Manafacture: ResMed
File size: 1.47 mb
File name: 24f9ee09-1e7e-4c98-b35e-52ae2e4e479f.pdf
Language of manual:svitenesfrdept
Free link for this manual available at the bottom of the page



manual abstract


Headgear reassembly instructions are provided here as additional information. / Hinweis: Das Kopfband muss zur Reinigung nicht auseinander genommen werden. Anweisungen zum Wiederzusammenbau des Kopfbandes wurden dieser Anleitung als zusätzliche Informationen hinzugefügt. / Remarque : il n'est pas nécessaire de démonter le harnais pour le nettoyage. Les instructions de remontage sont fournies à titre indicatif. / Nota: Non occorre smontare il copricapo prima délia pulizia. Le istruzioni per il riassemblaggio del copricapo sono fornite qui come spiegazione extra./ Nota: El arnés no necesita ser desmontado para su limpieza. Las instrucciones para el montaje del arnés se proporcionan únicamente como información adicional./ Nota: Nao necessita de desmontar o arnés antes de proceder à limpeza. As instruçôes de montagem do arnés säo oferecidas como informaçôes adicionáis. / Obs! Hättan behöver inte tas isär för rengöring. Monteringsanvisningarnaför hättan medföljer som extra information. Reassembling the Headgear / Wiederzusammenbau des Kopfbandes / Remontage du harnais / Riassemblaggio del copricapo / Montaje del arnés / Como voltar a montar o arnés / Montera hattan Back straps / Hintere Bänder / Sangles arrières / Cinghie posteriori / Cor reas posteriores / Correias traseiras / De bakre rem marna Back buclde / Hintere Schnalle / Boucle arrière / Fibbia posteriore / Presilia posterior / Fivela traseira / Spänne pä baksidan Top buckle / Obere Schnalle / Boucle supérieure / Fibbia superiore / Presilla superior / Fivela superior / Spänne pä hjässan Top straps / Obere Bänder / Sangles supérieures / Cinghie superiori / Correas superiores / Correias superiores / De övre remmarna Back straps / Hintere Bänder / Sang les arrières / Cinghie posteriori / Correas posteriores / Correias traseiras / De bakre remmarna 2006 ResMed Ltd. ResMed Mirage Swift™ II NASAL PILLOWS SYSTEM Thank you for choosing ResMed's Mirage Swift II Nasal Pillows System. The nasal pillows system is light, flexible and quiet. It is designed to minimize contact with your face, thus ensuring that you feel comfortable during therapy. This user guide provides you with the information you need for the correct use of your system. Intended Use The Mirage Swift II is intended for multipatient use by adult patients (>30 kg) prescribed continuous positive airway pressure or bilevel therapy for use in home, hospitals or clinics. Note: The Mirage Swift II is not compatible for use with ResMed AutoSet CS™ 2 and VPAP™ Adapt SV devices. Medical Information Note: The Mirage Swift II does not contain latex, PVC, or DEHP materials. If you have ANY reaction to any part of the system, discontinue use and consult your sleep therapist. Warnings and Cautions • This system should be used only with flow generators (CPAP or bilevel) recommended by your physician or respiratory therapist. It should not be used unless the flow generator is turned on and operating properly. The vent holes should never be blocked. Explanation of the Warning: Flow generators are intended to be used with special interfaces with connectors which have vent holes (vent holes are located on the frame—see section A on the illustrations sheet) or separate exhalation devices to allow continuous flow of air out of the interface. When the flow generator is turned on and functioning properly, new air from the flow generator flushes the exhaled air out through the attached exhalation 1 English port. However, when the flow generator is not operating (eg, power failure), not enough fresh air will be provided through the system, and exhaled air may be rebreathed. In this situation, remove the Mirage Swift II immediately. • The exhaust vent flow is lower at lower system pressures (see section "Technical Specifications" for Pressure-Flow Curve details). If the system pressure during expiration is too low, there may not be enough exhaust vent flow to completely flush the air delivery hose of exhaled air before the start of the next inspiration. • Discontinue using the Mirage Swift II if you frequently experience nasal irritation, and consult your physician. • The Mirage Swift II must be cleaned and disinfected/sterilized if it is used between patients. See section "Cleaning the Mirage Swift II between Patients" for details. • If oxygen is used with the flow generator, the oxygen flow must be turned off when the flow generator is not operating. Explanation of the Warning: When the flow generator is not in operation, and the oxygen flow is left on, oxygen delivered into the ventilator tubing may accumulate within the flow generator enclosure. Oxygen accumulated in the flow generator enclosure will create a risk of fire. This warning applies to most types of flow generators. • Please refrain from smoking while oxygen is in use. Note: At a fixed flow rate of supplemental oxygen flow, the inhaled oxygen concentration will vary, depending on the pressure settings, patient breathing pattern,...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category