User manual Toshiba, model Conference Room Projectors TDP-T95U

Manafacture: Toshiba
File size: 3.5 mb
File name:
Language of manual:
Free link for this manual available at the bottom of the page



manual abstract


• In the event of lamp burst, unplug the product from the wall outlet, leave and completely ventilate the room. Then, thoroughly clean the area around the projector and discard any edible items placed in that area. • When the lamp bursts, consult a doctor if glass dust or mercury gas gets into your eyes or you breathe it. Maintenance 42 43 45 Maintenance 44 1 Unplug power cord. 2 Wait until lamp is sufficiently cooled. Wait for at least 1 hour. 3 Remove the lamp cover. Loosen the two screws, raise the lamp cover with your fingers as shown to remove the lamp cover. Use care to avoid any damage to nails and/or tip of your finger(s). If you have any difficulty in removal, you can use a screwdriver or any other smaller tool for your convenience. Lamp cover 2 1 1 2 3 4 Pull out the lamp. 4 Loosen the three lamp locking screws, pull up the handle, and remove the lamp. 5 Mount the new lamp. Align the orientation, press down the new lamp until the bottom is reached, and lock in place using the three lamp locking screws. 6 Replace the lamp cover. Align the cover, and press it in, then tighten the screws loosened in step 3 until the lamp cover is no longer loose. 7 Reset the lamp timer. See the lamp’s manual for instructions on resetting the lamp timer. Notes and Precautions • The Lamp time item in the Status display menu indicates the time of lamp use (as a rough guide). p.42 • It is recommended that the lamp be replaced after 2,000 hours of use. When [Lamp time] reaches 2,000 hours, the icon and a message will appear. (After 2,000 hours, they will appear when the power is on at the first time every 100 hours.) This display disappears when you press the button. • Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the projector may fail to be powered on or the lamp may fail to come on. • Always replace the lamp with a new one. • The lamp is made out of glass. Do not touch the glass surface with your bare hands, bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.) Used Lamps This projector’s lamps contain trace amounts of environmentally harmful inorganic mercury. Be careful not to break used lamps, and dispose of them in accordance with local regulations. A lamp is consumable supplies. If used for extended periods, images will appear dark, and the lamp could burn out. This is characteristic of a lamp, and is not malfunction. (The lifetime of the lamp depends on condition of use.) If this happens, replace it with a new one. WARNING • If the projector is mounted on the ceiling, it is recommended to use your Toshiba dealership when the lamp has to be exchanged. Uncovering the lamp while the projector is mounted on a ceiling may lead to a danger of damage from falling pieces of glass if the lamp is broken. Besides, working at high elevations can al...

Other models in this manual:
Projectors - Conference Room Projectors TDP-T100U (3.5 mb)
Projectors - TDP-T100U (3.5 mb)
Projectors - TDP-T95U (3.5 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category