Login:
Votes - 0, Average rating: 0 ( )

User manual Philips, model HB573/01

Manafacture: Philips
File size: 217.68 kb
File name:
Language of manual:enfrdenl
Free link for this manual available at the bottom of the page



manual abstract


If you open the appliance yourself during the guarantee period, your guarantee expires. • The HPA lamp for facial tanning (in the appliances HB 574 and HB 577) must be replaced by authorised service personnel exclusively. • First remove the mains plug from the wall socket. • For replacement of the TL tube lamps and/or cleaning the protective shields you need about half a meter of free space on both ends of the appliance. • Have at least one person helping you when removing the protective shield of the solarium. Support the protective shield all the time to prevent it from possible cracking, splitting or damage due to falling. Solarium - Remove the four plastic caps from the end cap and loosen the screws (fig. 1). - Remove the end cap (fig. 2). - Repeat this for the second end cap. - Pull the two side panels loose from the aluminium profiles (fig. 3). Prevent the protective shield from falling out. - Remove the four plastic bars from between the protective shield and the side panel (fig. 4). - With one person helping you, remove the protective shield (fig. 5). The TL tube lamps and starters are now accessible. - Rotate the lamps a quarter turn to the right or to the left. - The lamps can now easily be removed from their fittings. - The starters can be removed by turning them to the left. (On either side of the solarium you will find half the amount of the starters.) - Placing the new lamps and starters is in reversed order and direction. - Reposition the protective shield. The protective shield has a plastic ridge by which it hangs from the aluminium profile (fig. 6). Ensure to position the protective shield correctly. (Do not mix up the head end and the foot end!) - Press the strip back into the spacing of the aluminium profile (fig. 7). - Reposition the four plastic bars between the protective shield and the side panel (fig. 8). Please note that the plastic bars should be on the outside of the protective shield. Slide the plastic bars completely inwards: they should not protrude. It may be necessary to rotate the bars a little while sliding them. - To fix the end cap back to the solarium, first slide the section closest to the front side around the other parts (fig. 9) - Screw this section of the end cap hand tight to the appliance (fig. 10) - By and by, starting from this point, slide the end cap into place (fig. 11). - Tighten the screws. - Place the plastic caps back. Sun couch Remove the four plastic caps from the end cap and loosen the screws (fig. 12). - Remove the end cap (fig. 13). - Repeat this for the second end cap. - Pull to loosen the strip (side panel) from the two sides of the protective shield (fig. 14). - With one person helping you, remove the protective shield from the sun couch (fig. 15). The TL tube lamps and starters are now accessible. - Rotate the lamps a quarter turn to the right or to the left. - The lamps can now easily be removed from their fittings. - The starters can be removed by turning them to the left. (On either side of the sun couch you will find half the amount of the starters.) - Placing the new lamps and starters is in reversed order and direction. - Reposition the protective shield. Ensure to position it correctly. (Do not mix up the head end and the foot end!) - Press the strip back onto the two sides of the protective shield. - Reposition the end caps. - Tighten the screws. - Place the plastic caps back. Tip If merely one lamp needs replacement, it is advisable to remove the end caps (fig. 1, 2, 12 and 13), but to leave the protective shield in place. Then you can replace the lamp with one person helping you (fig. 16). Tube lamps and starters Types HB 573 and HB 574 12 tube lamps (type Philips "Cleo Professional" 90W-S) 12 starters (type Philips S11) Types HB 576 and HB 577 24 tube lamps (type Philips "Cleo Professional" 90W-S) 24 starters (type Philips S11) Francais Important • Nous conseillons en general de confier le remplacement des tubes fluorescents TL et des amorceurs a votre fournisseur ou a un reparateur agree par Philips. Si vous ouvrez vous-meme l’appareil pendant la periode de garantie, votre garantie expire. • La lampe HPA utilisee pour le bronzage facial (equipant les appareils HB 574 et HB 577) devra etre remplacee uniquement par une personne du service apres-vente agreee. • Retirez tout d'abord la fiche secteur de la prise murale. • Pour le remplacement des tubes TL et/ou le nettoyage du panneau protecteur, vous aurez besoin d'un espace libre d'environ 50 cm, aux deux extremites de l'appareil. • Faites en sorte d’etre aide d’au moins une personne lorsque vous retirez le panneau protecteur du solarium. Maintenez souleve le panneau protecteur le temps de l’intervention afin d’eviter qu’il ne se fende, se fissure ou se casse s’il venait a tomb...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category