Login:
Votes - 1, Average rating: 5 ( )

User manual Campbell Hausfeld, model IN730800AV

Manafacture: Campbell Hausfeld
File size: 5.21 mb
File name: c90b0369-cae9-4229-94c0-b3c4faf907b3.pdf
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


f. Always wear eye protection. g. Always wear hearing protection when using the tool. Prolonged exposure to high intensity noise is able to cause hearing loss. h. Do not attach the hose or tool to your body. Attach the hose to the structure to reduce the risk of loss of balance if the hose shifts. i. Always assume that the tool contains fasteners. Do not point the tool toward yourself or anyone whether it contains fasteners or not. j. Do not nail on top of another nail. This is able to cause the nail to be deflected and hit someone, or cause the tool to react and result in a risk of injury to persons. Always remain in a firmly balanced position when using or handling the tool. Avoid long extended periods of work with the tool. Stop using the tool if you feel pain in hands or arms. Tool Components and Specifications Exhaust • REqUIRES: 2.5 SCFM @ 90 psi @ five 16d FPM • AIR INlET: 1/4 inch NPT • NAIL SIZE RANGE: 6d to 16d • WEIGHT: 1 lb, 1 oz Nail guide • LENGTH: 3-1/2inches • HEIGHT: 4 inches • WIDTH: 2-1/4 inches • MAXIMUM PRESSURE: 125 psi • PRESSURE RANGE: 50 - 125 psi Nose Air inlet Operating Instructions Important Safety Instructions (Continued) TOOL USE AND CARE a. Use clamps or another practical way to secure and support the workpiece to a stable platform. Holding the work by hand or against the body is unstable and is able to lead to loss of control. b. Do not force the tool. Use the correct tool for the application. The correct tool will do the job better and safer at the rate for which the tool is designed. c. Do not use the tool if the switch does not turn the tool on or off. Any tool that cannot be controlled with the switch is dangerous and must be repaired. Never attach air line while the nailer is loaded as the immediate valve resetting that may occur may forcefully eject the nail. First connect air line, then load. d. Disconnect the tool from the air source before making adjustments, doing tool maintenance, clearing jams, leaving work area, or unloading the tool. Such precautionary measures reduce the risk of injury to persons. e. Store the tool when it is idle out of reach of children and other untrained persons. A tool is dangerous in the hands of untrained users. f. Maintain the tool with care. Keep a cutting tool sharp and clean. A properly maintained tool, with sharp cutting edges reduces the risk of binding and is easier to control. g. Check for misalignment or binding of moving parts, breakage of parts, and any other condition that affects the tool’s operation. If damaged, have the tool serviced before using. Many accidents are caused by poorly maintained tools. There is a risk of bursting if the tool is damaged. h. Use only those fasteners listed in the Accessories section of this manual. Fasteners not identified for use with this tool by the tool manufacturer are able to result in a risk of injury to persons or tool damage when used in this tool. i. Selecting an appropriate tool actuation system, taking into consideration the work application for which the tool is used. Never use gasoline or other flammable liquids to clean the tool. Never use the tool in the presence of flammable liquids or gases. Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury. Do not remove, tamper with, or otherwise cause the trigger lock or trigger to become inoperable. Do not operate any tool which has been modified in a like fashion. Death or serious personal injury could result. on the tool magazine and body. Dropping or throwing the tool can result in damage that will make the tool Always disconnect the tool from the power source when unattended, performing any maintenance or repair, clearing a jam, or moving the tool to a new location. Always fit tool with a fitting or hose coupling on or near the tool in such a manner that all compressed air in the tool is discharged at the time the fitting or hose coupling is disconnected. Do not use a check valve or any other fitting which allows air to remain in the tool. Death or serious personal injury could occur. Never place hands or any other body parts in the fastener discharge area of the tool. The tool might eject a fastener and could result in death or serious personal injury. Never carry the tool by the air hose or pull the hose to move the tool or a compressor. Keep hoses away from heat, oil and sharp edges. Replace any hose that is damaged, weak or worn. Personal injury or tool damage could occur. PN001000 Always assume the tool contains fasteners. Respect the tool as a working implement; no horseplay. Always keep others at a safe distance from the work area in case of accidental discharge of fasteners. Do not point the tool toward yourself or anyone whether it contains fasteners or not. Accidental triggering of the tool could result in death or serious personal injury. Do not drive a fastener on top of other fasteners. The fastener could glance and cause death or a serious puncture...

Other models in this manual:
Other Tools - PN001000 (5.21 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category