Login:
Votes - 2, Average rating: 4 ( )

User manual Elkay, model 4595

Manafacture: Elkay
File size: 38.04 kb
File name: 95cdd49b-a7c9-4ae4-c926-6b404c398c39.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


After installation, leave these instructions with the Fountain for future reference. IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. General Installation Tips 1. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/4" IPS. Contractor to supply waste trap and service stop valve in accordance with local code. 2. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being connected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor, color, or sediment problems. 3. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and the cooler. Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a positive stop, approximately 3/4" (See Fig. 6). DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT. 4. These products are designed to operate on 20 psig to 105 psig supply line pressure. If inlet pressure is above 105 psig, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psig or higher than 105 psig is not covered by warranty. Page 1 97460C (Rev. SIB - 6/06) 4595_FTN FIG. 1 Installation Instructions 1. This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure must be capable of supporting 300 lb. load on fountain. 2. Refer to rough-in for plumbing. 3. Install shut-off valve on water supply. (Valve not furnished). 4. Locate and install fountain using 3/8" minimum screws or bolts. (Screws or bolts not furnished). CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI. 5. Connect water supply and fountain drain. Water connection and drain must comply with local codes. 6. Turn on water supply and check all connections for leaks. 97460C (Rev. SIB - 6/06) Page 2 4595_FTN 17 6 18 2 24 See Fig. 3 9-A 11 22 16 16 16 15 12 1 2023 3 1 14 24 23 22 5 2 2 9-B 6 3 2 5 16 18 21 16 BUBBLER DETAIL FIG. 2 4 10 8 STREAM HEIGHT ADJUSTMENT: Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove items 7 and 8 (See Fig. 3) and adjust screw on item 19. 7 19 Clockwise adjustment will raise stream and counter-clockwise adjustment will lower stream. For best adjustment, stream should hit basin approx. 6-1/2" from bubbler. 13 FIG. 3 FIG. 4 Page 3 97460C (Rev. SIB - 6/06) 4595_FTN 4595_FTN4595_FTN TROUBLE SHOOTING AND MAINTENANCE PARTS LIST ITEM NO. PARTNO. DESCRIPTION 1 100147140560 Drain Gasket 2 100322740560 Bubbler Gasket 3 101570540560 Drain Gasket 4 15005C Regulator Retaining Nut 5 15013C Bubbler Tube Assy. 6 170705042830 Basin 7 40048C Button 840089C Cover Nut 9 -A400942308640 Bubbler 9 -B 98287C Bubbler Assembly 10 40169C Hex Nut 1-5/16-20UN 11 40250C Tailpipe 1-1/4" x 5-3/8" 12 45476C Drain Tube 13 50986C Regulator Holder 14 55913C Drain Adapter 15 55996C In-Line Strainer 16 56092C Poly Tubing (Cut To Length) 17 56121C Drain Elbow 1-1/4" 18 600985551640 Drain Plug Assy. 19 61313C Regulator 20 66346C Drain Tube 21 70682C Tee - 1/4 22 70683C Union - 1/4 23 75588C Slip Joint Nut 1-1/4" 24 75589C Gasket Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file or small diameter wire. CAUTION: DO NOT file or cut orifice material. Stream Regulator: If orifice is clean, regulate flow as in "STREAM HEIGHT ADJUSTMENT" instructions on page 3. If replacement is necessary, see parts list for correct regulator part number. Actuation of Quick Connect Water Fittings: Fountain is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Fig. 5). To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4". FIG. 5 1/4" O.D. TUBE WATER INLET TO FOUNTAIN FIG. 6 NOTE: WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP (NOT FURNISHED) 3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY PRINTED IN U.S.A. FOR ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category