|
manual abstract
NOTE: Before installing the unit have the following wires installed: 1. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box. 2. A 2 conductor wire with ground (3 wires total) from the main switch wall box to the junction box on the unit. NOTE: Use a single pole, single throw (on/off) wall switch that is rated for a minimum of 15 amps. 120 VOLT INSTALLATIONS 1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. (see figure 2 on page 3) 2. Ensure that the switch is in the 120 volt position. (115 is printed on switch) 3. Loosen the screw securing the junction box cover and remove the cover. 4. Remove the knockouts (if necessary) or use the provided cable clamp. 5. Pull out the four wires marked L1, L2, N, and G. (black, red, white and green) 6. Connect the (black) L1 wire from the unit to the (black) L1 wire from the main power wall switch using a wire connector (not supplied). 7. Connect the other end of the (black) L1 wire to the L1 terminal of the main power wall switch. 8. Connect the (red) L2 wire from the unit and the (white) Neutral wire from the unit to the (white) Neutral wire of the main power wall switch by using a wire connector (not supplied). 9. Connect the other end of the (white) Neutral wire to the (white) Neutral wire from the power supply panel by using a wire connector (not supplied). 10.Connect the (green) Ground wire from the unit to the (green) Ground wire of the main power wall switch by using a wire connector (not supplied). 11.Connect the (black) L1 wire from the power supply to the L1 terminal of the main power wall switch. 12.Secure the 2 remaining (green) Ground wires with a ground screw in the main switch wall box. 13.Ensure that all connections are tight. 14.Insert all the wiring of the main power wall switch into the main switch wall box. 15.Insert all the wiring back into the unit and secure with a cable clamp. 120 VOLT MAIN WALL SWITCH WIRING DIAGRAM 10 FIREPLACE JUNCTION BOX 120 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH GROUND - G MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NO HEAT INSTALLATION NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 3. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box. 4. A 2 conductor wire with ground (3 wires total) from the main switch wall box to the junction box on the unit. NOTE: Use a single pole, single throw (on/off) wall switch that is rated for a minimum of 15 amps. 120 VOLT INSTALLATIONS 16.Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. (see figure 2 on page 3) 17.Ensure that the switch is in the 120 volt position. (115 is printed on switch) 18.Loosen the screw securing the junction box cover and remove the cover. 19.Remove the knockouts (if necessary) or use the provided cable clamp. 20.Pull out the four wires marked L1, L2, N, and G. (black, red, white and green) 21.Connect the (black) L1 wire from the unit to the (black) L1 wire from the main power wall switch using a wire connector (not supplied). 22.Connect the other end of the (black) L1 wire to the L1 terminal of the main power wall switch. 23. Install a wire nut on the red L2 (wire nut not included). 24.Connect the (white) Neutral wire from the unit to the (white) Neutral wire of the main power wall switch by using a wire connector (not supplied). 25.Connect the other end of the (white) Neutral wire to the (white) Neutral wire from the power supply panel by using a wire connector (not supplied). 26.Connect the (green) Ground wire from the unit to the (green) Ground wire of the main power wall switch by using a wire connector (not supplied). 27.Connect the (black) L1 wire from the power supply to the L1 terminal of the main power wall switch. 28.Secure the 2 remaining (green) Ground wires with a ground screw in the main switch wall box. 29.Ensure that all connections are tight. 30.Insert all the wiring of the main power wall switch into the main switch wall box. 31.Insert all the wiring back into the unit and secure with a cable clamp. 120 VOLT MAIN WALL SWITCH WIRING DIAGRAM NO HEAT INSTALLATION FIREPLACE JUNCTION BOX 120 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH GROUND - G Wire Nut 12 SECTION E: HEATER WALL SWITCH AND WALL THERMOSTAT WIRING OPTIONS HEATER WALL SWITCH WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the heater switch wall box to the junction box on the unit. NOTE: Use a heater wall switch (on/off) that is rated for a minimum of 15 amps. 120 / 240 VOLT INSTALLATIONS 1. L...
Other models in this manual:Other Home Accessories - BF33ST/DX (807 kb)