cause a long
reservation lock when
block of being able to run other commands.
servicing the
MCLP_SCSI2_SHOW mcall.
1.1 Supported Platforms
3


...

Other models in this manual:
Media Storage - HP 3PAR Operating System Software Suite (96.29 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category