Login:
Votes - 2, Average rating: 4.5 ( )

User manual Philips, model SPO2 M1194AN

Manafacture: Philips
File size: 2 mb
File name:
Language of manual:ruplsvitentresfrdebgetslnlhuptskdaficslvltro
Free link for this manual available at the bottom of the page



manual abstract


Each Special Edition A- Series sensor can replace its similarly numbered A-series sensor; i.e. M1191ANL can replace M1191AL; M1192AN can replace M1192A; M1193AN can replace M1193A; M1194AN can replace M1194A; and M1195AN can replace M1195A. A-Series Sensors B-Series Sensors 2Special Edition A-Series Sensors Adult Pediatric Infant Neonate Finger Ear Finger Ear 3Finger Toe 3Hand Foot M1191A M1191B N/A • 1M1191AL 1M1191BL 1M1191ANL • M1192A N/A M1192AN • M1193A N/A M1193AN • • M1194A N/A M1194AN • • M1195A N/A M1195AN • • 1These sensors have a Longer 3m (versus standard 2m) attached cable. 2These sensors extend compatibility to Philips brand OxiMax® compatible instruments. 3Preferred application sites for M1193A and M1195A sensors. 1 Intended Use Philips reusable SpO2 sensors are for multi-patient use, when continuous non-invasive arterial oxygen saturation and pulse rate monitoring are required. Accessories Supplied with Sensors • M1627A Adult Wristband: Supplied only with adult finger sensors to secure sensor cable to back of adult patient’s hand and wrist. • Instructions for Use: Describes sensor models, patient applications, Warnings against improper use, and specifications. Accessories Available for Separate Purchase • M1940A Adapter Cable: 8-pin (round female) to 12-pin (round male) adapter cable. Adapts 8-pin sensor connector to 12-pin instrument jack. Extends sensor cable length by 2m. DO NOT USE with M1191AL, M1191ANL, M1191BL sensors. • M1941A Extension Cable: 8-pin (round female) to 8-pin (round male) extension cable. Extends sensor cable length by 2m. DO NOT USE with M1191AL, M1191ANL, M1191BL sensors. Definition of Product Symbols Adult Pediatric Adult Finger Infant/Neo Hand Adult/Pediatric Ear Infant Neonate (Neo) Pediatric/Infant Finger Infant Toe Infant/Neo Foot Caution, See Documentation Prescription Use Only Storage Temp Contains no Latex 2 Warnings • These sensors are for use only with Philips/Agilent/HP instruments. Before using, verify the combination of instrument/sensor is specified in the instrument’s user documentation (e.g. Instructions for Use); otherwise patient injury may result. • Pulse oximetry measurements are statistically distributed. Two-thirds of all pulse oximetry measurements can be expected to fall within the stated accuracy (refer to Specifications later in this IFU for stated sensor accuracy). • Connect the sensor only to the SpO2 connection or the SpO2 adapter cable of the oximeter. • Do not reuse the sensor on a different patient until it has been disinfected. The sensor can be reused on the same patient for the patient’s entire stay. • At elevated ambient temperatures, patient skin could be severely burned after prolonged sensor application at sites that are not well perfused. To prevent this condition, be sure to check patient application sites frequently. All listed sensors operate without risk of exceeding 41o C on the skin if the initial skin temperature does not exceed 35o C. • Be sure to apply the se...

Other models in this manual:
Other Tools - SPO2 M1191A (2 mb)
Other Tools - SPO2 M1191AL (2 mb)
Other Tools - SPO2 M1191ANL (2 mb)
Other Tools - SPO2 M1191B (2 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category