This is a rapid beeping of the audible alarm. Check your tubing or accessories for blocked or kinked tubing or a defective humidifier bottle. After rated flow is restored, more than 0.5 L/min for Platinum 5 (1 L/min for Platinum 10), the LOW FLOW audible alarm will go off. NOTE: The use of some accessories such as the pediatric flowstand and the HomeFill compressor will deactivate the Low Flow Alarm. Flow Knob Ball FIGURE 5.6 Flowrate Platinum™ Series 20 Part No 1118353 SECTION 5—OPERATING INSTRUCTIONS Front Panel Indicators - Units with SensO2 NOTE: For this procedure, refer to FIGURE 5.7. The SensO2 feature monitors the purity of oxygen generated by the oxygen concentrator. If purity falls below factory preset standards, indicator lights on the control panel will illuminate. . . . . . . . O2 . FIGURE 5.7 Front Panel Indicators - Units with SensO2 Initial Startup of the Concentrator NOTE: Concentrator may be used during the initial start warm.uptime (approximately 30 min.) while waiting for the O2 purity to reach maximum. LABEL SYMBOL O2 PURITY INDICATOR LIGHTS (LED) O2 SYSTEM OKAY O2 over 85% (± 2%) GREEN Indicator Light O2 Between 73% (± 3%) to 85% (±2%) YELLOW Indicator light A. YELLOW Solid B. YELLOW Flashing Sensor Failure Call a qualified technician. Have a back-up supply of oxygen ready. SYSTEM FAILURE O2 Below 73% (±3%) RED Indicator Light Continuous Audible Alarm Sieve-GARD Compressor Shutdown. Call a qualified technician. Switch to a back-up supply of oxygen immediately. Part No 1118353 21 Platinum™ Series SECTION 5—OPERATING INSTRUCTIONS Front Panel Indicators - Units without SensO2 NOTE: For this procedure, refer to FIGURE 5.8. . . . . . . FIGURE 5.8 Front Panel Indicators - Units without SensO2 Initial Startup of the Concentrator NOTE: Concentrator may be used during the initial start warm.up time (approximately 30 min). O2 purity will build to a maximum during this period. LABEL SYMBOL STATUS INDICATOR LIGHTS (LED) I/O SYSTEM OKAY GREEN Indicator Light SYSTEM FAILURE RED Indicator light Continuous Audible Alarm Sieve-GARD™Compressor Shutdown Call a qualified technician. Switch to a back-up supply of oxygen immediately. Platinum™ Series 22 Part No 1118353 SECTION 6—MAINTENANCE SECTION 6—MAINTENANCE WARNING The Invacare concentrators are specifically designed to minimize routine preventive maintenance. Only qualified personnel should perform preventive maintenance on the concentrator. Power should be disconnected before beginning preventive maintenance on the Invacare concentrator. NOTE: At a minimum, preventive maintenance MUST be performed according to the maintenance record guidelines. In places with high dust or soot levels, maintenance may need to be performed more often. Refer to Preventive Maintenance Record on page 25. Routine Maintenance NOTE: The following routine maintenance should be performed more frequently. See recommended intervals in each section and preventive maintenance record. Cleaning the Cabinet Filter CAUTION DO NOT operate the concentrator without the filter installed. NOTE: For this procedure, refer to FIGURE 6.1 on page 24. NOTE: There are two cabinet filters one located on each side of the cabinet. 1. Remove each filter and clean at least once a week depending on environmental conditions. NOTE: Environmental conditions that may require more frequent cleaning of the filters include but are not limited to: high dust, smoking, air pollutants, etc. Part No 1118353 23 Platinum™ Series SECTION 6—MAINTENANCE 2. Clean the cabinet filters with a vacuum cleaner or wash in warm soapy water and rinse thoroughly. 3. Dry the filters thoroughly before reinstallation. FIGURE 6.1 Cleaning the Cabinet Filter Cabinet Filter (located on both sides of concentrator) Cleaning the Cabinet WARNING UNPLUG the concentrator when cleaning. To avoid electrical shock, DO NOT remove cabinet. Clean the cabinet with a mild household cleaner and non.abrasive cloth or sponge. Cleaning the Humidifier NOTE: To clean the oxygen humidifier, follow the instructions provided by the manufacturer. If none are provided, follow these STEPS: 1. Clean the humidifier every day. 2. Wash it in soapy water and rinse it with a solution of ten parts water and one part vinegar. 3. Rinse thoroughly with hot water and refill with distilled water to the level shown on the humidifier. Platinum™ Series 24 Part No 1118353 SECTION 6—MAINTENANCE MODEL NO. IRC SERIAL NO. PREVENTIVE MAINTENANCE RECORDINVACARE PLATINUM OXYGEN CONCENTRATORON EACH INSPECTION Record Date of ServiceRecord Elapsed Hours On Hour MeterClean Cabinet Filter(s)Check Prescribed L/min. Flow RateEVERY 4,380 HOURS FOR IRC5LX (EVERY 2,160 HOURS FOR IRC10LX) Check Oxygen Concentration(UNITS WITHOUT SensO 2 ) EVERY 26,280 HOURS OR 3 YEARS, WHICHEVER COMES FIRST ( Check Oxygen ConcentrationUNITS WITH SensO 2 )DURING PREVENTIVE MAINTENANCE SCHEDULE, OR BETWEEN PATIENTS Clean/Replace Cabinet Filter(s)Check Outlet HEPA Filter*Check Compressor Inlet Fil...

Other models in this manual:
Home Care Products - IRC5LX (754.33 kb)
Home Care Products - IRC10LXO2 (754.33 kb)
Home Care Products - IRC5LXO2 (754.33 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category