Login:
Votes - 1, Average rating: 5 ( )

User manual Omega Engineering, model Series Micro Flow Sensor FP-5060

Manafacture: Omega Engineering
File size: 270.31 kb
File name: M2579.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


8 TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz France: 11, rue Jacques Cartier, 78280 Guyancourt, France TEL: +33 (0)1 61 37 29 00 FAX: +33 (0)1 30 57 54 27 Toll Free in France: 0800 466 342 e-mail: sales@omega.fr Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de United Kingdom:2 One Omega Drive, River Bend Technology Centre ISO 9002 Certifi ed Northbank, Irlam, Manchester M44 5BD United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-48 e-mail: sales@omega.co.uk It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certifi cation. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications. page 2 OMEGA FP-5060 Series Micro Flow Sensor OMEGA FP-5060 Series Micro-Flow Sensors SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Do not install/service without following installation instructions (see sensor manual). 4. Wear safety goggles and faceshield during installation/service. 5. Do not alter product construction. 6. Failure to follow safety instructions could result in severe personal injury! 1. Instrument Wiring OMEGA FP-90 Series, FPM-5500, FPM-9020A OMEGA FP-5060 Series Sensor Black (5 to 24 VDC) Red (Signal out) Shield (DC return) Blk Power Red Freq. input Shld Gnd Other Instrument Input Gnd. 10 k. + 5 to 24 VDC- Black Shield Red Other instrument Note: A 10 k. pull-up resistor is required as shown, ifnot provided internal to the instrument. Contact OMEGA Technical Support for assistance. Technical Notes: • Use 2-conductor twisted-pair shielded cable for cable splices up to 300 m (1000 ft) max. • Maintain cable shield through cable splice. • Route sensor cable away from AC power lines. • AUX power required when used with any OMEGA FP90 Series Flow Transmitter. 2. Recommended Sensor Position 0° 30°30° Recommended Vertical mounting mounting angles not recommended Technical Notes: • Horizontal surface mount (±30 °) recommended for optimum performance. • Suitable for clean fluids only. Suspended solids will cause mechanical failure. • . in. NPT or ISO 7/1 - R. (male) port connections • NEMA 4X/IP65 splashproof enclosure OMEGA FP-5060 Series Micro Flow Sensor page 3 3. Surface Mount Instructions 2 Remove sensor then use correct screws for panel material. #6 or M3 metric screws recommended 1 Mounting surface 120° Mounting surface (top), Mounting surface (side) 68 mm (2.68 in.) bolt circle 4. Fitting Installation CAUTION: • Maximum pipe fitting torque: 10 ft - lbs (13 N m). • DO NOT overtighten. Failure to observe torque specification may permanently damage sensor ports. FP-5060 Pipe Pipe fitting Pipe fitting Pipe Sealant Technical Notes: • Compatible fittings (customer supplied): Female union (shown), reducer, or hose barb type. • Always apply thread sealant to sensor port threads to prevent leakage. 5. Calibration The K-Factors listed below represent the number of pulses the sensor will generate for each engineering unit of fluid which passes. They are listed in U.S. gallons, liters and mL by sensor model: Sensor Model PULSES PER U.S. GAL PULSES PER LITER PULSES PER mL FP-5061 9950 2629 2.629 FP-5062 9950 2629 2.629 FP-5063 3160 834.9 0.835 FP-5064 3160 834.9 0.835 page 4 OMEGA FP-5060 Series Micro Flow Sensor 6. Specifi cations General Flow range: 5061 and 5062: 0.11 to 2.6 lpm (0.03 to 0.7 gpm) 5063 and 5064: 1.13 to 12.11 lpm (0.3 to 3.2 gpm) Linearity: ±1.2% of full range Repeatability: ±0.5% of full range Connections: . in. NPT (male) or ISO 7/1 - R. (male) Cable length: 8 m (25 ft.), can splice up to 300 m (1000 ft.) max. Cable type: 2-conductor twisted pair w/shield (Belden 8451) Weight: 250 g (9.6 oz.) Wetted Materials • Sensor body and cover: 40% glass filled Polyphenylene Sulfide • Rotor: PEEK, natural, unfilled • Rotor O-ring: Viton® • Cover O-ring: Viton® Electrical Supply voltage: 5 to 24 VDC, regulated Supply current: 10 mA max. Output type: Open...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category